--- layout: documentation title: PS15Z - ZWave --- {% include base.html %} # PS15Z Plug-In Appliance Module This describes the Z-Wave device *PS15Z*, manufactured by *Linear Corp* with the thing type UID of ```linear_ps15z_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![PS15Z product image](https://www.cd-jackson.com/zwave_device_uploads/352/352_default.jpg) The PS15Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/352) to improve the documentation. ## Channels The following table summarises the channels available for the PS15Z -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Scene Number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ## Device Configuration The following table provides a summary of the 1 configuration parameters available in the PS15Z. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 104 | Mode | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 104: Mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Flash Mode | | 1 | ON/OFF Operation | The manufacturer defined default value is ```0``` (Flash Mode). This parameter has the configuration ID ```config_104_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_PROTECTION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/352/linear-ps15z2-instruction-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/352).