--- layout: documentation title: 39349 - ZWave --- {% include base.html %} # 39349 Smart Outlet This describes the Z-Wave device *39349*, manufactured by *Honeywell* with the thing type UID of ```honeywell_39349_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![39349 product image](https://www.cd-jackson.com/zwave_device_uploads/901/901_default.jpg) The 39349 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview * One Z-Wave remote controlled outlet, one always-ON outlet * Remote ON/OFF control via the Z-Wave controller/network * Manual ON/OFF control with the manual/program button * Blue LED indicates outlet location in a dark room ### Inclusion Information Put controller into inclusion mode, then press and release the program button to add it to the network. ### Exclusion Information Put controller into exclusion mode, then press and release the program button to remove it from the network. ## Channels The following table summarises the channels available for the 39349 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Scene Number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ## Device Configuration The following table provides a summary of the 1 configuration parameters available in the 39349. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | LED light | Configuration of LED light | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 3: LED light Configuration of LED light The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED ON when Load is OFF, LED OFF when ON | | 1 | LED ON when Load is ON, LED OFF when load is OFF | | 2 | LED always OFF | The manufacturer defined default value is ```1``` (LED ON when Load is ON, LED OFF when load is OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 39349 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ### Group 2: Basic Set, local load Supports Basic Set and is controlled with the local load Association group 2 supports 5 nodes. ### Group 3: Basic Set, ON/OFF button Supports Basic Set and is controlled by pressing the On or Off button Supports Basic Set and is controlled by pressing the On or Off button Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [Manual](https://www.cd-jackson.com/zwave_device_uploads/901/39349-HQSG-v1.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/901).