--- layout: documentation title: HS1MS-Z - ZWave --- {% include base.html %} # HS1MS-Z Smart Motion Sensor This describes the Z-Wave device *HS1MS-Z*, manufactured by *[Heiman Technology Co. Ltd](http://www.heimantech.com/)* with the thing type UID of ```heiman_hs1msz_00_000```. The device is in the category of *Motion Detector*, defining Motion sensors/detectors. The HS1MS-Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. The HS1MS-Z does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information. ## Overview The smart motion sensor is designed to detect motion indoors. When the smart motion sensor detects people or animals moving, it will report the information thru Z-Wave protocol. ### Inclusion Information * Press button on the back 3 times, Green LED is Blinking 3 times within 1 second. * If Inclusion Process is successful, Green LED will turn off. ### Exclusion Information * Press back button 3 times quickly. * If Exclusion Process is successful, Green LED is Blinking 6 times, then remove battery from HS1MS-Z. ### Wakeup Information The HS1MS-Z does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device. * Wake up Notification is transmitted every 24 hours by default. * Wake up Notification is transmitted after Notification Report is Transmitted. ## Channels The following table summarises the channels available for the HS1MS-Z -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Binary Sensor | sensor_binary | Door | Switch | | Alarm (burglar) | alarm_burglar | Door | Switch | | Battery Level | battery-level | Battery | Number | ### Binary Sensor Indicates if a sensor has triggered. The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Triggered | | OFF | Untriggered | ### Alarm (burglar) Indicates if the burglar alarm is triggered. The ```alarm_burglar``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The HS1MS-Z supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_BINARY_V2| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ALARM_V4| Linked to BASIC| | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_WAKE_UP_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/736).