--- layout: documentation title: ZW3101 - ZWave --- {% include base.html %} # ZW3101 Lamp Module This describes the Z-Wave device *ZW3101*, manufactured by *Jasco Products* with the thing type UID of ```ge_zw3101_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![ZW3101 product image](https://www.cd-jackson.com/zwave_device_uploads/44/44_default.jpg) The ZW3101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Plug in lamp module with on/off/dimming control on front of device. ### Inclusion Information 1. Plug in ZW3101 2. Place controller in inclusion mode 3. Press button on face of ZW3101 ### Exclusion Information 1. Place controller in exclusion mode 2. Press button on front of ZW3101 ## Channels The following table summarises the channels available for the ZW3101 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Dimmer | switch_dimmer | DimmableLight | Dimmer | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ## Device Configuration The following table provides a summary of the 8 configuration parameters available in the ZW3101. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 5 | Ignore Start-Level (Receiving) | This dimmer will start dimming from its current level. | | 7 | On/Off Command Dim Step | Indicates how many levels the dimmer will change for each dimming step. | | 8 | On/Off Command Dim Rate | Dim Rate | | 9 | Local Control Dim Step | Indicates how many levels the dimmer will change for each dimming step. | | 10 | Local Control Dim Rate | Local Control Dim Rate | | 11 | ALL ON/ALL OFF Dim Step | Indicates how many levels the dimmer will change for each dimming step. | | 12 | ALL ON/ALL OFF Dim Rate | | | 29 | Load Sensing | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 5: Ignore Start-Level (Receiving) This dimmer will start dimming from its current level. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes | The manufacturer defined default value is ```0``` (No). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: On/Off Command Dim Step Indicates how many levels the dimmer will change for each dimming step. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: On/Off Command Dim Rate Dim Rate Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Local Control Dim Rate Local Control Dim Rate Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: ALL ON/ALL OFF Dim Rate Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 29: Load Sensing The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Load sensing is disabled | | 1 | Load sensing is enabled | The manufacturer defined default value is ```0``` (Load sensing is disabled). This parameter has the configuration ID ```config_29_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_NODE_NAMING_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/44/zw3103.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/44).