--- layout: documentation title: GE 28169 - ZWave --- {% include base.html %} # GE 28169 Plug in Smart Switch This describes the Z-Wave device *GE 28169*, manufactured by *Jasco Products* with the thing type UID of ```ge_ge28169_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![GE 28169 product image](https://www.cd-jackson.com/zwave_device_uploads/595/595_default.jpg) The GE 28169 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Z-wave controlled AC outlet for standard incandescent lighting, CFL/LEDs, fans or small appliances. Must not exceed 600 watts (Incandescent); 1800W (15A) Resistive or ½ HP Motor ### Inclusion Information Put controller into inclusion mode, single press and release the manual/program button on the smart switch to include it in the network ### Exclusion Information Put controller into exclusion mode, single press and release the manual/program button on the smart switch to exclude it from the network ## Channels The following table summarises the channels available for the GE 28169 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Scene Number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The GE 28169 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | ### Documentation Links * [Manual Multilanguage](https://www.cd-jackson.com/zwave_device_uploads/595/28169-1-EnFrSp-QSG.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/595).