--- layout: documentation title: 45606 - ZWave --- {% include base.html %} # 45606 2-Way Dimmer Switch This describes the Z-Wave device *45606*, manufactured by *Jasco Products* with the thing type UID of ```ge_45606_00_000```. The 45606 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/41) to improve the documentation. ## Channels The following table summarises the channels available for the 45606 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Dimmer | switch_dimmer | DimmableLight | Dimmer | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the 45606. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | Night Light | Defines the behavior of the blue LED. | | 4 | Invert Switch | Change the top of the switch to OFF and the bottom of the switch to ON. | | 5 | Ignore Start-Level (Receiving) | This dimmer will start dimming from its current level. | | 7 | On/Off Command Dim Step | Indicates how many levels the dimmer will change for each dimming step. | | 8 | On/Off Command Dim Rate | Sets the rate at which the dimmer changes the light level. | | 9 | Local Control Dim Step | Indicates how many levels the dimmer will change for each dimming step. | | 10 | Local Control Dim Rate | Sets the dim rate | | 11 | ALL ON/ALL OFF Dim Step | Indicates how many levels the dimmer will change for each dimming step. | | 12 | ALL ON/ALL OFF Dim Rate | Sets the dim rate for the all on/off command | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 3: Night Light Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED on when switch is OFF | | 1 | LED on when switch is ON | | 2 | LED always off | The manufacturer defined default value is ```0``` (LED on when switch is OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Invert Switch Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes | The manufacturer defined default value is ```0``` (No). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Ignore Start-Level (Receiving) This dimmer will start dimming from its current level. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes | The manufacturer defined default value is ```0``` (No). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: On/Off Command Dim Step Indicates how many levels the dimmer will change for each dimming step. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: On/Off Command Dim Rate Sets the rate at which the dimmer changes the light level. This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Local Control Dim Step Indicates how many levels the dimmer will change for each dimming step. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Local Control Dim Rate Sets the dim rate This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dimmer will change. Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: ALL ON/ALL OFF Dim Step Indicates how many levels the dimmer will change for each dimming step. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: ALL ON/ALL OFF Dim Rate Sets the dim rate for the all on/off command This value indicates in 10 millisecond resolution, how often the dim level will change. For example, if you set this parameter to 1, then every 10ms the dim level will change. If you set it to 255, then every 2.55 seconds the dimmer will change. Values in the range 1 to 255 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/41/45606-Manual-Eng.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/41).