--- layout: documentation title: FGS212 - ZWave --- {% include base.html %} # FGS212 Relay Switch 1x2.5kW This describes the Z-Wave device *FGS212*, manufactured by *[Fibargroup](http://www.fibaro.com/)* with the thing type UID of ```fibaro_fgs212_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![FGS212 product image](https://www.cd-jackson.com/zwave_device_uploads/114/114_default.jpg) The FGS212 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Remotely Controlled Relay Switch of Fibaro System is designed to operate in a wall switch box or in locations where the control of an electric device is needed. ### Inclusion Information Fibaro Switch must be placed within the range of Home Center controller, as adding mode requires direct communication with the controller. Find key no. 1 which allows to switch circuit 1 on, in accordance with the diagram During the installation it is recommended to use a momentary key connected to S1. Add Fibaro Switch to the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes. The controller indicates when the device is correctly added to the network. **CAUTION** Fibaro Switch cancels the "learning" mode after key no. 1 is pressed once. Therefore, pressing key no. 1 four times will not add the devices to the network. The same applies to push-button B. ### Exclusion Information Find key no. 1 which allows to switch circuit 1 on, in accordance with the diagram During removing it is recommended to use a momentary key connected to S1. Remove Fibaro Switch from the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes. The controller indicates when the device is correctly removed from the network. ## Channels The following table summarises the channels available for the FGS212 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Switch 1 | switch_binary1 | Switch | Switch | | Switch 2 | switch_binary2 | Switch | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 13 configuration parameters available in the FGS212. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF | | 3 | Override OFF-delay | Forced auto off period | | 4 | Relay 1: OFF-delay time (100ms steps) | Automatic turning off relay 1 after set time ... | | 6 | Separation of association sending (key 1) | Sending commands to control devices assigned ... | | 13 | Inputs behaviour | Assigns bistable key status to the device status. | | 14 | Inputs Button/Switch configuration | Binary inputs type configuration | | 15 | Dimmer/Roller shutter control | Enable/Disable operation of dimmer or roller shutter devices ... | | 16 | Saving state before power failure | Saving state before power failure | | 30 | Relay 1: Response to General Alarm | | | 31 | Relay 1: Response to Water Flood Alarm | | | 32 | Relay 1: Response to Smoke, CO, CO2 Alarm | | | 33 | Relay 1: Response to Temperature Alarm | | | 39 | ALARM FLASHING alarm time | Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame | | | Wakeup Interval | Sets the interval at which the device will accept commands from the controller | | | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | ALL ON disabled / ALL OFF disabled | | 1 | ALL ON disabled / ALL OFF active | | 2 | ALL ON active / ALL OFF disabled | | 255 | ALL ON active / ALL OFF active | The manufacturer defined default value is ```255``` (ALL ON active / ALL OFF active). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 3: Override OFF-delay Forced auto off period If Parameter 4 states an auto off period, this parameter enable the possibility to turn off the relay with a button push. Default value 0 disallow turn off with a button push during the auto off interval. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Turn off with push button disabled | | 1 | Turn off with push button enabled | The manufacturer defined default value is ```0``` (Turn off with push button disabled). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Relay 1: OFF-delay time (100ms steps) Automatic turning off relay 1 after set time ... Default: 0 (Auto off disabled). In 100ms increments. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 6: Separation of association sending (key 1) Sending commands to control devices assigned ... to 1-st association group (key no. 1) - Also see param #15 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Map status to all devices in group 1 | | 1 | Map OFF status to all devices in group 1 ... | | 2 | Map OFF status to all devices in group 1 ... | The manufacturer defined default value is ```0``` (Map status to all devices in group 1). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 13: Inputs behaviour Assigns bistable key status to the device status. Available configuration parameters: 0 - [On / Off] device changes status on key status change. 1 - Device status depends on key status: ON when the key is ON, OFF when the key is OFF The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Toggle | | 1 | Follow switch contact (closed=ON, open=OFF) | The manufacturer defined default value is ```0``` (Toggle). This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Inputs Button/Switch configuration Binary inputs type configuration The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Mono-stable input (button) | | 1 | Bi-stable input (switch) | The manufacturer defined default value is ```1``` (Bi-stable input (switch)). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Dimmer/Roller shutter control Enable/Disable operation of dimmer or roller shutter devices ... enabling this option allows the user to dim lighting/shut roller by associating Dimmer/Roller Shutter Controller and holding or double press of double switch (only mono-stable switch). The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable Dimmer/Roller shutter control | | 1 | Enable Dimmer/Roller shutter control | The manufacturer defined default value is ```0``` (Disable Dimmer/Roller shutter control). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 16: Saving state before power failure Saving state before power failure The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | State NOT saved at pwr failure, outputs set ... | | 1 | State saved at pwr failure, outputs are set to ... | The manufacturer defined default value is ```1``` (State saved at pwr failure, outputs are set to ...). This parameter has the configuration ID ```config_16_1``` and is of type ```INTEGER```. ### Parameter 30: Relay 1: Response to General Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING - relay will turn ON and OFF ... | The manufacturer defined default value is ```3``` (ALARM FLASHING - relay will turn ON and OFF ...). This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ### Parameter 31: Relay 1: Response to Water Flood Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING - relay will turn ON and OFF ... | The manufacturer defined default value is ```2``` (Alarm relay OFF). This parameter has the configuration ID ```config_31_1``` and is of type ```INTEGER```. ### Parameter 32: Relay 1: Response to Smoke, CO, CO2 Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING - relay will turn ON and OFF ... | The manufacturer defined default value is ```3``` (ALARM FLASHING - relay will turn ON and OFF ...). This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ### Parameter 33: Relay 1: Response to Temperature Alarm The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION - no response to alarm frames | | 1 | Alarm relay ON | | 2 | Alarm relay OFF | | 3 | ALARM FLASHING - relay will turn ON and OFF ... | The manufacturer defined default value is ```1``` (Alarm relay ON). This parameter has the configuration ID ```config_33_1``` and is of type ```INTEGER```. ### Parameter 39: ALARM FLASHING alarm time Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_39_2``` and is of type ```INTEGER```. ### Wakeup Interval The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications. This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances. Note that this setting does not affect the devices ability to send sensor data, or notification events. This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```. ### Wakeup Node When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact. This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The FGS212 supports 3 association groups. ### Group 1: Switch 1 Association group 1 supports 16 nodes. ### Group 2: Switch 2 Association group 2 supports 16 nodes. ### Group 3: Controller Updates Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_WAKE_UP_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| ### Documentation Links * [User Manual V1.01](https://www.cd-jackson.com/zwave_device_uploads/114/FGS-212-EN-A-v1-01.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/114).