--- layout: documentation title: FGR221 - ZWave --- {% include base.html %} # FGR221 Roller Shutter Controller This describes the Z-Wave device *FGR221*, manufactured by *[Fibargroup](http://www.fibaro.com/)* with the thing type UID of ```fibaro_fgr221_00_000```. The device is in the category of *Blinds*, defining Roller shutters, window blinds, etc.. The FGR221 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/132) to improve the documentation. ## Channels The following table summarises the channels available for the FGR221 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Blinds control | blinds_control | Blinds | Rollershutter | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Blinds control Provides start / stop control of blinds. The ```blinds_control``` channel supports the ```Rollershutter``` item and is in the ```Blinds``` category. ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the FGR221. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF | | 10 | Control key #2 behaviour | Turning off the shutter positioning function | | 14 | Inputs Button/Switch configuration | Binary inputs type configuration | | 20 | Dimmer/Roller shutter control | Options for changing parameter 1-99, default 16 | | 30 | General Alarm | set for shutter no. 1 | | 31 | Alarm of flooding with water | set for relay the shutter | | 32 | Smoke, CO, CO2 Alarm. | Set for the roller shutter. | | 33 | Temperature Alarm | set for roller shutter | | 41 | Scene activation functionality | Only valid for the 1.9 version of FGR221. | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Enable/Disable ALL ON/OFF Activate/Deactive ALL ON/OFF The following option values may be configured -: | Value | Description | |--------|-------------| | -1 | ALL ON active / ALL OFF active | | 0 | ALL ON disabled/ ALL OFF disabled | | 1 | ALL ON disabled/ ALL OFF active | | 2 | ALL ON active / ALL OFF disabled | The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 10: Control key #2 behaviour Turning off the shutter positioning function The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Turning on the shutter positioning function - Default | | 1 | Turning off the shutter positioning function | The manufacturer defined default value is ```0``` (Turning on the shutter positioning function - Default). This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 14: Inputs Button/Switch configuration Binary inputs type configuration The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Mono-stable input (button) | | 1 | Bi-stable input (switch) | | 2 | Single Mono-stable switch | The manufacturer defined default value is ```0``` (Mono-stable input (button)). This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 20: Dimmer/Roller shutter control Options for changing parameter 1-99, default 16 Values in the range 0 to 255 may be set. The manufacturer defined default value is ```16```. This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 30: General Alarm set for shutter no. 1 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION | | 1 | OPEN SHUTTER ALARM | | 2 | CLOSED SHUTTER ALARM | The manufacturer defined default value is ```2``` (CLOSED SHUTTER ALARM). This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ### Parameter 31: Alarm of flooding with water set for relay the shutter The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION | | 1 | OPEN SHUTTER ALARM | | 2 | CLOSED SHUTTER ALARM | The manufacturer defined default value is ```0``` (DEACTIVATION). This parameter has the configuration ID ```config_31_1``` and is of type ```INTEGER```. ### Parameter 32: Smoke, CO, CO2 Alarm. Set for the roller shutter. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION | | 1 | OPEN SHUTTER ALARM | | 2 | CLOSED SHUTTER ALARM | The manufacturer defined default value is ```1``` (OPEN SHUTTER ALARM). This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ### Parameter 33: Temperature Alarm set for roller shutter The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | DEACTIVATION | | 1 | OPEN SHUTTER ALARM | | 2 | CLOSED SHUTTER ALARM | The manufacturer defined default value is ```1``` (OPEN SHUTTER ALARM). This parameter has the configuration ID ```config_33_1``` and is of type ```INTEGER```. ### Parameter 41: Scene activation functionality Only valid for the 1.9 version of FGR221. The device offers the possibility of sending commands compatible with Command class scene activation. Information is sent to devices assigned to association group no. 3. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivation of functionality - Default | | 1 | Activation of functionality | The manufacturer defined default value is ```0``` (Deactivation of functionality - Default). This parameter has the configuration ID ```config_41_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The FGR221 supports 3 association groups. ### Group 1: Group 1 Association group 1 supports 16 nodes. ### Group 2: Group 2 Association group 2 supports 16 nodes. ### Group 3: Controller Updates Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_BASIC_WINDOW_COVERING_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1| | ### Documentation Links * [User Manual (2.1-2.3)](https://www.cd-jackson.com/zwave_device_uploads/132/FGR221-Roller-Shutter-en-2-1-2-3.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/132).