--- layout: documentation title: LPM-15 - ZWave --- {% include base.html %} # LPM-15 Appliance module This describes the Z-Wave device *LPM-15*, manufactured by *Evolve* with the thing type UID of ```evolve_lpm15_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![LPM-15 product image](https://www.cd-jackson.com/zwave_device_uploads/580/580_default.jpg) The LPM-15 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Evolve Plug-in Appliance Module is a component of the Evolve lighting control system and is fully scene capable. The Appliance Module is plugged into any standard grounded AC wall outlet, and the appliance or other device is then plugged into the module. Once connected, the appliance/device can be easily turned ON or OFF remotely via the Z-Wave network. This device is compatible with Z-Wave security systems and can handle a maximum of the following loads: * Incandescent – 600W, 120 VAC * Resistive – 15 amps (1800 watts), 120 VAC * Motor – ½ H.P., 120 VAC This Plug-in Appliance Module is designed to work with other Evolve enabled devices. Evolve nodes of other types can be included in the network and will also act as repeaters to increase the range of the network. As part of a Z-Wave network, the LPM-15 will also act as a wireless repeater to ensure that commands intended for another device in the network are received. This is useful when the device would otherwise be out of the radio range of the wireless controller. ### Inclusion Information 1. Start a search for new z-wave binding items via the add things interface 2. Press the button on the front of the unit to include Note: will work with inclusion set to network-wide. Factory reset procedure: 1. Unplug device and wait 15 seconds 2. Plug device in and immediately press the front button twice (the two presses must occur within 20 seconds of plugging in the unit. ### Exclusion Information 1. Place controller in exclude mode 2. Press button on front of device ## Channels The following table summarises the channels available for the LPM-15 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Scene Number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ## Device Configuration The following table provides a summary of the 2 configuration parameters available in the LPM-15. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | Night Light | Defines the behavior of the blue LED; default has LED on when switch is off. | | 4 | Invert Switch | Change the top of the switch to OFF and the bottom of the switch to ON. | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 3: Night Light Defines the behavior of the blue LED; default has LED on when switch is off. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED on when switch is OFF | | 1 | LED on when switch is ON | | 2 | LED always off | The manufacturer defined default value is ```0``` (LED on when switch is OFF). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Invert Switch Change the top of the switch to OFF and the bottom of the switch to ON. Note: If you invert the switches and also install the product upside down, remember the load will now be controlled by the right, not the left switch. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | No | | 1 | Yes | The manufacturer defined default value is ```0``` (No). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_PROTECTION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Evlovle LPM-15 Product Overview](https://www.cd-jackson.com/zwave_device_uploads/580/LPM-15.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/580).