--- layout: documentation title: MT02646 - ZWave --- {% include base.html %} # MT02646 Home Control Metering Plug This describes the Z-Wave device *MT02646*, manufactured by *Devolo* with the thing type UID of ```devolo_mt02646_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![MT02646 product image](https://www.cd-jackson.com/zwave_device_uploads/1/1_default.png) The MT02646 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Home Control Smart Metering Plug can be plugged into any wall outlet in the home. It enhances every connected device with useful functions, such as time-controlled enabling and disabling or power monitoring ### Inclusion Information Push the front button three times rapidly within 2 seconds. ### Exclusion Information Push the front button three times rapidly within 2 seconds. ## Channels The following table summarises the channels available for the MT02646 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (power factor) | meter_powerfactor | Energy | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Reset the total power consumption | meter_reset | Energy | Switch | | Alarm | alarm_general | Door | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (power factor) Indicates the instantaneous power factor. The ```meter_powerfactor``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Reset the total power consumption Reset the meter. The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the MT02646. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Watt Meter Report Period | multiples of 5s | | 2 | KWH Meter Report Period | number of 10 minute intervals | | 3 | Threshold of current for Load Caution | 1300*0.01A = 13A | | 4 | Threshold of KWh for Load Caution | load caution threshold | | 5 | Restore switch state mode | Restore switch state mode. | | 6 | Mode of switch off function | Mode of switch off function. | | 7 | LED indication mode | Restore switch state mode. | | 8 | Auto off timer | Auto off timer. 0 will disable the auto off function. | | 9 | RF off command mode | RF off command mode | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Watt Meter Report Period multiples of 5s Enable automatic interval in seconds reporting with an interval of 5s * the value. Set to 0 will disable the autoreporting function. The following option values may be configured, in addition to values in the range 0 to 32767 -: | Value | Description | |--------|-------------| | 0 | Disable | The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_1_2``` and is of type ```INTEGER```. ### Parameter 2: KWH Meter Report Period number of 10 minute intervals Enable automatic interval in minutes reporting with an interval of 10min * the value. Set to 0 will disable the autoreporting function. The following option values may be configured, in addition to values in the range 0 to 32767 -: | Value | Description | |--------|-------------| | 0 | Disable | The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Threshold of current for Load Caution 1300*0.01A = 13A Values in the range 10 to 1300 may be set. The manufacturer defined default value is ```1300```. This parameter has the configuration ID ```config_3_2``` and is of type ```INTEGER```. ### Parameter 4: Threshold of KWh for Load Caution load caution threshold Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set. The manufacturer defined default value is ```10000```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: Restore switch state mode Restore switch state mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Switch OFF after power on | | 1 | resume previous state | | 2 | Switch ON after power on | The manufacturer defined default value is ```1``` (resume previous state). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Mode of switch off function Mode of switch off function. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | SWITCH OFF commands received are ignored. | | 1 | SWITCH OFF commands received are honored. | The manufacturer defined default value is ```1``` (SWITCH OFF commands received are honored.). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: LED indication mode Restore switch state mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | The LED follows the state of the switch. | | 2 | LED off with load ON | | 3 | Flash mode | The manufacturer defined default value is ```1``` (The LED follows the state of the switch.). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Auto off timer Auto off timer. 0 will disable the auto off function. The following option values may be configured, in addition to values in the range 0 to 255 -: | Value | Description | |--------|-------------| | 0 | Disable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_8_2``` and is of type ```INTEGER```. ### Parameter 9: RF off command mode RF off command mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | SWITCH ALL OFF turns Switch OFF | | 1 | Ignore ALL OFF | | 2 | If ALL OFF is received, turn ON if it is OFF | | 3 | SWITCH ALL OFF turns Switch ON | The manufacturer defined default value is ```0``` (SWITCH ALL OFF turns Switch OFF). This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The MT02646 supports 1 association group. ### Group 1: Reports Grouping 1 includes, SWITCH\_BINARY\_REPORT, METER\_REPORT, ALARM\_REPORT. Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [English User Manual](https://www.cd-jackson.com/zwave_device_uploads/1/Manual-devolo-Home-Control-Metering-Plug-com.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/1).