--- layout: documentation title: ZW096 - ZWave --- {% include base.html %} # ZW096 Smart Switch 6 This describes the Z-Wave device *ZW096*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw096_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![ZW096 product image](https://www.cd-jackson.com/zwave_device_uploads/63/63_default.jpg) The ZW096 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Aeon Labs Smart Switch is a Z-Wave power binary switch device based on Z-Wave enhanced 232 slave library V6.51.06. Its surface has the Smart RGB LEDs on, which can be used for indicating the output load status, the strength of wireless signal. You can also configure its indication colour according to your favour. It can be included and operated in any Z-wave network with other Z-wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It is also a security Z-wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade. As soon as Smart Switch is removed from a z-wave network it will be restored into default factory setting. Reset Smart Switch to factory Default: 1. Make sure the Smart Switch has been connected to the power supply. 2. Press and hold the Z-wave button for 20 seconds. 3. If holding time more than one second, the LED will blink faster and faster. If holding time more than 20seconds, the green LED will be on for 2 seconds and then remain colorful gradient status, it indicates reset success, otherwise please repeat step 2. Note: 1. This procedure should only be used when the primary controller is inoperable. 2. Reset Smart Switch to factory default settings will: sets the Smart Switch to not in Z-Wave network state; delete the Association setting, power measure value, Scene Configuration Settings and restore the Configuration setting to the default ### Inclusion Information Add Smart Switch into a z-wave network: 1. Insert the Smart Switch to power socket, The purple LED will be colorful gradient status. 2. Let the primary controller into inclusion mode (If you don’t know how to do this, refer to its manual). 3. Press the Action button. 4. If the inclusion success, Smart Switch LED will be solid. Otherwise, the LED will remain colorful gradient status, in which you need to repeat the process from step 2. ### Exclusion Information Remove Smart Switch from a z-wave network: 1. Insert the Smart Switch to power socket, The Smart Switch LED will be solid. 2. Let the primary controller into remove mode (If you don’t know how to do this, refer to its manual). 3. Press the Action button. 4. If the remove is successful, Smart Switch LED will blink slowly. If Smart Switch LED still be solid, please repeat the process from step 2. ## Channels The following table summarises the channels available for the ZW096 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (watts) | meter_watts | Energy | Number | | Reset Meter | meter_reset | Energy | Switch | | Color | color_color | | Color | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Reset Meter Reset the meter. The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category. ### Color The color channel allows to control the color of a light. It is also possible to dim values and switch the light on and off. The ```color_color``` channel supports the ```Color``` item. ## Device Configuration The following table provides a summary of the 26 configuration parameters available in the ZW096. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 3 | Current overload protection enable | Current overload protection enable | | 20 | Output load after re-power | Configure the output load status after re‐power | | 33 | RGB LED color testing | Set the RGB LED color value for testing. | | 80 | Enable send to associated devices | Enable to send notifications to Group 1 | | 81 | Configure LED state | Configure the state of the LED | | 83 | Color in night light mode | | | 83 | Blue night light color value | Blue night light color value | | 83 | Green night light color value | Green night light color value | | 83 | Red night light color value | Configure the RGB value when it is in Night light mode | | 84 | Color in energy mode | | | 84 | Green brightness in energy mode (%) | Green brightness in energy mode (%) | | 84 | Yellow brightness in energy mode (%) | Yellow brightness in energy mode (%) | | 84 | Red brightness in energy mode (%) | Red brightness in energy mode (%) | | 90 | Enable items 91 and 92 | Enables/disables parameter 91 and 92 | | 91 | Wattage Threshold | minimum change in wattage to trigger | | 92 | Wattage Percent Change | minimum change in wattage percent | | 100 | Set 101‐103 to default. | Set 101‐103 to default. | | 101 | Values to send to group 1 | Which reports need to send in Report group 1 | | 102 | Values to send to group 2 | Which reports need to send in Report group 2 | | 103 | Values to send to group 3 | Which reports need to send in Report group 3 | | 110 | Set 111‐113 to default. | Set 111‐113 to default. | | 111 | Time interval for sending to group 1 | Group 1 automatic update interval | | 112 | Time interval for sending to group 2 | Group 2 automatic update interval | | 113 | Time interval for sending to group 3 | Group 3 automatic update interval | | 252 | Configuration Locked | Enable/disable Configuration Locked (0 =disable, 1 = enable). | | 255 | RESET | Reset the device to defaults | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 3: Current overload protection enable Current overload protection enable Current Overload Protection. Load will be closed when the Current overrun (US: 15.5A, other country: 16.2A) and the time more than 2 minutes (0=disabled, 1=enabled). The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (disabled). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 20: Output load after re-power Configure the output load status after re‐power Configure the output load status after re-power on (0=last status, 1=always on, 2=always off) The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | last status | | 1 | always on | | 2 | always off | The manufacturer defined default value is ```0``` (last status). This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 33: RGB LED color testing Set the RGB LED color value for testing. Value1: Reserved Value2: Red value Value3: Green value Value4: Blue value Values in the range 0 to 0 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_33_4_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 80: Enable send to associated devices Enable to send notifications to Group 1 Enable to send notifications to associated devices (Group 1) when the state of Micro Switch’s load changed (0=nothing, 1=hail CC, 2=basic CC report). The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | nothing | | 1 | hail CC | | 2 | basic CC report | The manufacturer defined default value is ```0``` (nothing). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 81: Configure LED state Configure the state of the LED Configure the state of LED when it is in 3 modes below: * 0= The LED will follow the status (on/off) of its load (Energy mode). * 1= When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action (momentary indicate mode). * 2= Night light mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED follows load | | 1 | LED follows load for 5 seconds | | 2 | Night light mode | The manufacturer defined default value is ```0``` (LED follows load). This parameter has the configuration ID ```config_81_1``` and is of type ```INTEGER```. ### Parameter 83: Color in night light mode This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 16777215 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_83_3``` and is of type ```INTEGER```. ### Parameter 83: Blue night light color value Blue night light color value Value for parameter 83, night light blue color Values in the range 0 to 255 may be set. The manufacturer defined default value is ```221```. This parameter has the configuration ID ```config_83_3_000000FF``` and is of type ```INTEGER```. ### Parameter 83: Green night light color value Green night light color value Green color value for parameter 83, night light mode. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```160```. This parameter has the configuration ID ```config_83_3_0000FF00``` and is of type ```INTEGER```. ### Parameter 83: Red night light color value Configure the RGB value when it is in Night light mode Configure the RGB value when it is in Night light mode. Value1: Red color value Value2: Green color value Value3: Blue color value defaults: Value1=0xDD Value2=0xA0 Value3=0xDD Values in the range 0 to 255 may be set. The manufacturer defined default value is ```221```. This parameter has the configuration ID ```config_83_3_00FF0000``` and is of type ```INTEGER```. ### Parameter 84: Color in energy mode This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 16777215 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_84_3``` and is of type ```INTEGER```. ### Parameter 84: Green brightness in energy mode (%) Green brightness in energy mode (%) Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/momentary indicate mode. Value1: green color value. Value2: yellow color value. Value3: red color value. Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_84_3_000000FF``` and is of type ```INTEGER```. ### Parameter 84: Yellow brightness in energy mode (%) Yellow brightness in energy mode (%) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_84_3_0000FF00``` and is of type ```INTEGER```. ### Parameter 84: Red brightness in energy mode (%) Red brightness in energy mode (%) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_84_3_00FF0000``` and is of type ```INTEGER```. ### Parameter 90: Enable items 91 and 92 Enables/disables parameter 91 and 92 Enables/disables parameter 91 and 92 below (1=enabled, 0=disabled). The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```1``` (enabled). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Wattage Threshold minimum change in wattage to trigger The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent (Valid values 0- 60000). Values in the range 0 to 60000 may be set. The manufacturer defined default value is ```25```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Wattage Percent Change minimum change in wattage percent The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent (Valid values 0-100). Values in the range 0 to 100 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 100: Set 101‐103 to default. Set 101‐103 to default. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | False | | 1 | True | The manufacturer defined default value is ```0``` (False). This parameter has the configuration ID ```config_100_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 101: Values to send to group 1 Which reports need to send in Report group 1 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Voltage | | 2 | Current | | 4 | Wattage | | 8 | kWh | | 15 | All Values | The manufacturer defined default value is ```4``` (Wattage). This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Values to send to group 2 Which reports need to send in Report group 2 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Voltage | | 2 | Current | | 4 | Wattage | | 8 | kWh | | 15 | All Values | The manufacturer defined default value is ```8``` (kWh). This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Values to send to group 3 Which reports need to send in Report group 3 The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Voltage | | 2 | Current | | 4 | Wattage | | 8 | kWh | | 15 | All Values | The manufacturer defined default value is ```0``` (Nothing). This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 110: Set 111‐113 to default. Set 111‐113 to default. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | False | | 1 | True | The manufacturer defined default value is ```0``` (False). This parameter has the configuration ID ```config_110_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Parameter 111: Time interval for sending to group 1 Group 1 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF). Default value is 3 Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Time interval for sending to group 2 Group 2 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF). Default value is 600 Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Time interval for sending to group 3 Group 3 automatic update interval The time interval of sending Report group 1 (Valid values 0x01-0xFFFFFFFF). Default value is 600 Note: Only up to 0x7fffffff is currently supported Values in the range 1 to 2147483647 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 252: Configuration Locked Enable/disable Configuration Locked (0 =disable, 1 = enable). Enable/disable Configuration Locked (0 =disable, 1 =enable). The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (disabled). This parameter has the configuration ID ```config_252_1``` and is of type ```INTEGER```. ### Parameter 255: RESET Reset the device to defaults Reset configuration set up to default setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_255_1_wo``` and is of type ```INTEGER```. This is a write only parameter. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZW096 supports 2 association groups. ### Group 1: Group 1 load notification type (lifeline) When the state of Smart Switch (turn on/off the load ) is changed: 1. Set Configuration parameter 80 to 0 Reserved (Default). 2. Set Configuration parameter 80 to 1 Send Hail CC. 3. Set Configuration parameter 80 to 2: Send the Basic Report. Association group 1 supports 5 nodes. ### Group 2: Group 2 forwarding basic set (retransmit) Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Smart Switch receives the Basic Set, Switch Binary Set commands from main controller. Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_SWITCH_COLOR_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/63/3-Smart-Switch-6.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/63).