--- layout: documentation title: DSC24 - ZWave --- {% include base.html %} # DSC24 Smart Energy Switch G2 This describes the Z-Wave device *DSC24*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc24_00_000```. The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there. ![DSC24 product image](https://www.cd-jackson.com/zwave_device_uploads/76/76_default.jpg) The DSC24 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/76) to improve the documentation. ## Channels The following table summarises the channels available for the DSC24 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Scene Number | scene_number | | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Reset Meter | meter_reset | Energy | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel supports the ```Number``` item. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Reset Meter Reset the meter. The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category. ## Device Configuration The following table provides a summary of the 16 configuration parameters available in the DSC24. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Multilevel Sensor Report Content | | | 2 | Make SES blink | | | 80 | Automatic Notifications | Enables automatic notifications to associated devices whenever there is a state change | | 90 | Enable Parameter 91 | Enables/disables parameter 91 and 92 below | | 91 | Minimum change in wattage | The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent. | | 92 | Minimum change in wattage % | The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent. | | 100 | Set 100 to 103 to default | | | 101 | Group 1 report | | | 102 | Group 2 report | | | 103 | Group 3 report | | | 110 | Set 111 to 113 to default | | | 111 | Interval group 1 | The time interval of sending Report group 1 | | 112 | Interval group 1 | The time interval of sending Report group 2 | | 113 | Interval group 1 | The time interval of sending Report group 3 | | 254 | Device Tag | | | 255 | Device Reset | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Multilevel Sensor Report Content Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Make SES blink Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 80: Automatic Notifications Enables automatic notifications to associated devices whenever there is a state change The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Hail | | 2 | Basic CC Report | The manufacturer defined default value is ```0``` (Nothing). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 90: Enable Parameter 91 Enables/disables parameter 91 and 92 below The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```0``` (Disable). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Minimum change in wattage The value here represents minimum change in wattage (in terms of wattage) for a REPORT to be sent. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Minimum change in wattage % The value here represents minimum change in wattage percent (in terms of percentage) for a REPORT to be sent. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 100: Set 100 to 103 to default The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Reset | The manufacturer defined default value is ```0``` (Reset). This parameter has the configuration ID ```config_100_1``` and is of type ```INTEGER```. ### Parameter 101: Group 1 report The following option values may be configured -: | Value | Description | |--------|-------------| | 2 | Multisensor Report | | 4 | Meter Report (Watts) | | 8 | Meter Report (kWh) | The manufacturer defined default value is ```8``` (Meter Report (kWh)). This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Group 2 report The following option values may be configured -: | Value | Description | |--------|-------------| | 2 | Multisensor Report | | 4 | Meter Report (Watts) | | 8 | Meter Report (kWh) | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Group 3 report The following option values may be configured -: | Value | Description | |--------|-------------| | 2 | Multisensor Report | | 4 | Meter Report (Watts) | | 8 | Meter Report (kWh) | The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 110: Set 111 to 113 to default The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Reset | The manufacturer defined default value is ```0``` (Reset). This parameter has the configuration ID ```config_110_1``` and is of type ```INTEGER```. ### Parameter 111: Interval group 1 The time interval of sending Report group 1 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval group 1 The time interval of sending Report group 2 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval group 1 The time interval of sending Report group 3 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 254: Device Tag Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_254_2``` and is of type ```INTEGER```. ### Parameter 255: Device Reset The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Reset | The manufacturer defined default value is ```0``` (Reset). This parameter has the configuration ID ```config_255_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC24 supports 2 association groups. ### Group 1: Status Reports Association group 1 supports 5 nodes. ### Group 2: Send Reports on blind state change Send Reports on blind state change Association group 2 supports 10 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Product Manual](https://www.cd-jackson.com/zwave_device_uploads/76/Aeotec-Z-Wave-Plug-In-Smart-Switch-5-Product-Manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/76).