--- layout: documentation title: DSC19 - ZWave --- {% include base.html %} # DSC19 Micro Smart Energy Illuminator G2 This describes the Z-Wave device *DSC19*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc19_00_000```. ![DSC19 product image](https://www.cd-jackson.com/zwave_device_uploads/79/79_default.jpg) The DSC19 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview The Aeon Labs Micro Smart Dimmer (2nd Edition) is a scene multilevel switch device based on Z‐wave enhanced slave library V4.55.00. ### Inclusion Information Include Smart Dimmer into an existing Z‐Wave network: 1. Install Micro Smart Dimmer, and connect Micro Smart Dimmer to an AC‐input power source. 2. Let the primary controller of existing Z‐Wave network into inclusion mode (If you don’t know how to do this, refer to its manual). 3. Press the Z‐Wave button. 4. If the Learning failed, please repeat the process from step 2. ### Exclusion Information Remove Smart Switch from an existing Z‐Wave network: 1. Installed Micro Smart Dimmer, and connect Micro Smart Dimmer to an AC‐ input power source. 2. Let the primary controller of existing Z‐Wave network into remove mode (If you don’t know how to do this, refer to its manual). 3. Press the Z‐Wave button. 4. If the remove failed, please repeat the process from step 2 ## Channels The following table summarises the channels available for the DSC19 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Dimmer | switch_dimmer | DimmableLight | Dimmer | | Electric meter (kWh) | meter_kwh | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric Meter (kVah) | meter_kvah | Energy | Number | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric Meter (kVah) Indicates the energy consumption (kVAh). The ```meter_kvah``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 14 configuration parameters available in the DSC19. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Make Micro Smart Dimmer 2nd Edition Blink | The LSB defines the total time the device need to blink. | | 3 | Current Overload Protection | Load will be closed when current more that 2.7A and time more than 2 minutes | | 13 | Enable/Disable CRC16 encapsulation | Parameter to Enable/Disable CRC16 encapsulation | | 80 | Notification on Status Change | Send load notification to associated devices | | 90 | Sending of a Report triggered by minimal change of value. | Automated sending of a Report triggered by minimal change of value. | | 91 | Minimum Change to send Report (Watt) | The value represents the minimum change in Wattage for a Report to be sent. | | 92 | Minimum Change to send Report (%) | The minimum change in Watage Percent for a report to be sent. | | 101 | Reports for Group 1 | Which reports need to send automatically in timing intervals for group 1 | | 102 | Reports for Group 2 | Which reports need to send automatically in timing intervals for group 2 | | 103 | Reports for Group 3 | Which reports need to send automatically in timing intervals for group 3 | | 111 | Interval to send out reports of group 1 | | | 112 | Interval to send out reports of group 2 | | | 113 | Interval to send out reports of group 3 | | | 120 | Turn External Button Mode | Parameter to set External button type | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 2: Make Micro Smart Dimmer 2nd Edition Blink The LSB defines the total time the device need to blink. This is a double byte value. The LSB defines the total time the device need to blink. The value if set in seconds. The MSB defines the on/off interval of the blinking. The unit is 0.1 s. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Current Overload Protection Load will be closed when current more that 2.7A and time more than 2 minutes The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivate | | 1 | Activate | The manufacturer defined default value is ```0``` (Deactivate). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 13: Enable/Disable CRC16 encapsulation Parameter to Enable/Disable CRC16 encapsulation Values in the range 0 to 255 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 80: Notification on Status Change Send load notification to associated devices Parameter to Enable to send notification to associated devices (Group 1) when the state of Micro Smart Dimmer's load changed The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deactivate | | 1 | Hail CC Sent | | 2 | Basic CC Report Sent | The manufacturer defined default value is ```0``` (Deactivate). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 90: Sending of a Report triggered by minimal change of value. Automated sending of a Report triggered by minimal change of value. Parameter to Enable/Disable automated sending of a Report triggered by minimal change of value. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Deavtivate | | 1 | Activate | The manufacturer defined default value is ```0``` (Deavtivate). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Minimum Change to send Report (Watt) The value represents the minimum change in Wattage for a Report to be sent. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```25```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Minimum Change to send Report (%) The minimum change in Watage Percent for a report to be sent. The value represents the minimum change in Watage Percent for a report to be sent. Values in the range 0 to 255 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 101: Reports for Group 1 Which reports need to send automatically in timing intervals for group 1 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Reports for Group 2 Which reports need to send automatically in timing intervals for group 2 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Reports for Group 3 Which reports need to send automatically in timing intervals for group 3 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: KWH=8, Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 111: Interval to send out reports of group 1 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```3```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval to send out reports of group 2 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval to send out reports of group 3 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 120: Turn External Button Mode Parameter to set External button type The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Momentary Button Mode | | 1 | 2 State Switch Mode | | 2 | 3 Way Switch Mode | The manufacturer defined default value is ```255```. This parameter has the configuration ID ```config_120_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC19 supports 2 association groups. ### Group 1: Target for automatic meter reports Association group 1 supports 5 nodes. ### Group 2: Target for automatic reports According to the info in de nodeXX.xml file, this group doesn't exist for this device. - It doesn't work. Association group 2 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V2| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/79/z-wave-aeon-labs-micro-smart-energy-illuminator-engineering-specification-1-.pdf) * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/79/Micro-20Smart-20Energy-20Illuminator-20G2-1-.pdf) * [Z-Wave Protocol Implementation Conformance Statement](https://www.cd-jackson.com/zwave_device_uploads/79/ZC08-13030005.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/79).