--- layout: documentation title: DSC14 - ZWave --- {% include base.html %} # DSC14 Micro Motor Controller This describes the Z-Wave device *DSC14*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc14_00_000```. The DSC14 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/289) to improve the documentation. ## Channels The following table summarises the channels available for the DSC14 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Switch | switch_binary | Switch | Switch | | Dimmer | switch_dimmer | DimmableLight | Dimmer | ### Switch Switch the power on and off. The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category. ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ## Device Configuration The following table provides a summary of the 12 configuration parameters available in the DSC14. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Type of Sensor Report | | | 2 | Blinking Behavior | | | 80 | Notification on Status Change | | | 90 | Disable automated reporting | | | 91 | Minimum Change to send Report (Watt) | | | 92 | Minimum Change to send Report (%) | | | 101 | reports to send automatically | | | 102 | Which reports to send automatically to group 2 | | | 103 | Which reports to send automatically to group 3 | | | 111 | Interval to send out reports of group 1 | | | 112 | Interval to send out reports of group 2 | | | 113 | Interval to send out reports of group 3 | | ### Parameter 1: Type of Sensor Report The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Power | | 1 | Voltage | The manufacturer defined default value is ```0``` (Power). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Blinking Behavior Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 80: Notification on Status Change The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Nothing | | 1 | Hail | | 2 | Basic CC Report | The manufacturer defined default value is ```0``` (Nothing). This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```. ### Parameter 90: Disable automated reporting Disables Function of automated sending of a Report triggered by minimal change of value. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```. ### Parameter 91: Minimum Change to send Report (Watt) Values in the range 0 to 32000 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```. ### Parameter 92: Minimum Change to send Report (%) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```. ### Parameter 101: reports to send automatically The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Which reports to send automatically to group 2 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Which reports to send automatically to group 3 The value is a combination number made up of the sum of the values for the individual parameters. The parameters have the values: Wattage=4, Current=2, Voltage=1. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 111: Interval to send out reports of group 1 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval to send out reports of group 2 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval to send out reports of group 3 Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSC14 supports 1 association group. ### Group 1: Group 1 Status Reports Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/289).