--- layout: documentation title: DSB28 - ZWave --- {% include base.html %} # DSB28 Home Energy Meter G2 This describes the Z-Wave device *DSB28*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsb28_00_000```. ![DSB28 product image](https://www.cd-jackson.com/zwave_device_uploads/85/85_default.jpg) The DSB28 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/85) to improve the documentation. ## Channels The following table summarises the channels available for the DSB28 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Electric meter (watts) | meter_watts | Energy | Number | | Electric meter (amps) | meter_current | Energy | Number | | Electric meter (volts) | meter_voltage | Energy | Number | | Electric meter (kWh) | meter_kwh | Energy | Number | | Reset Meter | meter_reset | Energy | Switch | | Electric meter (watts) 1 | meter_watts1 | Energy | Number | | Electric meter (amps) 1 | meter_current1 | Energy | Number | | Electric meter (volts) 1 | meter_voltage1 | Energy | Number | | Electric meter (kWh) 1 | meter_kwh1 | Energy | Number | | Electric meter (watts) 2 | meter_watts2 | Energy | Number | | Electric meter (amps) 2 | meter_current2 | Energy | Number | | Electric meter (volts) 2 | meter_voltage2 | Energy | Number | | Electric meter (kWh) 2 | meter_kwh2 | Energy | Number | | Electric meter (watts) 3 | meter_watts3 | Energy | Number | | Electric meter (volts) 3 | meter_voltage3 | Energy | Number | | Electric meter (amps) 3 | meter_current3 | Energy | Number | | Electric meter (kWh) 3 | meter_kwh3 | Energy | Number | ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Reset Meter Reset the meter. The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category. ### Electric meter (watts) 1 Indicates the instantaneous power consumption. The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 1 Indicates the instantaneous current consumption. The ```meter_current1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 1 Indicates the instantaneous voltage. The ```meter_voltage1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 1 Indicates the energy consumption (kWh). The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) 2 Indicates the instantaneous power consumption. The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 2 Indicates the instantaneous current consumption. The ```meter_current2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 2 Indicates the instantaneous voltage. The ```meter_voltage2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 2 Indicates the energy consumption (kWh). The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) 3 Indicates the instantaneous power consumption. The ```meter_watts3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 3 Indicates the instantaneous voltage. The ```meter_voltage3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 3 Indicates the instantaneous current consumption. The ```meter_current3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 3 Indicates the energy consumption (kWh). The ```meter_kwh3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 17 configuration parameters available in the DSB28. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Reverse clamping | If the reverse clamping pliers, negative power is detected. | | 3 | Selective Reporting | Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. (Bit 0: Whole HEM , Bit 1:Clamp 1, Bit 2:Clamp 2, Bit 3:Clamp 3) | | 4 | Current Threshold - Whole HEM | Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000) | | 5 | Current Threshold - Clamp 1 | Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000) | | 6 | Current Threshold - Clamp 2 | Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000) | | 7 | Current Threshold - Clamp 3 | Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000) | | 8 | Percent Change - Whole HEM | Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100) | | 9 | Percent Change - Clamp 1 | Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100) | | 10 | Percent Change - Clamp 2 | Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100) | | 11 | Percent Change - Clamp 3 | Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100) | | 101 | Which reports need to send automatically for group 1 | 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W | | 102 | Which reports need to send automatically for group 2 | 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W | | 103 | Which reports need to send automatically for group 3 | 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W | | 111 | Interval to send out reports of group 1 | | | 112 | Interval to send out reports of group 2 | | | 113 | Interval to send out reports of group 3 | | | 255 | Factory Reset | Reset all settings to factory defaults | ### Parameter 2: Reverse clamping If the reverse clamping pliers, negative power is detected. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | Enabled | The manufacturer defined default value is ```0``` (Disabled). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Selective Reporting Enable selective reporting only when power change reaches a certain threshold or percentage set in 4-11 below. This is used to reduce network traffic. (Bit 0: Whole HEM , Bit 1:Clamp 1, Bit 2:Clamp 2, Bit 3:Clamp 3) Values in the range 0 to 16 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Current Threshold - Whole HEM Threshold change in wattage to induce a automatic report (Whole HEM). (Valid values 0-60000) Values in the range 0 to 60000 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: Current Threshold - Clamp 1 Threshold change in wattage to induce a automatic report (Clamp 1). (Valid values 0-60000) Values in the range 0 to 60000 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_5_2``` and is of type ```INTEGER```. ### Parameter 6: Current Threshold - Clamp 2 Threshold change in wattage to induce a automatic report (Clamp 2). (Valid values 0-60000) Values in the range 0 to 60000 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_6_2``` and is of type ```INTEGER```. ### Parameter 7: Current Threshold - Clamp 3 Threshold change in wattage to induce a automatic report (Clamp 3). (Valid values 0-60000) Values in the range 0 to 60000 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_7_2``` and is of type ```INTEGER```. ### Parameter 8: Percent Change - Whole HEM Percentage change in wattage to induce a automatic report (Whole HEM). (Valid values 0-100) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Percent Change - Clamp 1 Percentage change in wattage to induce a automatic report (Clamp 1). (Valid values 0-100) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Parameter 10: Percent Change - Clamp 2 Percentage change in wattage to induce a automatic report (Clamp 2). (Valid values 0-100) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Percent Change - Clamp 3 Percentage change in wattage to induce a automatic report (Clamp 3). (Valid values 0-100) Values in the range 0 to 100 may be set. The manufacturer defined default value is ```50```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 101: Which reports need to send automatically for group 1 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W Values in the range 0 to 1061109568 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```. ### Parameter 102: Which reports need to send automatically for group 2 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W Values in the range 0 to 1061109568 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```. ### Parameter 103: Which reports need to send automatically for group 3 1 -> Battery Report2 -> MultiSensor Report for the whole device4 -> Meter Report for Watt for the whole device8 -> Meter Report for kWh for the whole device256 -> Meter Report for Watt for clamp 1512 -> Meter Report for W Values in the range 0 to 1061109568 may be set. The manufacturer defined default value is ```8```. This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```. ### Parameter 111: Interval to send out reports of group 1 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```. ### Parameter 112: Interval to send out reports of group 2 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```. ### Parameter 113: Interval to send out reports of group 3 Values in the range 1 to 2678400 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```. ### Parameter 255: Factory Reset Reset all settings to factory defaults If you upgrade firmware and are seeing crazy or impossible numbers, reset to factory then reconfigure unit.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Do nothing | | 1 | RESET TO FACTORY DEFAULTS | The manufacturer defined default value is ```0``` (Do nothing). This parameter has the configuration ID ```config_255_1_wo``` and is of type ```INTEGER```. This is a read only parameter. This is a write only parameter. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The DSB28 supports 3 association groups. ### Group 1: Group 1 Association group 1 supports 5 nodes. ### Group 2: Group 2 Association group 2 supports 5 nodes. ### Group 3: Group 3 Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_METER_V3| Linked to BASIC| | COMMAND_CLASS_CRC_16_ENCAP_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_METER_V3| Linked to BASIC| #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_METER_V3| Linked to BASIC| #### Endpoint 3 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_METER_V3| Linked to BASIC| ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/85/z-wave-aeon-labs-clamp-power-meter-hem3-engineering-specification.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/85).