Updated external content (Jenkins build 990)

pull/1847/head
openHAB Build Server 2022-06-18 03:35:17 +00:00
parent ea9d032312
commit ac784b8cd9
15 changed files with 563 additions and 40 deletions

File diff suppressed because one or more lines are too long

View File

@ -5,6 +5,7 @@ title: LIVISI SmartHome - Bindings
type: binding
description: "The binding integrates the [LIVISI (RWE/innogy) SmartHome](https://www.livisi.de) system into openHAB."
since: 3x
logo: images/addons/livisismarthome.png
install: manual
---

View File

@ -44,23 +44,11 @@ The following table summarises the channels available for the TILTZWAVE2 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
| Tamper Alarm | alarm_tamper | alarm_tamper | | Switch |
| Door State [Deprecated]| sensor_door | sensor_door | Door | Contact |
| Binary Sensor | sensor_door | sensor_door | Door | Contact |
| Tamper Alarm Cover Off | alarm_tamper | alarm_tamper | | Switch |
| Battery Level | battery-level | system.battery_level | Battery | Number |
### Tamper Alarm
Indicates if the tamper alarm is triggered.
The ```alarm_tamper``` channel is of type ```alarm_tamper``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Door State [Deprecated]
### Binary Sensor
Indicates if the door/window is open or closed.
The ```sensor_door``` channel is of type ```sensor_door``` and supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -72,7 +60,17 @@ The following state translation is provided for this channel to the ```Contact``
| OPEN | Open |
| CLOSED | Closed |
**Note:** This channel is marked as deprecated so should not be used.
### Tamper Alarm Cover Off
Indicates if the tamper alarm is triggered.
The ```alarm_tamper``` channel is of type ```alarm_tamper``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
@ -182,6 +180,7 @@ Association group 2 supports 5 nodes.
* [English User Manual](https://opensmarthouse.org/zwavedatabase/139/reference/Ecolink-TILTZWAVE2-ECO-manual-rev1.pdf)
* [Updated Manual](https://opensmarthouse.org/zwavedatabase/139/reference/Tilt-ZWave-Plus-Manual-R1-04-021816kgs.pdf)
* [Technical Manual](https://opensmarthouse.org/zwavedatabase/139/reference/eco2advanced-zwave-configuration-v2.pdf)
---

View File

@ -30,6 +30,10 @@ The ARZ Z-Wave roller shutters are intended for mounting onto FAKRO roof windows
**Exclude** - This function allow you to remove roller shutter from the network Z-Wave. Follow the procedur removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second. Function removes information only about newtork Z-Wave.
### General Usage Information
## Channels
The following table summarises the channels available for the ARZ 1.1 -:

View File

@ -61,7 +61,6 @@ The following table summarises the channels available for the MH-S220 -:
| Switch | switch_binary | switch_binary | Switch | Switch |
| Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
| Scene Number | scene_number | scene_number | | Number |
| Scene Number | scene_number | scene_number | | Number |
| Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
### Switch
@ -78,11 +77,6 @@ The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the
### Scene Number
Triggers when a scene button is pressed.
The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item.
### Scene Number
Triggers when a scene button is pressed.
The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item.
This channel provides the scene, and the event as a decimal value in the form ```<scene>.<event>```. The scene number is set by the device, and the event is as follows -:

View File

@ -7,6 +7,7 @@ title: MH-S220 - ZWave
# MH-S220 Micro Switch
This describes the Z-Wave device *MH-S220*, manufactured by *[McoHome Technology Co., Ltd](http://www.mcohome.com/)* with the thing type UID of ```mcohome_mhs220_00_000```.
This version of the device is limited to firmware versions below 3.1
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
@ -42,6 +43,10 @@ EXCLUDING the Micro Switch from your network:
Note: If the exclusion is successful, the Micro Switch INDICATION LED will blink slowly. If not, INDICATION LED will be solid on or off depending on switchs state.
### General Usage Information
## Channels
The following table summarises the channels available for the MH-S220 -:

View File

@ -0,0 +1,298 @@
---
layout: documentation
title: ZSE43 - ZWave
---
{% include base.html %}
# ZSE43 Tilt / Shock Sensor
This describes the Z-Wave device *ZSE43*, manufactured by *[Zooz](http://www.getzooz.com/)* with the thing type UID of ```zooz_zse43_00_000```.
The device is in the category of *Battery*, defining Batteries, Energy Storages.
![ZSE43 product image](https://opensmarthouse.org/zwavedatabase/1481/image/)
The ZSE43 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZSE43 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the *Wakeup Information* section below for further information.
## Overview
Battery Powered Tilt / Shock sensor
* Tilt monitoring for garage doors and gates: quick open/close reports you can depend on sent to your Z-Wave system for both vertical and horizontal tilt movement (NOT suitable for swinging gates or doors)
* Shock sensor: monitor window glass and other surfaces for vibration to improve security of your home
### Inclusion Information
1. Put the Z-Wave hub into inclusion/pairing mode (see your hub's manual for instructions since each brand is different)
2. Click the Z-Wave button 3 times quickly (button inside cover by battery)
3. The new device should appear on your hub's device list
### Exclusion Information
1. Bring the Sensor within 3 feet of your Z-Wave hub
2. Put your Z-Wave hub into exclusion mode (see your controller's manual for details, as each brand is different)
3. Click the Z-Wave button 3 times quickly (button inside cover by battery)
4. Your hub should confirm exclusion and the sensor will disappear from the interface
### Wakeup Information
The ZSE43 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Click the Z-Wave button 4 times quickly to wake the sensor up manually. The LED indicator will flash twice to confirm the device is awake. During wake-up, the sensor turns the Z-Wave radio on for one minute to receive communication from the hub. 
### General Usage Information
## Channels
The following table summarises the channels available for the ZSE43 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
| Binary Sensor | sensor_binary | sensor_binary | | Switch |
| Alarm (access) | alarm_access | alarm_access | Door | Switch |
| Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
| Battery Level | battery-level | system.battery_level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered.
The ```sensor_binary``` channel is of type ```sensor_binary``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| ON | Triggered |
| OFF | Untriggered |
### Alarm (access)
Indicates if the access control alarm is triggered.
The ```alarm_access``` channel is of type ```alarm_access``` and supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Alarm (burglar)
Indicates if the burglar alarm is triggered.
The ```alarm_burglar``` channel is of type ```alarm_burglar``` and supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
## Device Configuration
The following table provides a summary of the 9 configuration parameters available in the ZSE43.
Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|-------|-------|-------------|
| 1 | LED indicator for tilt or shock | Turns the LED indicator for tilt or shock sensor status change on or off. |
| 2 | Battery Reporting | Set the threshold for battery reporting. |
| 3 | Battery Reporting - Low | Decide when the sensor should report low battery to the hub. |
| 4 | Shock Sensor Sensitivity | Set the vibration sensor's level of sensitivity. |
| 5 | Tilt Sensor Group 2 Association Commands - On Delay | Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open. |
| 6 | Tilt Sensor Group 2 Association Commands - Off Delay | Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed. |
| 7 | Disable Tilt or Shock Sensor | Disable one of the sensors reports if needed |
| 8 | Tilt Sensor Group 2 Association Commands - Commands | Decide what type of Basic Set commands are sent to devices associated in Group 2. |
| 9 | Shock Sensor Group 3 Association Commands | Decide what type of Basic Set commands are sent to devices associated in Group 3. |
| | Wakeup Interval | Sets the interval at which the device will accept commands from the controller |
| | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
### Parameter 1: LED indicator for tilt or shock
Turns the LED indicator for tilt or shock sensor status change on or off.
Values: 0 LED wont blink when either sensor is triggered; 1 LED blinks only when the shock sensor is triggered; 2 LED blinks only when the tilt sensor is triggered; 3  LED blinks when either sensor is triggered (default).
Values in the range 0 to 3 may be set.
The manufacturer defined default value is ```3```.
This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```.
### Parameter 2: Battery Reporting
Set the threshold for battery reporting.
Values: 1-50 (%). Default: 5This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 1 to 50 may be set.
The manufacturer defined default value is ```5```.
This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```.
### Parameter 3: Battery Reporting - Low
Decide when the sensor should report low battery to the hub.
Values: 10-50 (% battery life). Default: 20This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 10 to 50 may be set.
The manufacturer defined default value is ```20```.
This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```.
### Parameter 4: Shock Sensor Sensitivity
Set the vibration sensor's level of sensitivity.
Values: 0 highest level of sensitivity, will report the recorded vibration immediately (default); 1 medium level of sensitivity, will report only if the vibration is recorded for 1.5 seconds or longer, it will keep reporting vibration for 2 more seconds after the last recorded activity; 2 lowest level of sensitivity, will report only if the vibration is recorded for 2.5 seconds or longer, it will keep reporting vibration for 3 more seconds after the last recorded activity.
Values in the range 0 to 2 may be set.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```.
### Parameter 5: Tilt Sensor Group 2 Association Commands - On Delay
Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.
Values: 0-3600 (seconds). Default: 0 (no delay).This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 3600 may be set.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_5_4``` and is of type ```INTEGER```.
### Parameter 6: Tilt Sensor Group 2 Association Commands - Off Delay
Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.
Values: 0-3600 (seconds). Default: 0 (no delay).This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 3600 may be set.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_6_3``` and is of type ```INTEGER```.
### Parameter 7: Disable Tilt or Shock Sensor
Disable one of the sensors reports if needed
Values: 0 only tilt sensor enabled; 1 only shock sensor enabled; 2 both sensors enabled (default).
Values in the range 0 to 2 may be set.
The manufacturer defined default value is ```2```.
This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```.
### Parameter 8: Tilt Sensor Group 2 Association Commands - Commands
Decide what type of Basic Set commands are sent to devices associated in Group 2.
Values: 0 all Basic Set commands to Group 2 disabled; 1 only Basic Set ON commands to Group 2 enabled; 2 only Basic Set OFF commands to Group 2 enabled; 3 both Basic Set commands (for on and off) to Group 2 enabled (default).This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 3 may be set.
The manufacturer defined default value is ```3```.
This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```.
### Parameter 9: Shock Sensor Group 3 Association Commands
Decide what type of Basic Set commands are sent to devices associated in Group 3.
Values: 0 all Basic Set commands to Group 3 disabled; 1 only Basic Set ON commands to Group 3 enabled; 2 only Basic Set OFF commands to Group 3 enabled; 3 both Basic Set commands (for on and off) to Group 3 enabled (default).This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 0 may be set.
The manufacturer defined default value is ```3```.
This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```.
### Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZSE43 supports 3 association groups.
### Group 1: Lifeline to hub
Association group 1 supports 1 node.
### Group 2: Basic set for open / close (tilt sensor)
Association group 2 supports 5 nodes.
### Group 3: Basic set for vibration / no vibration (shock sensor)
Association group 3 supports 4 nodes.
## Technical Information
### Endpoints
#### Endpoint 0
| Command Class | Comment |
|---------------|---------|
| COMMAND_CLASS_NO_OPERATION_V1| |
| COMMAND_CLASS_SENSOR_BINARY_V2| |
| COMMAND_CLASS_TRANSPORT_SERVICE_V1| |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |
| COMMAND_CLASS_SUPERVISION_V1| |
| COMMAND_CLASS_CONFIGURATION_V1| |
| COMMAND_CLASS_ALARM_V8| |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| |
| COMMAND_CLASS_POWERLEVEL_V1| |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| |
| COMMAND_CLASS_BATTERY_V1| |
| COMMAND_CLASS_WAKE_UP_V2| |
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_VERSION_V2| |
| COMMAND_CLASS_INDICATOR_V3| |
| COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |
| COMMAND_CLASS_SECURITY_2_V1| |
### Documentation Links
* [Zooz SE43 Manual](https://opensmarthouse.org/zwavedatabase/1481/reference/zooz-700-series-tilt-shock-xs-sensor-zse43-manual-online.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1481).

View File

@ -0,0 +1,48 @@
<?xml version="1.0" encoding="UTF-8"?>
<thing:thing-descriptions bindingId="zigbee"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0 https://openhab.org/schemas/thing-description-1.0.0.xsd">
<thing-type id="xiaomi_lumiremotemini" listed="false">
<label>AQARA WXKG11LM</label>
<description>Smart Wireless Switch</description>
<category>WallSwitch</category>
<channels>
<channel id="center" typeId="system.button">
<label>Center</label>
<properties>
<property name="zigbee_endpoint">1</property>
<property name="zigbee_shortpress_cluster_id">0x0012</property>
<property name="zigbee_shortpress_attribute_id">85</property>
<property name="zigbee_shortpress_attribute_value">1</property>
<property name="zigbee_longpress_cluster_id">0x0012</property>
<property name="zigbee_longpress_attribute_id">85</property>
<property name="zigbee_longpress_attribute_value">0</property>
<property name="zigbee_doublepress_cluster_id">0x0012</property>
<property name="zigbee_doublepress_attribute_id">85</property>
<property name="zigbee_doublepress_attribute_value">2</property>
</properties>
</channel>
<channel id="range-check" typeId="system.button">
<label>Range Check</label>
<properties>
<property name="zigbee_endpoint">1</property>
<property name="zigbee_shortpress_cluster_id">0x00</property>
<property name="zigbee_shortpress_attribute_id">5</property>
<property name="zigbee_shortpress_attribute_value">lumi.remote.b1acn01</property>
</properties>
</channel>
</channels>
<representation-property>zigbee_macaddress</representation-property>
<config-description>
<parameter name="zigbee_macaddress" type="text" readOnly="true" required="true">
<label>MAC Address</label>
</parameter>
</config-description>
</thing-type>
</thing:thing-descriptions>

View File

@ -14,16 +14,16 @@ Z-Wave Garage Door Sensor<br /> <h1>Overview</h1><p>Sensor which transmits when
<!-- CHANNEL DEFINITIONS -->
<channels>
<channel id="alarm_tamper" typeId="alarm_tamper">
<label>Tamper Alarm</label>
<channel id="sensor_door" typeId="sensor_door">
<label>Binary Sensor</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM</property>
<property name="binding:*:OpenClosedType">COMMAND_CLASS_SENSOR_BINARY</property>
</properties>
</channel>
<channel id="sensor_door" typeId="sensor_door">
<label>Door State [Deprecated]</label>
<channel id="alarm_tamper" typeId="alarm_tamper">
<label>Tamper Alarm Cover Off</label>
<properties>
<property name="binding:*:OpenClosedType">COMMAND_CLASS_ALARM</property>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM</property>
</properties>
</channel>
<channel id="battery-level" typeId="system.battery-level">
@ -40,7 +40,6 @@ Z-Wave Garage Door Sensor<br /> <h1>Overview</h1><p>Sensor which transmits when
<property name="manufacturerId">014A</property>
<property name="manufacturerRef">0001:0003</property>
<property name="dbReference">139</property>
<property name="commandClass:COMMAND_CLASS_ALARM">getSupported=false</property>
<property name="defaultAssociations">1</property>
</properties>

View File

@ -8,7 +8,7 @@
<thing-type id="fakro_arz2_01_001" listed="false">
<label>ARZ 1.1 Roller Shutter Module</label>
<description><![CDATA[
Roller Shutter Module<br /> <h1>Overview</h1><p>The ARZ Z-Wave roller shutters are intended for mounting onto FAKRO roof windows.</p> <br /> <h2>Inclusion Information</h2><p><strong>Autoinclusion</strong> - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power roller shutter (OFF-ON-OFF-ON-OFF-ON) causes the introduction of roller shutter to Autoinclusion mode. Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an awning to any Z-Wave controller running in the Include procedure.</p> <p><strong>Include</strong> - This function allow you to add roller shutter to the network Z-Wave. Follow the procedur adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second.</p> <br /> <h2>Exclusion Information</h2><p><strong>Exclude</strong> - This function allow you to remove roller shutter from the network Z-Wave. Follow the procedur removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second. Function removes information only about newtork Z-Wave.</p>
Roller Shutter Module<br /> <h1>Overview</h1><p>The ARZ Z-Wave roller shutters are intended for mounting onto FAKRO roof windows.</p> <br /> <h2>Inclusion Information</h2><p><strong>Autoinclusion</strong> - This feature allow you to add hard to reach devices to Z-Wave network. 3-times ON and OFF the power roller shutter (OFF-ON-OFF-ON-OFF-ON) causes the introduction of roller shutter to Autoinclusion mode. Please note that the procedure has been started the time between on and off can not exceed 20s. Autoinclusion mode is activated for a maximum of 10 minutes. During this time, we can add an awning to any Z-Wave controller running in the Include procedure.</p> <p><strong>Include</strong> - This function allow you to add roller shutter to the network Z-Wave. Follow the procedur adding device to the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second.</p> <br /> <h2>Exclusion Information</h2><p><strong>Exclude</strong> - This function allow you to remove roller shutter from the network Z-Wave. Follow the procedur removing device from the network Z-Wave according to user manual supplied with the product. Then, press the programming button P on the roller shutter for 1 second. Function removes information only about newtork Z-Wave.</p> <br /> <h2>Wakeup Information</h2><p><br /></p>
]]></description>
<category>Blinds</category>

View File

@ -188,7 +188,7 @@ RGBW CONTROLLER 2<br /> <h1>Overview</h1><p>FIBARO RGBW Controller 2 uses PWM ou
<property name="vendor">Fibargroup</property>
<property name="modelId">FGRGBW-442</property>
<property name="manufacturerId">010F</property>
<property name="manufacturerRef">0902:1000,0902:2000,0902:3000,0902:4000</property>
<property name="manufacturerRef">0902:1000,0902:2000,0902:3000,0902:4000,0902:6000</property>
<property name="dbReference">1127</property>
<property name="defaultAssociations">1</property>
</properties>

View File

@ -8,7 +8,7 @@
<thing-type id="fibaro_fgrgbw_00_000" listed="false">
<label>FGRGBW RGBW Controller</label>
<description><![CDATA[
RGBW Controller<br /> <h1>Overview</h1><p>Fibaro RGBW Controller is a universal, Z-Wave compatible RGB / RGBW controller. Fibaro RGBW Controller uses PWM output signal, which enables it to control LED, RGB, RGBW strips, halogen lights and fans. Controlled devices may be powered by 12 or 24 VDC. In addition the device supports up to four, 0V - 10V analog sensors, such as temperature sensors, humidity sensors, wind sensors, air quality sensors, light sensors etc. All IN and OUT terminals may be user configured for LED control or 0V-10V signal readouts. </p> <br /> <h2>Inclusion Information</h2><p>Triple click the B-button or any switch connected to I1-I4 inputs</p> <br /> <h2>Exclusion Information</h2><p>Triple click the B-button or any switch connected to I1-I4 inputs</p>
RGBW Controller<br /> <h1>Overview</h1><p>Fibaro RGBW Controller is a universal, Z-Wave compatible RGB / RGBW controller. Fibaro RGBW Controller uses PWM output signal, which enables it to control LED, RGB, RGBW strips, halogen lights and fans. Controlled devices may be powered by 12 or 24 VDC. In addition the device supports up to four, 0V - 10V analog sensors, such as temperature sensors, humidity sensors, wind sensors, air quality sensors, light sensors etc. All IN and OUT terminals may be user configured for LED control or 0V-10V signal readouts. </p> <br /> <h2>Inclusion Information</h2><p>Triple click the B-button or any switch connected to I1-I4 inputs</p> <br /> <h2>Exclusion Information</h2><p>Triple click the B-button or any switch connected to I1-I4 inputs</p> <br /> <h2>Wakeup Information</h2><p><br /></p>
]]></description>
<category>WallSwitch</category>

View File

@ -27,12 +27,6 @@ Micro Switch<br /> <h1>Overview</h1><p>MCOHome Micro Switch MH-S220-EU is a Z-Wa
<property name="binding:Command:OnOffType">COMMAND_CLASS_SWITCH_MULTILEVEL</property>
</properties>
</channel>
<channel id="scene_number" typeId="scene_number">
<label>Scene Number</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_SCENE_ACTIVATION</property>
</properties>
</channel>
<channel id="scene_number" typeId="scene_number">
<label>Scene Number</label>
<properties>

View File

@ -8,7 +8,7 @@
<thing-type id="mcohome_mhs220_00_000" listed="false">
<label>MH-S220 Micro Switch</label>
<description><![CDATA[
Micro Switch<br /> <h1>Overview</h1><p>MCOHome Micro Switch MH-S220-EU is a Z-Wave enabled module that can be set in existing in-wall switches. It supports basic command class, and also can act as a repeater in Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.</p> <ul><li>Power supply: 220V 50Hz</li> <li>Max output: 10A (Zero-crossing switch)</li> <li>Dimension44 *38 *17mm (L *W *H)</li> <li>Load Type: Incandescent</li> </ul> <br /> <h2>Inclusion Information</h2><p>INCLUDING the Micro Switch into your network:</p> <ol><li>Set the controller into INCLUSION mode. Follow the instructions provided by the controller manufacturer.</li> <li>Press the ON/OFF/PROGRAM button on the Micro Switch.</li> </ol><p>Note: If the inclusion is successful, the Micro Switch INDICATION LED will be solid on or off depending on switchs state. If not, INDICATION LED will blink slowly.</p> <br /> <h2>Exclusion Information</h2><p>EXCLUDING the Micro Switch from your network:</p> <ol><li>Set the controller into EXCLUSION mode. Follow the instructions provided by the controller manufacturer.</li> <li>Press the ON/OFF/PROGRAM button on the Micro Switch.</li> </ol><p>Note: If the exclusion is successful, the Micro Switch INDICATION LED will blink slowly. If not, INDICATION LED will be solid on or off depending on switchs state.</p>
Micro Switch<br /> <h1>Overview</h1><p>MCOHome Micro Switch MH-S220-EU is a Z-Wave enabled module that can be set in existing in-wall switches. It supports basic command class, and also can act as a repeater in Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.</p> <ul><li>Power supply: 220V 50Hz</li> <li>Max output: 10A (Zero-crossing switch)</li> <li>Dimension44 *38 *17mm (L *W *H)</li> <li>Load Type: Incandescent</li> </ul> <br /> <h2>Inclusion Information</h2><p>INCLUDING the Micro Switch into your network:</p> <ol><li>Set the controller into INCLUSION mode. Follow the instructions provided by the controller manufacturer.</li> <li>Press the ON/OFF/PROGRAM button on the Micro Switch.</li> </ol><p>Note: If the inclusion is successful, the Micro Switch INDICATION LED will be solid on or off depending on switchs state. If not, INDICATION LED will blink slowly.</p> <br /> <h2>Exclusion Information</h2><p>EXCLUDING the Micro Switch from your network:</p> <ol><li>Set the controller into EXCLUSION mode. Follow the instructions provided by the controller manufacturer.</li> <li>Press the ON/OFF/PROGRAM button on the Micro Switch.</li> </ol><p>Note: If the exclusion is successful, the Micro Switch INDICATION LED will blink slowly. If not, INDICATION LED will be solid on or off depending on switchs state.</p> <br /> <h2>Wakeup Information</h2><p><br /></p>
]]></description>
<category>WallSwitch</category>
@ -40,6 +40,7 @@ Micro Switch<br /> <h1>Overview</h1><p>MCOHome Micro Switch MH-S220-EU is a Z-Wa
<property name="modelId">MH-S220</property>
<property name="manufacturerId">015F</property>
<property name="manufacturerRef">2201:1252</property>
<property name="versionMax">3.1</property>
<property name="dbReference">1153</property>
<property name="defaultAssociations">3</property>
</properties>

View File

@ -0,0 +1,180 @@
<?xml version="1.0" encoding="UTF-8"?>
<thing:thing-descriptions bindingId="zwave"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0
https://openhab.org/schemas/thing-description/v1.0.0">
<thing-type id="zooz_zse43_00_000" listed="false">
<label>ZSE43 Tilt / Shock Sensor</label>
<description><![CDATA[
Tilt / Shock Sensor<br /> <h1>Overview</h1><p>Battery Powered Tilt / Shock sensor</p><ul><li>Tilt monitoring for garage doors and gates: quick open/close reports you can depend on sent to your Z-Wave system for both vertical and horizontal tilt movement (NOT suitable for swinging gates or doors)</li><li>Shock sensor: monitor window glass and other surfaces for vibration to improve security of your home</li></ul> <br /> <h2>Inclusion Information</h2><ol><li>Put the Z-Wave hub into inclusion/pairing mode (see your hub's manual for instructions since each brand is different)</li><li>Click the Z-Wave button 3 times quickly (button inside cover by battery)</li><li>The new device should appear on your hub's device list</li></ol> <br /> <h2>Exclusion Information</h2><ol><li>Bring the Sensor within 3 feet of your Z-Wave hub </li><li>Put your Z-Wave hub into exclusion mode (see your controller's manual for details, as each brand is different)</li><li>Click the Z-Wave button 3 times quickly (button inside cover by battery)</li><li>Your hub should confirm exclusion and the sensor will disappear from the interface</li></ol> <br /> <h2>Wakeup Information</h2><p>Click the Z-Wave button 4 times quickly to wake the sensor up manually. The LED indicator will flash twice to confirm the device is awake. During wake-up, the sensor turns the Z-Wave radio on for one minute to receive communication from the hub. </p>
]]></description>
<category>Battery</category>
<!-- CHANNEL DEFINITIONS -->
<channels>
<channel id="sensor_binary" typeId="sensor_binary">
<label>Binary Sensor</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_SENSOR_BINARY</property>
</properties>
</channel>
<channel id="alarm_access" typeId="alarm_access">
<label>Alarm (access)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=ACCESS_CONTROL</property>
</properties>
</channel>
<channel id="alarm_burglar" typeId="alarm_burglar">
<label>Alarm (burglar)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=BURGLAR</property>
</properties>
</channel>
<channel id="battery-level" typeId="system.battery-level">
<properties>
<property name="binding:*:PercentType">COMMAND_CLASS_BATTERY</property>
</properties>
</channel>
</channels>
<!-- DEVICE PROPERTY DEFINITIONS -->
<properties>
<property name="vendor">Zooz</property>
<property name="modelId">ZSE43</property>
<property name="manufacturerId">027A</property>
<property name="manufacturerRef">7000:E003</property>
<property name="dbReference">1481</property>
<property name="defaultAssociations">1</property>
</properties>
<!-- CONFIGURATION DESCRIPTIONS -->
<config-description>
<!-- GROUP DEFINITIONS -->
<parameter-group name="configuration">
<context>setup</context>
<label>Configuration Parameters</label>
</parameter-group>
<parameter-group name="association">
<context>link</context>
<label>Association Groups</label>
</parameter-group>
<!-- PARAMETER DEFINITIONS -->
<parameter name="config_1_1" type="integer" groupName="configuration">
<label>1: LED indicator for tilt or shock</label>
<description><![CDATA[
Turns the LED indicator for tilt or shock sensor status change on or off.<br /> <h1>Overview</h1><p>Values: 0 LED wont blink when either sensor is triggered; 1 LED blinks only when the shock sensor is triggered; 2 LED blinks only when the tilt sensor is triggered; 3  LED blinks when either sensor is triggered (default).</p>
]]></description>
<default>3</default>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_2_1" type="integer" groupName="configuration">
<label>2: Battery Reporting</label>
<description><![CDATA[
Set the threshold for battery reporting.<br /> <h1>Overview</h1><p>Values: 1-50 (%). Default: 5<br /></p>
]]></description>
<default>5</default>
<advanced>true</advanced>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_3_1" type="integer" groupName="configuration">
<label>3: Battery Reporting - Low</label>
<description><![CDATA[
Decide when the sensor should report low battery to the hub.<br /> <h1>Overview</h1><p>Values: 10-50 (% battery life). Default: 20<br /></p>
]]></description>
<default>20</default>
<advanced>true</advanced>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_4_1" type="integer" groupName="configuration">
<label>4: Shock Sensor Sensitivity</label>
<description><![CDATA[
Set the vibration sensor's level of sensitivity.<br /> <h1>Overview</h1><p>Values: 0 highest level of sensitivity, will report the recorded vibration immediately (default); 1 medium level of sensitivity, will report only if the vibration is recorded for 1.5 seconds or longer, it will keep reporting vibration for 2 more seconds after the last recorded activity; 2 lowest level of sensitivity, will report only if the vibration is recorded for 2.5 seconds or longer, it will keep reporting vibration for 3 more seconds after the last recorded activity.<br /></p>
]]></description>
<default>0</default>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_5_4" type="integer" groupName="configuration">
<label>5: Tilt Sensor Group 2 Association Commands - On Delay</label>
<description><![CDATA[
Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.<br /> <h1>Overview</h1><p>Values: 0-3600 (seconds). Default: 0 (no delay).<br /></p>
]]></description>
<default>0</default>
<advanced>true</advanced>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_6_3" type="integer" groupName="configuration">
<label>6: Tilt Sensor Group 2 Association Commands - Off Delay</label>
<description><![CDATA[
Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.<br /> <h1>Overview</h1><p>Values: 0-3600 (seconds). Default: 0 (no delay).<br /></p>
]]></description>
<default>0</default>
<advanced>true</advanced>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_7_1" type="integer" groupName="configuration">
<label>7: Disable Tilt or Shock Sensor</label>
<description><![CDATA[
Disable one of the sensors reports if needed<br /> <h1>Overview</h1><p>Values: 0 only tilt sensor enabled; 1 only shock sensor enabled; 2 both sensors enabled (default).<br /></p>
]]></description>
<default>2</default>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_8_1" type="integer" groupName="configuration">
<label>8: Tilt Sensor Group 2 Association Commands - Commands</label>
<description><![CDATA[
Decide what type of Basic Set commands are sent to devices associated in Group 2.<br /> <h1>Overview</h1><p>Values: 0 all Basic Set commands to Group 2 disabled; 1 only Basic Set ON commands to Group 2 enabled; 2 only Basic Set OFF commands to Group 2 enabled; 3 both Basic Set commands (for on and off) to Group 2 enabled (default).<br /></p>
]]></description>
<default>3</default>
<advanced>true</advanced>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_9_1" type="integer" groupName="configuration">
<label>9: Shock Sensor Group 3 Association Commands</label>
<description><![CDATA[
Decide what type of Basic Set commands are sent to devices associated in Group 3.<br /> <h1>Overview</h1><p>Values: 0 all Basic Set commands to Group 3 disabled; 1 only Basic Set ON commands to Group 3 enabled; 2 only Basic Set OFF commands to Group 3 enabled; 3 both Basic Set commands (for on and off) to Group 3 enabled (default).<br /></p>
]]></description>
<default>3</default>
<advanced>true</advanced>
<limitToOptions>false</limitToOptions>
</parameter>
<!-- ASSOCIATION DEFINITIONS -->
<parameter name="group_1" type="text" groupName="association" multiple="true">
<label>1: Lifeline to hub</label>
<multipleLimit>1</multipleLimit>
</parameter>
<parameter name="group_2" type="text" groupName="association" multiple="true">
<label>2: Basic set for open / close (tilt sensor)</label>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_3" type="text" groupName="association" multiple="true">
<label>3: Basic set for vibration / no vibration (shock sensor)</label>
<multipleLimit>4</multipleLimit>
</parameter>
<!-- STATIC DEFINITIONS -->
<parameter name="node_id" type="integer" min="1" max="232" readOnly="true" required="true">
<label>Node ID</label>
<advanced>true</advanced>
</parameter>
</config-description>
</thing-type>
</thing:thing-descriptions>