Optimize profile example section layout (#1543)
* Optimize profile example section layout Signed-off-by: Patrick Fink <mail@pfink.de> * Fix copy&paste error Signed-off-by: Patrick Fink <mail@pfink.de> * Use good coding practice für multi channel linkage Signed-off-by: Patrick Fink <mail@pfink.de>pull/1545/head
parent
c4b6ad7196
commit
9d7d289bdc
|
@ -617,7 +617,10 @@ Commands and Updates from and to these Items will be combined, and can be used i
|
|||
Example:
|
||||
|
||||
```java
|
||||
Switch Office_PC {channel="lgwebos:WebOSTV:01dd3ac4-62f4-7505-208b-12345679", channel="network:servicedevice:6d5de4e65d"}
|
||||
Switch Office_PC {
|
||||
channel="lgwebos:WebOSTV:01dd3ac4-62f4-7505-208b-12345679",
|
||||
channel="network:servicedevice:6d5de4e65d"
|
||||
}
|
||||
```
|
||||
|
||||
The first example shows a symbiosis of the LG webOS Binding and the Wake-on-LAN Binding to interact with a TV.
|
||||
|
@ -710,7 +713,7 @@ You can find the documentation of these Profiles within the [Add-On documentatio
|
|||
| `rawrocker-to-play-pause`, `rawrocker-to-next-previous` and `rawrocker-to-rewind-fastforward` | Trigger | Player | These Profiles can only be used on Channels of the type `system.rawrocker` and Player Items. They will convert a press on the first rocker button to an `PLAY` / `NEXT` / `FASTFORWARD` command while the second one will be converted to an `PAUSE` / `PREVIOUS` / `REWIND` command. |
|
||||
| `rawrocker-to-stop-move` and `rawrocker-to-up-down` | Trigger | Rollershutter | These Profiles can only be used on Channels of the type `system.rawrocker` and Rollershutter Items. They will convert a press on the first rocker button to an `MOVE` / `UP` command while the second one will be converted to an `STOP` / `DOWN` command. |
|
||||
|
||||
##### Example 1
|
||||
##### Basic Example
|
||||
|
||||
You have an Item called `Bedroom_Light` that is connected to a Hue lamp
|
||||
|
||||
|
@ -734,29 +737,31 @@ end
|
|||
Instead of using this Rule, you can also use the `rawbutton-toggle-switch` Profile in combination with [Multi-Channel Linking](#multi-binding-channel-linkage):
|
||||
|
||||
```java
|
||||
Color Bedroom_Light { channel="hue:0210:1:bulb1:color", channel="serialbutton:button:mybutton:button" [profile="system:rawbutton-toggle-switch"] }
|
||||
Color Bedroom_Light {
|
||||
channel="hue:0210:1:bulb1:color",
|
||||
channel="serialbutton:button:mybutton:button" [profile="system:rawbutton-toggle-switch"]
|
||||
}
|
||||
```
|
||||
|
||||
This will make your Rule obsolete.
|
||||
So with Profiles, you can significantly reduce the amount of Rules you need for your Smart Home which helps you to keep your configuration short and clear.
|
||||
|
||||
##### Example 2
|
||||
##### Advanced Examples
|
||||
|
||||
```java
|
||||
/** Hysteresis Profile **/
|
||||
Number:Temperature Outdoor_Temperature { channel="openweathermap:weather-and-forecast:api:local:current#temperature" }
|
||||
// Triggers a temperature high alarm (Switch = ON) as of 30 °c and stays ON until temperature drops below 29 °C
|
||||
Switch Outdoor_Temperature_High_Alert { channel="openweathermap:weather-and-forecast:api:local:current#temperature" [profile="system:hysteresis", lower="29 °C", upper="30 °C"] }
|
||||
// Temperture low alert below 0 °C
|
||||
Switch Outdoor_Temperature_Low_Alert { channel="openweathermap:weather-and-forecast:api:local:current#temperature" [profile="system:hysteresis", lower="0 °C", inverted=true] }
|
||||
|
||||
// Indicates a battery low alarm if battery level drops below 15
|
||||
/** Battery Level Profile **/
|
||||
Number Battery_Level { channel="serialbutton:button:mybutton:battery-level" }
|
||||
// Indicates a battery low alarm if battery level drops below 15
|
||||
Switch Low_Battery { channel="serialbutton:button:mybutton:battery-level" [profile="system:hysteresis", lower=15, inverted=true] }
|
||||
```
|
||||
|
||||
##### Example 5
|
||||
|
||||
```java
|
||||
/** Range Profile **/
|
||||
Number:Dimensionless Outdoor_Humidity { channel="openweathermap:weather-and-forecast:api:local:current#humidity" }
|
||||
// Triggers a humidity low / high alarm (Switch = ON) if humidity drops below 40 % or exceeds 60 %
|
||||
Switch Outdoor_Humidity_Alert { channel="openweathermap:weather-and-forecast:api:local:current#humidity" [profile="system:range", lower="40 %", upper="60 %", inverted=true] }
|
||||
|
|