@ -58,7 +58,7 @@ Useful tools
|
|
|
|
|
|
|
|
|
|
## Supported Things
|
|
|
|
|
|
|
|
|
|
This binding support 6 different things types
|
|
|
|
|
This binding supports 4 different things types
|
|
|
|
|
|
|
|
|
|
| Thing | Type | Description |
|
|
|
|
|
| -------- | ------ | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
|
|
|
@ -125,7 +125,7 @@ Advanced parameters
|
|
|
|
|
| `reconnectAfterMillis` | | integer | `0` | The connection is kept open at least the time specified here. Value of zero means that connection is disconnected after every MODBUS transaction. In milliseconds. |
|
|
|
|
|
| `connectTimeoutMillis` | | integer | `10000` | The maximum time that is waited when establishing the connection. Value of zero means that system/OS default is respected. In milliseconds. |
|
|
|
|
|
|
|
|
|
|
**Note:** Advanced parameters must be equal to all `tcp` things sharing the same `host` and `port`.
|
|
|
|
|
**Note:** Advanced parameters must be equal for all `tcp` things sharing the same `host` and `port`.
|
|
|
|
|
|
|
|
|
|
The advanced parameters have conservative defaults, meaning that they should work for most users.
|
|
|
|
|
In some cases when extreme performance is required (e.g. poll period below 10 ms), one might want to decrease the delay parameters, especially `timeBetweenTransactionsMillis`. Similarly, with some slower devices on might need to increase the values.
|
|
|
|
@ -158,7 +158,7 @@ Advanced parameters
|
|
|
|
|
| `connectMaxTries` | | integer | `1` | How many times we try to establish the connection. Should be at least 1. |
|
|
|
|
|
| `connectTimeoutMillis` | | integer | `10000` | The maximum time that is waited when establishing the connection. Value of zero means thatsystem/OS default is respected. In milliseconds. |
|
|
|
|
|
|
|
|
|
|
With the exception of `id` parameters should be equal to all `serial` things sharing the same `port`.
|
|
|
|
|
With the exception of `id` parameters should be equal for all `serial` things sharing the same `port`.
|
|
|
|
|
|
|
|
|
|
These parameters have conservative defaults, meaning that they should work for most users.
|
|
|
|
|
In some cases when extreme performance is required (e.g. poll period below 10ms), one might want to decrease the delay parameters, especially `timeBetweenTransactionsMillis`.
|
|
|
|
@ -243,13 +243,14 @@ For example, in the following example, item `Temperature_Modbus_Livingroom` is b
|
|
|
|
|
Number Temperature_Modbus_Livingroom "Temperature Living room [%.1f °C]" <temperature> { channel="modbus:data:siemensplc:holding:livingroom_temperature:number" }
|
|
|
|
|
```
|
|
|
|
|
|
|
|
|
|
Make sure you bind item to a channel that is compatible, or use transformations to make it compatible. See [Transformations](#transformations) section for more information on transformation.
|
|
|
|
|
Make sure you bind item to a channel that is compatible, or use transformations to make it compatible.
|
|
|
|
|
See [Transformations](#transformations) section for more information on transformation.
|
|
|
|
|
|
|
|
|
|
### `autoupdate` parameter with items
|
|
|
|
|
|
|
|
|
|
Please note that Modbus protocol is polling, and commands in openHAB might take some time to propagate. This might produce some transient effects with item values when parameters are changed.
|
|
|
|
|
|
|
|
|
|
By default, openHAB has `autoupdate` enabled. This means that item _state_ is updated according to received commands. In some situations this might have unexpected side effects with polling bindings such as Modbus - see example below.
|
|
|
|
|
By default, openHAB has `autoupdate` enabled.
|
|
|
|
|
This means that item _state_ is updated according to received commands.
|
|
|
|
|
In some situations this might have unexpected side effects with polling bindings such as Modbus - see example below.
|
|
|
|
|
|
|
|
|
|
Typically, you see something like this
|
|
|
|
|
|
|
|
|
@ -275,7 +276,8 @@ Let's go through it step by step
|
|
|
|
|
4 [vent.ItemStateChangedEvent] - Kitchen_Bar_Table_Light changed from OFF to ON
|
|
|
|
|
```
|
|
|
|
|
|
|
|
|
|
To prevent this "state fluctuation" (`OFF` -> `ON` -> `OFF` -> `ON`), some people prefer like to disable `autoupdate` with polling bindings. With `autoupdate` disabled, one would get
|
|
|
|
|
To prevent this "state fluctuation" (`OFF` -> `ON` -> `OFF` -> `ON`), some people prefer to disable `autoupdate` on Items used with polling bindings.
|
|
|
|
|
With `autoupdate` disabled, one would get
|
|
|
|
|
|
|
|
|
|
```java
|
|
|
|
|
// openHAB UI switch changed command is sent
|
|
|
|
@ -289,9 +291,8 @@ To prevent this "state fluctuation" (`OFF` -> `ON` -> `OFF` -> `ON`), some peopl
|
|
|
|
|
Item state has no "fluctuation", it updates from `OFF` to `ON`.
|
|
|
|
|
|
|
|
|
|
To summarize (credits to [rossko57's community post](https://community.openhab.org/t/rule-to-postupdate-an-item-works-but-item-falls-back-after-some-seconds/19986/2?u=ssalonen)):
|
|
|
|
|
|
|
|
|
|
* `autoupdate=false`: monitor the _actual_ state of device
|
|
|
|
|
* `autoupdate=true`: allows more faster display of the _expected_ state in a sitemap
|
|
|
|
|
* `autoupdate="false"`: monitor the _actual_ state of device
|
|
|
|
|
* `autoupdate="true"`: (or defaulted) allows faster display of the _expected_ state in a sitemap
|
|
|
|
|
|
|
|
|
|
You can disable `autoupdate` as follows:
|
|
|
|
|
|
|
|
|
@ -317,14 +318,17 @@ Main documentation on `autoupdate` in [Items section of openHAB docs](https://ww
|
|
|
|
|
>
|
|
|
|
|
> This translates into [entity] addresses between 0 and 9,998 in data frames.
|
|
|
|
|
|
|
|
|
|
Note that entity begins counting at 1, data frame address at 0.
|
|
|
|
|
|
|
|
|
|
The openHAB modbus binding uses data frame entity addresses when referring to modbus entities.
|
|
|
|
|
That is, the entity address configured in modbus binding is passed to modbus protocol frame as-is.
|
|
|
|
|
For example, Modbus `poller` thing with `start=3`, `length=2` and `type=holding` will read modbus entities with the following numbers 40004 and 40005.
|
|
|
|
|
The manufacturer of any modbus device may choose to use either notation, you may have to infer which, or use trial and error.
|
|
|
|
|
|
|
|
|
|
### Value Types On Read And Write
|
|
|
|
|
|
|
|
|
|
This section explains the detailed descriptions of different value types on read and write.
|
|
|
|
|
Note that value types less than 16 bits are not supported on write (see [poller thing](#poller-thing) documentation for details).
|
|
|
|
|
Note that value types less than 16 bits are not supported on write to holding registers (see [poller thing](#poller-thing) documentation for details).
|
|
|
|
|
|
|
|
|
|
See [Full examples](#full-examples) section for practical examples.
|
|
|
|
|
|
|
|
|
@ -384,10 +388,9 @@ See [Full examples](#full-examples) section for practical examples.
|
|
|
|
|
|
|
|
|
|
The MODBUS specification defines each 16bit word to be encoded as Big Endian,
|
|
|
|
|
but there is no specification on the order of those words within 32bit or larger data types.
|
|
|
|
|
The net result is that when you have a master and slave that operate with the same
|
|
|
|
|
Endian mode things work fine, but add a device with a different Endian mode and it is
|
|
|
|
|
very hard to correct. To resolve this the binding supports a second set of valuetypes
|
|
|
|
|
that have the words swapped.
|
|
|
|
|
The net result is that when you have a master and slave that operate with the same Endian mode things work fine,
|
|
|
|
|
but add a device with a different Endian mode and it is very hard to correct.
|
|
|
|
|
To resolve this the binding supports a second set of valuetypes that have the words swapped.
|
|
|
|
|
|
|
|
|
|
If you get strange values using the `int32`, `uint32`, `float32`, `int64`, or `uint64` valuetypes then just try the `int32_swap`, `uint32_swap`, `float32_swap`, `int64_swap`, or `uint64_swap` valuetype, depending upon what your data type is.
|
|
|
|
|
|
|
|
|
@ -435,12 +438,16 @@ Data received is stored in list of bits (discrete inputs and coils), or in list
|
|
|
|
|
1. Extract a single number from the polled data, using specified location `readStart` and number "value type" `readValueType`.
|
|
|
|
|
As an example, we can tell the binding to extract 32-bit float (`readValueType="float32"`) from register index `readStart="105"`.
|
|
|
|
|
1. Number is converted to string (e.g. `"3.14"`) and passed as input to the transformation.
|
|
|
|
|
Note that in case `readTransform="default"`, a default transformation provided by the binding is used. See [Transformations](#transformations) section for more details.
|
|
|
|
|
1. For each [data channel](#channels), we try to convert the transformation output of previous step to a State type (e.g. `ON`/`OFF`, or `DecimalType`) accepted by the channel. If all the conversions fail (e.g. trying to convert `ON` to a number), the data channel is not updated.
|
|
|
|
|
Note that in case `readTransform="default"`, a default transformation provided by the binding is used.
|
|
|
|
|
See [Transformations](#transformations) section for more details.
|
|
|
|
|
1. For each [data channel](#channels), we try to convert the transformation output of previous step to a State type (e.g. `ON`/`OFF`, or `DecimalType`) accepted by the channel.
|
|
|
|
|
If all the conversions fail (e.g. trying to convert `ON` to a number), the data channel is not updated.
|
|
|
|
|
|
|
|
|
|
In case of read errors, all data channels are left unchanged, and `lastReadError` channel is updated with current time. Examples of errors include connection errors, IO errors on read, and explicit exception responses from the slave.
|
|
|
|
|
In case of read errors, all data channels are left unchanged, and `lastReadError` channel is updated with current time.
|
|
|
|
|
Examples of errors include connection errors, IO errors on read, and explicit exception responses from the slave.
|
|
|
|
|
|
|
|
|
|
Note: there is a performance optimization that channel state is only updated when enough time has passed since last update, or when the state differs from previous update. See `updateUnchangedValuesEveryMillis` parameter in `data` thing.
|
|
|
|
|
Note: there is a performance optimization that channel state is only updated when enough time has passed since last update, or when the state differs from previous update.
|
|
|
|
|
See `updateUnchangedValuesEveryMillis` parameter in `data` thing.
|
|
|
|
|
|
|
|
|
|
### Write Steps
|
|
|
|
|
|
|
|
|
@ -451,20 +458,26 @@ Commands passed to openHAB items that are bound to a [data channel](#channels) a
|
|
|
|
|
1. Command is sent to openHAB item, that is bound to a [data channel](#channels).
|
|
|
|
|
Command must be such that it is accepted by the item in the first place
|
|
|
|
|
1. Command is converted to string (e.g. `"3.14"`) and passed to the transformation.
|
|
|
|
|
Note that in case `readTransform="default"`, a default transformation provided by the binding is used. See [Transformations](#transformations) section for more details.
|
|
|
|
|
3. We try to convert transformation output to number (`DecimalType`), `OPEN`/`CLOSED` (`OpenClosedType`), and `ON`/`OFF` (`OnOffType`); in this order. First successful conversion is stored.
|
|
|
|
|
For example, `"3.14"` would convert to number (`DecimalType`), while `"CLOSED"` would convert to `CLOSED` (of `OpenClosedType`).'
|
|
|
|
|
Note that in case `readTransform="default"`, a default transformation provided by the binding is used.
|
|
|
|
|
See [Transformations](#transformations) section for more details.
|
|
|
|
|
3. We try to convert transformation output to number (`DecimalType`), `OPEN`/`CLOSED` (`OpenClosedType`), and `ON`/`OFF` (`OnOffType`); in this order.
|
|
|
|
|
First successful conversion is stored.
|
|
|
|
|
For example, `"3.14"` would convert to number (`DecimalType`), while `"CLOSED"` would convert to `CLOSED` (of `OpenClosedType`).'
|
|
|
|
|
In case all conversions fail, the command is discarded and nothing is written to the Modbus slave.
|
|
|
|
|
5. Next step depends on the `writeType`:
|
|
|
|
|
* `writeType="coil"`: the command from the transformation is converted to boolean. Non-zero numbers, `ON`, and `OPEN` are considered `true`; and rest as `false`.
|
|
|
|
|
* `writeType="holding"`: First, the command from the transformation is converted `1`/`0` number in case of `OPEN`/`ON` or `CLOSED`/`OFF`. The number is converted to one or more registers using `writeValueType`. For example, number `3.14` would be converted to two registers when `writeValueType="float32"`: [0x4048, 0xF5C3].
|
|
|
|
|
6. Boolean (`writeType="coil"`) or registers (`writeType="holding"`) are written to the Modbus slave using `FC05`, `FC06`, `FC15`, or `FC16`, depending on the value of `writeMultipleEvenWithSingleRegisterOrCoil`. Write address is specified by `writeStart`.
|
|
|
|
|
* `writeType="coil"`: the command from the transformation is converted to boolean.
|
|
|
|
|
Non-zero numbers, `ON`, and `OPEN` are considered `true`; and rest as `false`.
|
|
|
|
|
* `writeType="holding"`: First, the command from the transformation is converted `1`/`0` number in case of `OPEN`/`ON` or `CLOSED`/`OFF`. The number is converted to one or more registers using `writeValueType`.
|
|
|
|
|
For example, number `3.14` would be converted to two registers when `writeValueType="float32"`: [0x4048, 0xF5C3].
|
|
|
|
|
6. Boolean (`writeType="coil"`) or registers (`writeType="holding"`) are written to the Modbus slave using `FC05`, `FC06`, `FC15`, or `FC16`, depending on the value of `writeMultipleEvenWithSingleRegisterOrCoil`.
|
|
|
|
|
Write address is specified by `writeStart`.
|
|
|
|
|
|
|
|
|
|
#### Advanced Write Using JSON
|
|
|
|
|
|
|
|
|
|
There are some more advanced use cases which need more control how the command is converted to set of bits or requests.
|
|
|
|
|
Due to this reason, one can return a special [JSON](https://en.wikipedia.org/wiki/JSON) output from the transformation (step 3).
|
|
|
|
|
The JSON directly specifies the write requests to send to Modbus slave. In this case, steps 4. and 5. are skipped.
|
|
|
|
|
The JSON directly specifies the write requests to send to Modbus slave.
|
|
|
|
|
In this case, steps 4. and 5. are skipped.
|
|
|
|
|
|
|
|
|
|
For example, if the transformation returns the following JSON
|
|
|
|
|
|
|
|
|
@ -487,7 +500,8 @@ For example, if the transformation returns the following JSON
|
|
|
|
|
Two write requests would be sent to the Modbus slave
|
|
|
|
|
|
|
|
|
|
1. FC16 (write multiple holding register), with start address 5412, having three registers of data (1, 0, and 5).
|
|
|
|
|
2. FC06 (write single holding register), with start address 555, and single register of data (3). Write is tried maximum of 10 times in case some of the writes fail.
|
|
|
|
|
2. FC06 (write single holding register), with start address 555, and single register of data (3).
|
|
|
|
|
Write is tried maximum of 10 times in case some of the writes fail.
|
|
|
|
|
|
|
|
|
|
The JSON transformation output can be useful when you need full control how the write goes, for example in case where the write address depends on the incoming command.
|
|
|
|
|
Actually, you can omit specifying `writeStart`, `writeValueType` and `writeType` with JSON transformation output altogether.
|
|
|
|
@ -514,7 +528,8 @@ Note that transformation is only one part of the overall process how polled data
|
|
|
|
|
Consult [Read steps](#read-steps) and [Write steps](#write-steps) for more details.
|
|
|
|
|
Specifically, note that you might not need transformations at all in some uses cases.
|
|
|
|
|
|
|
|
|
|
Please also note that you should install relevant transformations, as necessary. For example, `openhab-transformation-javascript` feature provides the javascript (`JS`) transformation.
|
|
|
|
|
Please also note that you should install relevant transformations in openHAB as necessary.
|
|
|
|
|
For example, `openhab-transformation-javascript` feature provides the javascript (`JS`) transformation.
|
|
|
|
|
|
|
|
|
|
#### Transform On Read
|
|
|
|
|
|
|
|
|
@ -580,9 +595,9 @@ In this case, boolean input is considered to be either number `0`/`1`, `ON`/`OFF
|
|
|
|
|
// function to invert Modbus binary states
|
|
|
|
|
// variable "input" contains data passed by OpenHAB binding
|
|
|
|
|
(function(inputData) {
|
|
|
|
|
var out = inputData ; // allow Undefined to pass through
|
|
|
|
|
var out = inputData ; // allow UNDEF to pass through
|
|
|
|
|
if (inputData == '1' || inputData == 'ON' || inputData == 'OPEN') {
|
|
|
|
|
out = '0' ;
|
|
|
|
|
out = '0' ; // change to OFF or OPEN depending on your Item type
|
|
|
|
|
} else if (inputData == '0' || inputData == 'OFF' || inputData == 'CLOSED') {
|
|
|
|
|
out = '1' ;
|
|
|
|
|
}
|
|
|
|
@ -742,7 +757,7 @@ sitemap modbus_ex2 label="modbus_ex2"
|
|
|
|
|
|
|
|
|
|
### Scaling Example
|
|
|
|
|
|
|
|
|
|
This example divides value on read, and multiplies them on write.
|
|
|
|
|
This example divides value on read, and multiplies them on write, using JS transforms.
|
|
|
|
|
|
|
|
|
|
`things/modbus_ex_scaling.things`:
|
|
|
|
|
|
|
|
|
@ -1018,9 +1033,9 @@ Old binding had converted the input based on item type.
|
|
|
|
|
The old binding had `trigger` parameter in item configuration to react only to some openHAB commands, or to some polled states.
|
|
|
|
|
There is no trigger anymore but one can use transformations to accomplish the same thing. See [Transformations](#transformations) for examples.
|
|
|
|
|
|
|
|
|
|
### Support For 32 Bit Value Types In Writing
|
|
|
|
|
### Support For 32, 64 Bit Value Types In Writing
|
|
|
|
|
|
|
|
|
|
The new binding supports 32 bit values types when writing.
|
|
|
|
|
The new binding supports 32 and 64 bit values types when writing.
|
|
|
|
|
|
|
|
|
|
### How to manually migrate
|
|
|
|
|
|
|
|
|
|