Update ZWave documentation (#695)

Signed-off-by: Chris Jackson <chris@cd-jackson.com>
pull/696/head
Chris Jackson 2018-06-03 14:57:15 +01:00 committed by Kai Kreuzer
parent 76a85507d9
commit 33824acf63
744 changed files with 11087 additions and 7056 deletions

View File

@ -8,7 +8,7 @@ title: 45602 - ZWave
# 45602 Lamp Module with Dimmer Control
This describes the Z-Wave device *45602*, manufactured by *ACT - Advanced Control Technologies* with the thing type UID of ```act_45602_00_000```.
The 45602 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The 45602 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the 45602
The following table summarises the channels available for the 45602 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,7 +27,6 @@ The following table summarises the channels available for the 45602
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
@ -188,7 +187,7 @@ The device does not support associations.
### Documentation Links
* [GE 45602 Lamp Dimmer](https://www.cd-jackson.com/zwave_device_uploads/338/45602-UsersGuide.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/338/45602-UsersGuide.pdf)
---

View File

@ -8,7 +8,7 @@ title: ZDM230 - ZWave
# ZDM230 HomePro Wall Dimmer ZDM230
This describes the Z-Wave device *ZDM230*, manufactured by *ACT - Advanced Control Technologies* with the thing type UID of ```act_zdm230_00_000```.
The ZDM230 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZDM230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ Radio Frequency (RF) Controlled, 500W, 230 VAC, European Wall Mounted, 3-Way Dim
## Channels
The following table summarises the channels available for the ZDM230
The following table summarises the channels available for the ZDM230 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,7 +27,6 @@ The following table summarises the channels available for the ZDM230
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.

View File

@ -8,7 +8,7 @@ title: ZDP200 - ZWave
# ZDP200 HomePro ZDP200 Wall Dimmer
This describes the Z-Wave device *ZDP200*, manufactured by *ACT - Advanced Control Technologies* with the thing type UID of ```act_zdp200_00_000```.
The ZDP200 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZDP200 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -22,7 +22,7 @@ Use Habmin or another zwave tool to exclude the device from the zwave mesh.
## Channels
The following table summarises the channels available for the ZDP200
The following table summarises the channels available for the ZDP200 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -33,7 +33,6 @@ The following table summarises the channels available for the ZDP200
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZDW103*, manufactured by *ACT - Advanced Contr
![ZDW103 product image](https://www.cd-jackson.com/zwave_device_uploads/463/463_default.jpg)
The ZDW103 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZDW103 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the ZDW103
The following table summarises the channels available for the ZDW103 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,7 +30,6 @@ The following table summarises the channels available for the ZDW103
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
@ -349,7 +348,7 @@ This group supports 5 nodes.
### Documentation Links
* [Specifications](https://www.cd-jackson.com/zwave_device_uploads/463/ZDW103-spec.pdf)
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/463/ZDW103-instr.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/463/ZDW103-instr.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZDW120*, manufactured by *ACT - Advanced Contr
![ZDW120 product image](https://www.cd-jackson.com/zwave_device_uploads/460/460_default.jpg)
The ZDW120 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZDW120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the ZDW120
The following table summarises the channels available for the ZDW120 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,7 +30,6 @@ The following table summarises the channels available for the ZDW120
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
@ -315,7 +314,7 @@ This group supports 5 nodes.
### Documentation Links
* [Specifications](https://www.cd-jackson.com/zwave_device_uploads/460/ZDW120-spec.pdf)
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/460/ZDW120-instr.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/460/ZDW120-instr.pdf)
---

View File

@ -8,24 +8,27 @@ title: ZIR010 - ZWave
# ZIR010 PIR Motion Sensor
This describes the Z-Wave device *ZIR010*, manufactured by *ACT - Advanced Control Technologies* with the thing type UID of ```act_zir010_00_000```.
The ZIR010 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZIR010 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/189) to improve the documentation.
## Channels
The following table summarises the channels available for the ZIR010
The following table summarises the channels available for the ZIR010 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Binary Sensor | sensor_binary | Door | Switch |
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -38,8 +41,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -54,7 +56,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -149,14 +151,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZRM230*, manufactured by *ACT - Advanced Contr
![ZRM230 product image](https://www.cd-jackson.com/zwave_device_uploads/188/188_default.gif)
The ZRM230 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZRM230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -32,7 +32,7 @@ Including to the Network (Must be installed in permanent location, not on test b
## Channels
The following table summarises the channels available for the ZRM230
The following table summarises the channels available for the ZRM230 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -41,7 +41,7 @@ The following table summarises the channels available for the ZRM230
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -50,7 +50,6 @@ The ```switch_binary``` channel supports the ```Switch``` item and is in the ```
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
@ -242,7 +241,7 @@ This group supports 5 nodes.
### Documentation Links
* [Instruction](https://www.cd-jackson.com/zwave_device_uploads/188/ZRM230-instr.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/188/ZRM230-instr.pdf)
* [Specification Sheet](https://www.cd-jackson.com/zwave_device_uploads/188/ZRM230-spec.pdf)
---

View File

@ -8,7 +8,7 @@ title: ZRP200 - ZWave
# ZRP200 HomePro Applicance Module ZRP200
This describes the Z-Wave device *ZRP200*, manufactured by *ACT - Advanced Control Technologies* with the thing type UID of ```act_zrp200_00_000```.
The ZRP200 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZRP200 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -24,7 +24,7 @@ Use Habmin or another zwave tool to exclude the device from the zwave mesh.
## Channels
The following table summarises the channels available for the ZRP200
The following table summarises the channels available for the ZRP200 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -32,7 +32,7 @@ The following table summarises the channels available for the ZRP200
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -64,7 +64,7 @@ The device does not support associations.
### Documentation Links
* [Installation instructions](https://www.cd-jackson.com/zwave_device_uploads/360/ZRP200-instr.pdf)
* [Device specificatinos](https://www.cd-jackson.com/zwave_device_uploads/360/ZRP200-spec.pdf)
* [Device Specifications](https://www.cd-jackson.com/zwave_device_uploads/360/ZRP200-spec.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZRW230*, manufactured by *ACT - Advanced Contr
![ZRW230 product image](https://www.cd-jackson.com/zwave_device_uploads/546/546_default.jpg)
The ZRW230 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZRW230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -43,7 +43,7 @@ There are no field repairable assemblies on this unit.. If service is needed, th
## Channels
The following table summarises the channels available for the ZRW230
The following table summarises the channels available for the ZRW230 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -51,7 +51,7 @@ The following table summarises the channels available for the ZRW230
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZTM230*, manufactured by *ACT - Advanced Contr
![ZTM230 product image](https://www.cd-jackson.com/zwave_device_uploads/524/524_default.gif)
The ZTM230 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZTM230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -32,7 +32,7 @@ Including to the Network (Must be installed in its permanent location, not on te
## Channels
The following table summarises the channels available for the ZTM230
The following table summarises the channels available for the ZTM230 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -41,7 +41,7 @@ The following table summarises the channels available for the ZTM230
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -50,7 +50,6 @@ The ```switch_binary``` channel supports the ```Switch``` item and is in the ```
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.

View File

@ -8,13 +8,15 @@ title: DSA03202 - ZWave
# DSA03202 Minimote 4 button remote control
This describes the Z-Wave device *DSA03202*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsa03202_00_000```.
The DSA03202 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/74) to improve the documentation.
## Channels
The following table summarises the channels available for the DSA03202
The following table summarises the channels available for the DSA03202 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -22,7 +24,7 @@ The following table summarises the channels available for the DSA03202
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
@ -239,14 +241,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -293,7 +295,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/74/Aeon-Labs-Minimote---Engineering-Spec.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/74/Aeon-Labs-Minimote---Engineering-Spec.pdf)
---

View File

@ -11,22 +11,24 @@ This describes the Z-Wave device *DSA38*, manufactured by *[AEON Labs](http://ae
![DSA38 product image](https://www.cd-jackson.com/zwave_device_uploads/88/88_default.jpg)
The DSA38 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/88) to improve the documentation.
## Channels
The following table summarises the channels available for the DSA38
The following table summarises the channels available for the DSA38 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Scene Number | scene_number | | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
@ -34,7 +36,7 @@ The ```scene_number``` channel supports the ```Number``` item.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -72,14 +74,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -113,7 +115,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/88/5-Panic-Button.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/88/5-Panic-Button.pdf)
---

View File

@ -13,7 +13,7 @@ The device is in the category of *Motion Detector*, defining Motion sensors/dete
![DSB05 product image](https://www.cd-jackson.com/zwave_device_uploads/71/71_default.jpg)
The DSB05 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSB05 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSB05
The following table summarises the channels available for the DSB05 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -29,12 +29,11 @@ The following table summarises the channels available for the DSB05
| Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Sensor (luminance) | sensor_luminance | Temperature | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -47,19 +46,19 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
@ -67,7 +66,7 @@ The ```sensor_luminance``` channel supports the ```Number``` item and is in the
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -272,14 +271,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -314,7 +313,7 @@ This group supports 5 nodes.
### Documentation Links
* [Multi sensor 4 in 1](https://www.cd-jackson.com/zwave_device_uploads/71/25-MultiSensor.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/71/25-MultiSensor.pdf)
---

View File

@ -8,7 +8,7 @@ title: DSB09 - ZWave
# DSB09 Home Energy Meter
This describes the Z-Wave device *DSB09*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsb09_00_000```.
The DSB09 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSB09 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSB09
The following table summarises the channels available for the DSB09 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -24,7 +24,7 @@ The following table summarises the channels available for the DSB09
| Electric meter (kWh) | meter_kwh | Energy | Number |
| Electric meter (watts) | meter_watts | Energy | Number |
| Reset Meter | meter_reset | Energy | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
| Sensor (power) 1 | sensor_power1 | Energy | Number |
| Electric meter (kWh) 1 | meter_kwh1 | Energy | Number |
| Electric meter (watts) 1 | meter_watts1 | Energy | Number |
@ -37,25 +37,25 @@ The following table summarises the channels available for the DSB09
### Sensor (power)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.
@ -63,59 +63,59 @@ The ```meter_reset``` channel supports the ```Switch``` item and is in the ```En
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
### Sensor (power) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 1
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (power) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 2
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (power) 3
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 3
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 3
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -508,7 +508,7 @@ This group supports 5 nodes.
### Documentation Links
* [Aeon Labs HEM Advanced Functions for Developers (SW Version: 3.58+)](https://www.cd-jackson.com/zwave_device_uploads/84/26-Home-Energy-Meter-G1.pdf)
* [Advanced Functions for Developers (SW Version: 3.58+)](https://www.cd-jackson.com/zwave_device_uploads/84/26-Home-Energy-Meter-G1.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *DSB28*, manufactured by *[AEON Labs](http://ae
![DSB28 product image](https://www.cd-jackson.com/zwave_device_uploads/85/85_default.jpg)
The DSB28 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSB28 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSB28
The following table summarises the channels available for the DSB28 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -43,103 +43,103 @@ The following table summarises the channels available for the DSB28
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.
### Electric meter (watts) 1
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 1
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 1
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 2
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 2
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 2
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 3
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 3
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 3
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 3
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,24 +8,27 @@ title: DSB29 - ZWave
# DSB29 Door/Window sensor Gen2
This describes the Z-Wave device *DSB29*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsb29_00_000```.
The DSB29 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DSB29 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/70) to improve the documentation.
## Channels
The following table summarises the channels available for the DSB29
The following table summarises the channels available for the DSB29 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Binary Sensor | sensor_door | Door | Contact |
| Alarm (general) | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -38,8 +41,7 @@ The following state translation is provided for this channel to the ```Contact``
### Alarm (general)
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -54,7 +56,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -170,14 +172,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -212,7 +214,7 @@ This group supports 5 nodes.
### Documentation Links
* [Gen 2 Door/Window sensor doc](https://www.cd-jackson.com/zwave_device_uploads/70/G2-Door-Window-Sensor.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/70/G2-Door-Window-Sensor.pdf)
---

View File

@ -11,6 +11,10 @@ This describes the Z-Wave device *DSB45*, manufactured by *[AEON Labs](http://ae
![DSB45 product image](https://www.cd-jackson.com/zwave_device_uploads/92/92_default.jpg)
The DSB45 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DSB45 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
### Wakeup Information
@ -30,18 +34,17 @@ There are 3 ways to exit the Wake up 10 minutes state:
## Channels
The following table summarises the channels available for the DSB45
The following table summarises the channels available for the DSB45 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Binary Sensor | sensor_binary | Door | Switch |
| Flood Alarm | alarm_flood | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -54,8 +57,7 @@ The following state translation is provided for this channel to the ```Switch```
### Flood Alarm
Indicates if the flood alarm is triggered
Indicates if the flood alarm is triggered.
The ```alarm_flood``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -70,7 +72,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -190,14 +192,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -232,7 +234,7 @@ This group supports 5 nodes.
### Documentation Links
* [Aeon Labs Water Sensor DSB45-ZWUS](https://www.cd-jackson.com/zwave_device_uploads/92/Engineering-Spec---Aeon-Labs-Water-Sensor-V1-02.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/92/Engineering-Spec---Aeon-Labs-Water-Sensor-V1-02.pdf)
---

View File

@ -10,23 +10,26 @@ This describes the Z-Wave device *DSB54*, manufactured by *[AEON Labs](http://ae
The device is in the category of *Door*, defining Door sensors.
The DSB54 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DSB54 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/68) to improve the documentation.
## Channels
The following table summarises the channels available for the DSB54
The following table summarises the channels available for the DSB54 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Sensor | sensor_door | Door | Contact |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Door Sensor
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -41,7 +44,7 @@ The following state translation is provided for this channel to the ```Contact``
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -171,14 +174,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -13,7 +13,7 @@ The device is in the category of *Power Outlet*, defining Small devices to be pl
![DSC06 product image](https://www.cd-jackson.com/zwave_device_uploads/75/75_default.jpg)
The DSC06 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC06
The following table summarises the channels available for the DSC06 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -32,25 +32,25 @@ The following table summarises the channels available for the DSC06
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Sensor (power)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -351,7 +351,7 @@ This group supports 5 nodes.
### Documentation Links
* [Smart Energy Switch v1](https://www.cd-jackson.com/zwave_device_uploads/75/Engineering-Spec---Aeon-Labs-Smart-Energy-Switch-v1.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/75/Engineering-Spec---Aeon-Labs-Smart-Energy-Switch-v1.pdf)
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/75/AEDSC06106ZWUS-Manual.pdf)
---

View File

@ -8,7 +8,7 @@ title: DSC08 - ZWave
# DSC08 Smart Energy Illuminator
This describes the Z-Wave device *DSC08*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc08_00_000```.
The DSC08 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC08
The following table summarises the channels available for the DSC08 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,24 +30,23 @@ The following table summarises the channels available for the DSC08
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Sensor (power)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,7 +8,7 @@ title: DSC10 - ZWave
# DSC10 Heavy Duty Smart Switch
This describes the Z-Wave device *DSC10*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc10_00_000```.
The DSC10 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC10 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC10
The following table summarises the channels available for the DSC10 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -24,7 +24,7 @@ The following table summarises the channels available for the DSC10
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.

View File

@ -10,7 +10,7 @@ This describes the Z-Wave device *DSC11*, manufactured by *[AEON Labs](http://ae
The device is in the category of *Light Bulb*, defining Devices that illuminate something, such as bulbs, etc..
The DSC11 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC11 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -20,7 +20,7 @@ METER:6 :: ADD
## Channels
The following table summarises the channels available for the DSC11
The following table summarises the channels available for the DSC11 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -55,157 +55,157 @@ The following table summarises the channels available for the DSC11
Entire strip
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) entire strip
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) entire strip
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 1
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 1
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 1
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 2
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 2
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 2
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 3
Switch the power on and off
Switch the power on and off.
The ```switch_binary3``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 3
Switch the power on and off
Switch the power on and off.
The ```switch_binary3``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 3
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 3
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 4
Switch the power on and off
Switch the power on and off.
The ```switch_binary4``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 4
Switch the power on and off
Switch the power on and off.
The ```switch_binary4``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 4
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh4``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 4
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts4``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 5
Switch the power on and off
Switch the power on and off.
The ```switch_binary5``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 5
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh5``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 5
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts5``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 6
Switch the power on and off
Switch the power on and off.
The ```switch_binary6``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 6
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh6``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 6
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts6``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -770,7 +770,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec Aeon Smart Strip US](https://www.cd-jackson.com/zwave_device_uploads/89/Engineering-Spec---Aeon-Labs-Smart-Strip-US-Version.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/89/Engineering-Spec---Aeon-Labs-Smart-Strip-US-Version.pdf)
* [V2 of US Smart Strip document](https://www.cd-jackson.com/zwave_device_uploads/89/8-Smart-Strip-US.pdf)
---

View File

@ -8,7 +8,7 @@ title: DSC12 - ZWave
# DSC12 Micro Smart Energy Switch
This describes the Z-Wave device *DSC12*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc12_00_000```.
The DSC12 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC12 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC12
The following table summarises the channels available for the DSC12 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,25 +27,25 @@ The following table summarises the channels available for the DSC12
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Sensor (power)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,7 +8,7 @@ title: DSC13 - ZWave
# DSC13 Micro Smart Energy Illuminator
This describes the Z-Wave device *DSC13*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc13_00_000```.
The DSC13 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC13 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC13
The following table summarises the channels available for the DSC13 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,24 +30,23 @@ The following table summarises the channels available for the DSC13
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Sensor (power)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,7 +8,7 @@ title: DSC14 - ZWave
# DSC14 Micro Motor Controller
This describes the Z-Wave device *DSC14*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc14_00_000```.
The DSC14 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC14 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC14
The following table summarises the channels available for the DSC14 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -25,7 +25,7 @@ The following table summarises the channels available for the DSC14
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -34,7 +34,6 @@ The ```switch_binary``` channel supports the ```Switch``` item and is in the ```
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.

View File

@ -8,7 +8,7 @@ title: DSC17 - ZWave
# DSC17 Micro Double Smart Switch
This describes the Z-Wave device *DSC17*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc17_00_000```.
The DSC17 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC17 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC17
The following table summarises the channels available for the DSC17 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,43 +30,43 @@ The following table summarises the channels available for the DSC17
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Sensor (power)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```sensor_power``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.
### Switch 1
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 2
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -410,7 +410,7 @@ This group supports 5 nodes.
### Documentation Links
* [AEON DSC17 Micro Double Smart Switch Engineering Manual](https://www.cd-jackson.com/zwave_device_uploads/81/13-Micro-Double-Smart-Switch.pdf)
* [Engineering Manual](https://www.cd-jackson.com/zwave_device_uploads/81/13-Micro-Double-Smart-Switch.pdf)
---

View File

@ -8,7 +8,7 @@ title: DSC18 - ZWave
# DSC18 Micro Smart Energy Switch G2
This describes the Z-Wave device *DSC18*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc18_00_000```.
The DSC18 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC18 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC18
The following table summarises the channels available for the DSC18 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -29,37 +29,37 @@ The following table summarises the channels available for the DSC18
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *DSC19*, manufactured by *[AEON Labs](http://ae
![DSC19 product image](https://www.cd-jackson.com/zwave_device_uploads/79/79_default.jpg)
The DSC19 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC19 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -27,7 +27,7 @@ Remove Smart Switch from an existing ZWave network: 1. Installed Micro Smart
## Channels
The following table summarises the channels available for the DSC19
The following table summarises the channels available for the DSC19 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -43,36 +43,35 @@ The following table summarises the channels available for the DSC19
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric Meter (kVah)
Indicates the energy consumption (kVAh)
Indicates the energy consumption (kVAh).
The ```meter_kvah``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -329,8 +328,8 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering specification](https://www.cd-jackson.com/zwave_device_uploads/79/z-wave-aeon-labs-micro-smart-energy-illuminator-engineering-specification-1-.pdf)
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/79/Micro-20Smart-20Energy-20Illuminator-20G2-1-.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/79/z-wave-aeon-labs-micro-smart-energy-illuminator-engineering-specification-1-.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/79/Micro-20Smart-20Energy-20Illuminator-20G2-1-.pdf)
* [Z-Wave Protocol Implementation Conformance Statement](https://www.cd-jackson.com/zwave_device_uploads/79/ZC08-13030005.pdf)
---

View File

@ -13,7 +13,7 @@ The device is in the category of *Power Outlet*, defining Small devices to be pl
![DSC24 product image](https://www.cd-jackson.com/zwave_device_uploads/76/76_default.jpg)
The DSC24 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC24 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC24
The following table summarises the channels available for the DSC24 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -35,43 +35,43 @@ The following table summarises the channels available for the DSC24
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.

View File

@ -8,13 +8,15 @@ title: DSC25 - ZWave
# DSC25 Smart Energy Illuminator G2
This describes the Z-Wave device *DSC25*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc25_00_000```.
The DSC25 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/276) to improve the documentation.
## Channels
The following table summarises the channels available for the DSC25
The following table summarises the channels available for the DSC25 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -25,7 +27,6 @@ The following table summarises the channels available for the DSC25
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.

View File

@ -10,7 +10,7 @@ This describes the Z-Wave device *DSC26*, manufactured by *[AEON Labs](http://ae
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The DSC26 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC26 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -18,7 +18,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC26
The following table summarises the channels available for the DSC26 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -26,7 +26,7 @@ The following table summarises the channels available for the DSC26
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.

View File

@ -8,7 +8,7 @@ title: DSC27 - ZWave
# DSC27 Micro Illuminator G2
This describes the Z-Wave device *DSC27*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_dsc27_00_000```.
The DSC27 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC27 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC27
The following table summarises the channels available for the DSC27 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,7 +27,6 @@ The following table summarises the channels available for the DSC27
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.

View File

@ -10,7 +10,7 @@ This describes the Z-Wave device *DSC35*, manufactured by *[AEON Labs](http://ae
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The DSC35 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSC35 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -18,7 +18,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSC35
The following table summarises the channels available for the DSC35 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -28,19 +28,19 @@ The following table summarises the channels available for the DSC35
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 1
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 2
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.

View File

@ -10,7 +10,7 @@ This describes the Z-Wave device *DSD31*, manufactured by *[AEON Labs](http://ae
The device is in the category of *Siren*, defining Siren used by Alarm systems.
The DSD31 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSD31 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -18,7 +18,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSD31
The following table summarises the channels available for the DSD31 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -26,7 +26,7 @@ The following table summarises the channels available for the DSD31
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -161,7 +161,7 @@ This group supports 5 nodes.
### Documentation Links
* [Aeotec Manual](https://www.cd-jackson.com/zwave_device_uploads/86/Siren-Gen5-Manual.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/86/Siren-Gen5-Manual.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *DSD37*, manufactured by *[AEON Labs](http://ae
![DSD37 product image](https://www.cd-jackson.com/zwave_device_uploads/66/66_default.jpg)
The DSD37 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The DSD37 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the DSD37
The following table summarises the channels available for the DSD37 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -107,7 +107,7 @@ This group supports 5 nodes.
### Documentation Links
* [Aeotec Range Extender](https://www.cd-jackson.com/zwave_device_uploads/66/20-Range-Extender--Repeater-.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/66/20-Range-Extender--Repeater-.pdf)
* [Engineering Manual](https://www.cd-jackson.com/zwave_device_uploads/66/z-wave-plus-aeotec-range-extender-engineering-sheet.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZW056*, manufactured by *[AEON Labs](http://ae
![ZW056 product image](https://www.cd-jackson.com/zwave_device_uploads/263/263_default.jpg)
The ZW056 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW056 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -37,7 +37,7 @@ Note: If Doorbell is removed from Z-wave network, it will be reset to factory de
## Channels
The following table summarises the channels available for the ZW056
The following table summarises the channels available for the ZW056 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -50,37 +50,37 @@ The following table summarises the channels available for the ZW056
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Volume
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Repititions
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Play Chime Now
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Doorbell Notifications
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Button Battery Status
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
@ -360,7 +360,7 @@ This group supports 5 nodes.
### Documentation Links
* [English Manual](https://www.cd-jackson.com/zwave_device_uploads/263/Doorbell-manual-20150604-.pdf)
* [English User Manual](https://www.cd-jackson.com/zwave_device_uploads/263/Doorbell-manual-20150604-.pdf)
* [Engineering manual](https://www.cd-jackson.com/zwave_device_uploads/263/aeon-labs-Doorbell-Gen5-engineering-manual.pdf)
---

View File

@ -13,7 +13,7 @@ The device is in the category of *Garage Door*, defining Garage Door.
![ZW062 product image](https://www.cd-jackson.com/zwave_device_uploads/256/256_default.png)
The ZW062 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW062 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -48,7 +48,7 @@ Note: If Garage Door Controller is removed from Z-wave network, it will be reset
## Channels
The following table summarises the channels available for the ZW062
The following table summarises the channels available for the ZW062 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -57,14 +57,13 @@ The following table summarises the channels available for the ZW062
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Barrier State
Indicates the state of the barrier
Indicates the state of the barrier.
The ```barrier_state``` channel supports the ```Number``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -542,7 +541,7 @@ This group supports 5 nodes.
### Documentation Links
* [zw062 Engineering manual](https://www.cd-jackson.com/zwave_device_uploads/256/16-Garage-Door-Controller-Gen5.pdf)
* [Engineering manual](https://www.cd-jackson.com/zwave_device_uploads/256/16-Garage-Door-Controller-Gen5.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/256/z-wave-aeon-labs-garage-door-controller-gen5-manual.pdf)
---

View File

@ -11,13 +11,17 @@ This describes the Z-Wave device *ZW074*, manufactured by *[AEON Labs](http://ae
![ZW074 product image](https://www.cd-jackson.com/zwave_device_uploads/72/72_default.png)
The ZW074 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW074 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/72) to improve the documentation.
## Channels
The following table summarises the channels available for the ZW074
The following table summarises the channels available for the ZW074 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -26,12 +30,11 @@ The following table summarises the channels available for the ZW074
| Sensor (luminance) | sensor_luminance | Temperature | Number |
| Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -44,26 +47,25 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -78,7 +80,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -348,14 +350,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -13,7 +13,7 @@ The device is in the category of *Power Outlet*, defining Small devices to be pl
![ZW075 product image](https://www.cd-jackson.com/zwave_device_uploads/83/83_default.jpg)
The ZW075 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW075 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the ZW075
The following table summarises the channels available for the ZW075 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -34,37 +34,37 @@ The following table summarises the channels available for the ZW075
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.
@ -331,14 +331,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
### Switch All Mode

View File

@ -13,7 +13,7 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![ZW078 product image](https://www.cd-jackson.com/zwave_device_uploads/65/65_default.jpg)
The ZW078 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW078 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -42,7 +42,7 @@ If youre using a Z-Stick:
## Channels
The following table summarises the channels available for the ZW078
The following table summarises the channels available for the ZW078 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -54,31 +54,31 @@ The following table summarises the channels available for the ZW078
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -10,7 +10,7 @@ This describes the Z-Wave device *ZW080*, manufactured by *[AEON Labs](http://ae
The device is in the category of *Siren*, defining Siren used by Alarm systems.
The ZW080 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW080 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -35,7 +35,7 @@ Note: If Siren is removed from Zwave network, it will be reset to factory def
## Channels
The following table summarises the channels available for the ZW080
The following table summarises the channels available for the ZW080 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -44,7 +44,7 @@ The following table summarises the channels available for the ZW080
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -52,7 +52,7 @@ The ```switch_binary``` channel supports the ```Switch``` item and is in the ```
Value 1 (LSB) Sound (bits 0-4), Value 2 (MSB) volume (bits 0-2)
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
@ -183,7 +183,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/90/aeotec-zw080a17-engineering-spec.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/90/aeotec-zw080a17-engineering-spec.pdf)
---

View File

@ -9,6 +9,8 @@ title: ZW088 - ZWave
This describes the Z-Wave device *ZW088*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw088_01_000```.
This version of the device is limited to firmware versions above 1.0
The ZW088 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
Key Fob Gen5 is a fully functional Z-wave remote controller, which can include, exclude and control the other Z-Wave certified devices. It also can be acted a secondary controller in a network.
@ -19,16 +21,16 @@ Short press the “Include” button on the Key Fob, it will go into inclusion s
## Channels
The following table summarises the channels available for the ZW088
The following table summarises the channels available for the ZW088 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Scene Number | scene_number | | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
@ -36,7 +38,7 @@ The ```scene_number``` channel supports the ```Number``` item.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -74,14 +76,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -13,6 +13,10 @@ The device is in the category of *Door*, defining Door sensors.
![ZW089 product image](https://www.cd-jackson.com/zwave_device_uploads/64/64_default.png)
The ZW089 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW089 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
Aeon Labs Recessed Door Sensor Gen5 is a door detector that can detect the state of the door's open/close.
@ -37,18 +41,17 @@ Press and hold the Zwave Button for 6 seconds. It will sleep after you releas
## Channels
The following table summarises the channels available for the ZW089
The following table summarises the channels available for the ZW089 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Status | sensor_door | Door | Contact |
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Door Status
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -61,8 +64,7 @@ The following state translation is provided for this channel to the ```Contact``
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -77,7 +79,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -229,14 +231,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -276,7 +278,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/64/Engineering-Spec---Aeon-Labs-Recessed-Door-Sensor-Gen5-V1-13.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/64/Engineering-Spec---Aeon-Labs-Recessed-Door-Sensor-Gen5-V1-13.pdf)
---

View File

@ -8,7 +8,8 @@ title: ZW090 - ZWave
# ZW090 ZStick Gen5 USB Controller
This describes the Z-Wave device *ZW090*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw090_00_000```.
The ZW090 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
![ZW090 product image](https://www.cd-jackson.com/zwave_device_uploads/265/265_default.png)
## Overview
@ -41,7 +42,7 @@ N/A
## Channels
The following table summarises the channels available for the ZW090
The following table summarises the channels available for the ZW090 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -165,7 +166,7 @@ This group supports 5 nodes.
### Documentation Links
* [Z-stick Gen5 Engineering manual](https://www.cd-jackson.com/zwave_device_uploads/265/1-Z-Stick-Gen5.pdf)
* [Engineering Manual](https://www.cd-jackson.com/zwave_device_uploads/265/1-Z-Stick-Gen5.pdf)
* [Z-Wave Protocol Implementation Conformance Statement - Z-Stick Gen5](https://www.cd-jackson.com/zwave_device_uploads/265/Z-Wave-Protocol-Implementation-Conformance-Statement.pdf)
---

View File

@ -13,7 +13,7 @@ The device is in the category of *Sensor*, defining Device used to measure somet
![ZW095 product image](https://www.cd-jackson.com/zwave_device_uploads/375/375_default.jpg)
The ZW095 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW095 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -43,7 +43,7 @@ Security enabled Controller is needed in order to fully use the security feature
## Channels
The following table summarises the channels available for the ZW095
The following table summarises the channels available for the ZW095 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -67,103 +67,103 @@ The following table summarises the channels available for the ZW095
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.
### Electric meter (amps) 1
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 1
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 1
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 2
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 2
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 2
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 3
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 3
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 3
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 3
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -13,7 +13,7 @@ The device is in the category of *Power Outlet*, defining Small devices to be pl
![ZW096 product image](https://www.cd-jackson.com/zwave_device_uploads/63/63_default.jpg)
The ZW096 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW096 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -61,7 +61,7 @@ mains device
## Channels
The following table summarises the channels available for the ZW096
The following table summarises the channels available for the ZW096 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -75,37 +75,37 @@ The following table summarises the channels available for the ZW096
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Reset Meter
Reset the meter
Reset the meter.
The ```meter_reset``` channel supports the ```Switch``` item and is in the ```Energy``` category.
@ -114,7 +114,6 @@ The ```meter_reset``` channel supports the ```Switch``` item and is in the ```En
The color channel allows to control the color of a light.
It is also possible to dim values and switch the light on and off.
The ```color_color``` channel supports the ```Color``` item.
@ -605,7 +604,7 @@ This group supports 5 nodes.
### Documentation Links
* [Smart Switch 6](https://www.cd-jackson.com/zwave_device_uploads/63/3-Smart-Switch-6.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/63/3-Smart-Switch-6.pdf)
---

View File

@ -8,13 +8,17 @@ title: ZW097 - ZWave
# ZW097 Dry Contact Sensor
This describes the Z-Wave device *ZW097*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw097_00_000```.
The ZW097 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW097 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/267) to improve the documentation.
## Channels
The following table summarises the channels available for the ZW097
The following table summarises the channels available for the ZW097 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,12 +34,11 @@ The following table summarises the channels available for the ZW097
| Alarm (system) | alarm_system | | Switch |
| Alarm (emergency) | alarm_emergency | Door | Switch |
| Alarm (clock) | alarm_clock | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -48,8 +51,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (smoke)
Indicates if a smoke is triggered
Indicates if a smoke is triggered.
The ```alarm_smoke``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -62,8 +64,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (CO)
Indicates if the carbon monoxide alarm is triggered
Indicates if the carbon monoxide alarm is triggered.
The ```alarm_co``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -76,8 +77,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (CO2)
Indicates if the carbon dioxide alarm is triggered
Indicates if the carbon dioxide alarm is triggered.
The ```alarm_co2``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -90,8 +90,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -104,8 +103,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (water)
Indicates if the flood alarm is triggered
Indicates if the flood alarm is triggered.
The ```alarm_flood``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -118,8 +116,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (access control)
Indicates if the access control alarm is triggered
Indicates if the access control alarm is triggered.
The ```alarm_access``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -132,8 +129,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (burglar)
Indicates if the burglar alarm is triggered
Indicates if the burglar alarm is triggered.
The ```alarm_burglar``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -146,8 +142,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (power)
Indicates if a power alarm is triggered
Indicates if a power alarm is triggered.
The ```alarm_power``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -160,8 +155,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (system)
Indicates if a system alarm is triggered
Indicates if a system alarm is triggered.
The ```alarm_system``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -174,8 +168,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (emergency)
Indicates if the emergency alarm is triggered
Indicates if the emergency alarm is triggered.
The ```alarm_emergency``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -188,8 +181,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (clock)
Indicates if the clock alarm is triggered
Indicates if the clock alarm is triggered.
The ```alarm_clock``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -204,7 +196,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -351,14 +343,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -399,7 +391,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/267/Dry-Contact-Sensor-Gen5-manual.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/267/Dry-Contact-Sensor-Gen5-manual.pdf)
---

View File

@ -13,7 +13,7 @@ The device is in the category of *Light Bulb*, defining Devices that illuminate
![ZW098 product image](https://www.cd-jackson.com/zwave_device_uploads/91/91_default.jpg)
The ZW098 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW098 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -44,7 +44,7 @@ Note: If LED Bulb has been successfully excluded from your Z-Wave network, its w
## Channels
The following table summarises the channels available for the ZW098
The following table summarises the channels available for the ZW098 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -57,7 +57,6 @@ The following table summarises the channels available for the ZW098
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Color Control
@ -65,7 +64,6 @@ The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```
The color channel allows to control the color of a light.
It is also possible to dim values and switch the light on and off.
The ```color_color``` channel supports the ```Color``` item.
### Color Temperature
@ -560,7 +558,7 @@ This group supports 5 nodes.
### Documentation Links
* [ZW098 LED bulb engineering document](https://www.cd-jackson.com/zwave_device_uploads/91/13-LED-Bulb.pdf)
* [Engineering Manual](https://www.cd-jackson.com/zwave_device_uploads/91/13-LED-Bulb.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZW099*, manufactured by *[AEON Labs](http://ae
![ZW099 product image](https://www.cd-jackson.com/zwave_device_uploads/275/275_default.png)
The ZW099 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW099 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -37,7 +37,7 @@ Endpoint 2 is used to Set/Get the brightness level of RGB LED when it is in Nigh
## Channels
The following table summarises the channels available for the ZW099
The following table summarises the channels available for the ZW099 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -51,18 +51,17 @@ The following table summarises the channels available for the ZW099
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Power Consumption (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Energy Consumption (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -71,7 +70,6 @@ The ```meter_watts``` channel supports the ```Number``` item and is in the ```En
The color channel allows to control the color of a light.
It is also possible to dim values and switch the light on and off.
The ```color_color``` channel supports the ```Color``` item.
@ -534,7 +532,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/275/Aeon-Labs-Smart-Dimmer-6.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/275/Aeon-Labs-Smart-Dimmer-6.pdf)
---

View File

@ -14,7 +14,7 @@ The device is in the category of *Sensor*, defining Device used to measure somet
![ZW100 product image](https://www.cd-jackson.com/zwave_device_uploads/73/73_default.png)
The ZW100 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -22,7 +22,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the ZW100
The following table summarises the channels available for the ZW100 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -32,12 +32,11 @@ The following table summarises the channels available for the ZW100
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Sensor (luminance) | sensor_luminance | Temperature | Number |
| Alarm (general) | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Sensor (motion)
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -50,32 +49,31 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (ultraviolet)
Indicates the current ultraviolet level
Indicates the current ultraviolet level.
The ```sensor_ultraviolet``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (general)
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -90,7 +88,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -547,14 +545,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -600,7 +598,7 @@ This group supports 5 nodes.
### Documentation Links
* [MultiSensor 6](https://www.cd-jackson.com/zwave_device_uploads/73/9-MultiSensor-6.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/73/9-MultiSensor-6.pdf)
---

View File

@ -9,9 +9,11 @@ title: ZW100 - ZWave
This describes the Z-Wave device *ZW100*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw100_01_010```.
This version of the device is limited to firmware versions above 1.10
The device is in the category of Sensor, defining Device used to measure something.
The device is in the category of *Sensor*, defining Device used to measure something.
# Overview
The ZW100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
RESET - Press and hold for 20 seconds
@ -27,7 +29,7 @@ RESET - Press and hold for 20 seconds
b), delete the Association settings;
c), restore the Configuration settings to the default.
## Inclusion Information
### Inclusion Information
Click one time
==============
@ -56,7 +58,7 @@ Short press 2 times within 1 second
press the Action Button. If the LED is still in slow blink, in which you need to repeat the process from
step 2.
## Exclusion Information
### Exclusion Information
Remove MultiSensor from Z-wave network:
1\. Power on MultiSensor. The MultiSensors LED will be kept turning on for 8 seconds when you short
@ -66,7 +68,7 @@ press the Action Button.
4\. If the exclusion is success, MultiSensors LED will blink slowly when you short press the Action
Button. If MultiSensors LED still keeps on status, in which you need to repeat the process from step 2.
## Wakeup Information
### Wakeup Information
Press and hold for 3 seconds
============================
@ -76,7 +78,7 @@ Enable/disable wake up for 10 minutes.
## Channels
The following table summarises the channels available for the ZW100
The following table summarises the channels available for the ZW100 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -87,11 +89,11 @@ The following table summarises the channels available for the ZW100
| Sensor (relative humidity) | sensor_relhumidity | Humidity | Number |
| Motion Alarm | alarm_motion | Door | Switch |
| Tamper Alarm | alarm_tamper | | Switch |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -104,32 +106,31 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (ultraviolet)
Indicates the current ultraviolet level
Indicates the current ultraviolet level.
The ```sensor_ultraviolet``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Motion Alarm
Indicates if a motion alarm is triggered
Indicates if a motion alarm is triggered.
The ```alarm_motion``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -142,8 +143,7 @@ The following state translation is provided for this channel to the ```Switch```
### Tamper Alarm
Indicates if the tamper alarm is triggered
Indicates if the tamper alarm is triggered.
The ```alarm_tamper``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -154,6 +154,12 @@ The following state translation is provided for this channel to the ```Switch```
| OFF | Ok |
| ON | Alarm |
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
## Device Configuration
@ -217,6 +223,8 @@ Detailed information on each parameter can be found in the sections below.
| 204 | Ultraviolet Sensor Calibration | Ultraviolet Sensor Calibration |
| 252 | Lock Configuration Parameters | Enable or Disable changing of configuration parameters |
| 255 | Reset to default factory settings | |
| | Wakeup Interval | Sets the interval at which the device will accept commands from the controller |
| | Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
### Parameter 2: Stay Awake in Battery Mode
@ -231,7 +239,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```.
@ -251,7 +259,7 @@ Motion Sensor reset timeout
3. Other values will be ignored.
Values in the range 10 to 3600 may be set.
The manufacturer defined default value is 240.
The manufacturer defined default value is ```240```.
This parameter has the configuration ID ```config_3_2``` and is of type ```INTEGER```.
@ -271,7 +279,7 @@ The following option values may be configured -:
| 4 | Enable, sensitivity level 4 |
| 5 | Enable, sensitivity level 5 (maximum) |
The manufacturer defined default value is 5 (Enable, sensitivity level 5 (maximum)).
The manufacturer defined default value is ```5``` (Enable, sensitivity level 5 (maximum)).
This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```.
@ -287,7 +295,7 @@ The following option values may be configured -:
| 1 | Send Basic Set CC |
| 2 | Send Sensor Binary Report CC |
The manufacturer defined default value is 1 (Send Basic Set CC).
The manufacturer defined default value is ```1``` (Send Basic Set CC).
This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```.
@ -298,7 +306,7 @@ Set the timeout of awake after the Wake Up CC is sent out...
Values in the range 8 to 255 may be set.
The manufacturer defined default value is 30.
The manufacturer defined default value is ```30```.
This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```.
@ -313,7 +321,7 @@ Value2 (LSB): 0x00=keep sleep state for Battery power mode, 0x01=keep awake for
NOTE: this parameter cannot be used as Get/Set usageThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_9_2``` and is of type ```INTEGER```.
This is a read only parameter.
@ -330,7 +338,7 @@ The following option values may be configured -:
| 0 | Asleep |
| 1 | Awake |
The manufacturer defined default value is 0 (Asleep).
The manufacturer defined default value is ```0``` (Asleep).
This parameter has the configuration ID ```config_9_2_00000001``` and is of type ```INTEGER```.
This is a read only parameter.
@ -347,7 +355,7 @@ The following option values may be configured -:
| 0 | USB |
| 1 | Battery |
The manufacturer defined default value is 0 (USB).
The manufacturer defined default value is ```0``` (USB).
This parameter has the configuration ID ```config_9_2_00000100``` and is of type ```INTEGER```.
This is a read only parameter.
@ -360,7 +368,7 @@ Configure low battery value.
Value=10 to 50.(10% to 50%)
Values in the range 10 to 50 may be set.
The manufacturer defined default value is 20.
The manufacturer defined default value is ```20```.
This parameter has the configuration ID ```config_39_1``` and is of type ```INTEGER```.
@ -378,7 +386,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_40_1``` and is of type ```INTEGER```.
@ -398,7 +406,7 @@ The following option values may be configured -:
|--------|-------------|
| 0 | Temperature Threshold Unit |
The manufacturer defined default value is 20.
The manufacturer defined default value is ```20```.
This parameter has the configuration ID ```config_41_4_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -423,7 +431,7 @@ The following option values may be configured -:
| 1 | Celsius |
| 2 | Fahrenheit |
The manufacturer defined default value is 1 (Celsius).
The manufacturer defined default value is ```1``` (Celsius).
This parameter has the configuration ID ```config_41_4_0000FF00``` and is of type ```INTEGER```.
@ -434,7 +442,7 @@ Threshold change in temperature to induce an automatic report.
It seems that only the lower byte of the upper word is used for temperature threshold.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_41_4_00FF0000``` and is of type ```INTEGER```.
@ -449,7 +457,7 @@ Note:
more than 10%, it will send out a humidity report.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10.
The manufacturer defined default value is ```10```.
This parameter has the configuration ID ```config_42_1``` and is of type ```INTEGER```.
@ -460,7 +468,7 @@ Luminance change threshold
Threshold change in luminance to induce an automatic report.
Values in the range 0 to 1000 may be set.
The manufacturer defined default value is 100.
The manufacturer defined default value is ```100```.
This parameter has the configuration ID ```config_43_2``` and is of type ```INTEGER```.
@ -476,7 +484,7 @@ Note:
more than 10%, it will send out a battery report.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10.
The manufacturer defined default value is ```10```.
This parameter has the configuration ID ```config_44_1``` and is of type ```INTEGER```.
@ -487,7 +495,7 @@ Ultraviolet change threshold
Threshold change in ultraviolet to induce an automatic report.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 2.
The manufacturer defined default value is ```2```.
This parameter has the configuration ID ```config_45_1``` and is of type ```INTEGER```.
@ -509,7 +517,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_46_1``` and is of type ```INTEGER```.
@ -544,7 +552,7 @@ Bit 7 = ultraviolet.
_Note:_ If USB power, the Sensor will check the limit every 10 seconds. If battery power, the Sensor will check the limit when it is waken up.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_48_1``` and is of type ```INTEGER```.
@ -565,7 +573,7 @@ Upper limit range: -40.0 to 100.0 ℃ (0xFE70 to 0x03E8). E.g. The default upper
Upper limit range: -40.0 to 212.0 ℉ (0xFE70 to 0x0848). E.g. The default upper limit of US version is 82.4℉ (0X0338), when the measurement is more than 82.4℉, it will be triggered to send out a temperature sensor report.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_49_4_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -582,7 +590,7 @@ The following option values may be configured -:
| 1 | Celsius |
| 2 | Fahrenheit |
The manufacturer defined default value is 1 (Celsius).
The manufacturer defined default value is ```1``` (Celsius).
This parameter has the configuration ID ```config_49_4_0000FF00_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -602,7 +610,7 @@ E.g. The default upper limit of EU/AU version is 28.0 ℃ (0x0118), when the mea
E.g. The default upper limit of US version is 82.4℉ (0X0338), when the measurement is more than 82.4℉, it will be triggered to send out a temperature sensor report.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 280.
The manufacturer defined default value is ```280```.
This parameter has the configuration ID ```config_49_4_7FFF0000_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -622,7 +630,7 @@ Lower limit range: -40.0 to 100.0 ℃ (0xFE70 to 0x03E8). E.g. The default lower
Upper limit range: -40.0 to 212.0 ℉ (0xFE70 to 0x0848). E.g. The default lower limit of US version is 32.0℉ (0x0140), when the measurement is less than 32.0℉, it will be triggered to send out a temperature sensor report.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_50_4_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -639,7 +647,7 @@ The following option values may be configured -:
| 1 | Celsius |
| 2 | Fahrenheit |
The manufacturer defined default value is 1 (Celsius).
The manufacturer defined default value is ```1``` (Celsius).
This parameter has the configuration ID ```config_50_4_0000FF00_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -659,7 +667,7 @@ E.g. The default lower limit of EU/AU version is 0 ℃ (0x0000), when the measur
E.g. The default lower limit of US version is 32.0℉ (0x0140), when the measurement is less than 32.0℉, it will be triggered to send out a temperature sensor report.
Values in the range 0 to 2678400 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_50_4_7FFF0000_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -671,7 +679,7 @@ Upper limit value of humidity sensor
Set the upper limit value of humidity sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. Upper limit range: 0 to 100%. E.g. The default upper limit is 60%, when the measurement is more than 60%, it will be triggered to send out a humidity sensor report.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 60.
The manufacturer defined default value is ```60```.
This parameter has the configuration ID ```config_51_1``` and is of type ```INTEGER```.
@ -684,7 +692,7 @@ Set the lower limit value of humidity sensor. When the measurement is less than
E.g. The default lower limit is 50%, when the measurement is less than 50%, it will be triggered to send out a humidity sensor report.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 50.
The manufacturer defined default value is ```50```.
This parameter has the configuration ID ```config_52_1``` and is of type ```INTEGER```.
@ -697,7 +705,7 @@ Set the upper limit value of Lighting sensor. When the measurement is more than
E.g. The default upper limit is 1000Lux, when the measurement is more than 1000Lux, it will be triggered to send out a Lighting sensor report.
Values in the range 0 to 30000 may be set.
The manufacturer defined default value is 1000.
The manufacturer defined default value is ```1000```.
This parameter has the configuration ID ```config_53_2``` and is of type ```INTEGER```.
@ -710,7 +718,7 @@ Set the lower limit value of Lighting sensor. When the measurement is less than
E.g. The default lower limit is 100Lux, when the measurement is less than 100Lux, it will be triggered to send out a Lighting sensor report.
Values in the range 0 to 30000 may be set.
The manufacturer defined default value is 100.
The manufacturer defined default value is ```100```.
This parameter has the configuration ID ```config_54_2``` and is of type ```INTEGER```.
@ -723,7 +731,7 @@ Set the upper limit value of ultraviolet sensor. When the measurement is more th
E.g. The default upper limit is 8, when the measurement is more than 8, it will be triggered to send out a ultraviolet sensor report.
Values in the range 1 to 11 may be set.
The manufacturer defined default value is 8.
The manufacturer defined default value is ```8```.
This parameter has the configuration ID ```config_55_1``` and is of type ```INTEGER```.
@ -736,7 +744,7 @@ Set the lower limit value of ultraviolet sensor. When the measurement is less th
E.g. The default lower limit is 4, when the measurement is less than 8, it will be triggered to send out a ultraviolet sensor report.
Values in the range 1 to 11 may be set.
The manufacturer defined default value is 4.
The manufacturer defined default value is ```4```.
This parameter has the configuration ID ```config_56_1``` and is of type ```INTEGER```.
@ -759,7 +767,7 @@ _Note_:
E.g. The default recover limit value is 2.0 ℃/℉ (0x1401/0x1402), when the measurement is less than (Upper limit 2), the upper limit report would be enabled one time or when the measurement is more
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_57_2``` and is of type ```INTEGER```.
@ -780,7 +788,7 @@ _Note_:
E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time.
Values in the range 1 to 50 may be set.
The manufacturer defined default value is 5.
The manufacturer defined default value is ```5```.
This parameter has the configuration ID ```config_58_1``` and is of type ```INTEGER```.
@ -803,7 +811,7 @@ _Note_:
E.g. The default recover limit value is 100 Lux, when the measurement is less than (Upper limit 100), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 100), the lower limit report would be enabled one time.
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 10.
The manufacturer defined default value is ```10```.
This parameter has the configuration ID ```config_59_1``` and is of type ```INTEGER```.
@ -824,7 +832,7 @@ _Note_:
E.g. The default recover limit value is 2, when the measurement is less than (Upper limit 2), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 2), the lower limit report would be enabled one time.
Values in the range 1 to 5 may be set.
The manufacturer defined default value is 2.
The manufacturer defined default value is ```2```.
This parameter has the configuration ID ```config_60_1``` and is of type ```INTEGER```.
@ -857,7 +865,7 @@ Bit 6 = luminance.
Bit 7 = ultraviolet
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_61_1``` and is of type ```INTEGER```.
This is a read only parameter.
@ -869,7 +877,7 @@ Default unit of the automatic temperature report
Set the default unit of the automatic temperature report in parameter 101- 103. 1 = Celsius. 2 = Fahrenheit.
Values in the range 1 to 2 may be set.
The manufacturer defined default value is 1.
The manufacturer defined default value is ```1```.
This parameter has the configuration ID ```config_64_1``` and is of type ```INTEGER```.
@ -889,7 +897,7 @@ The following option values may be configured -:
| 1 | Disable PIR LED |
| 2 | Disable ALL |
The manufacturer defined default value is 0 (Enable LED blinking).
The manufacturer defined default value is ```0``` (Enable LED blinking).
This parameter has the configuration ID ```config_81_1``` and is of type ```INTEGER```.
@ -900,7 +908,7 @@ Reset 101-103 to defaults
Set 101-103 to default.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_100_1_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -920,7 +928,7 @@ This value is a combination number made up of the sum of the values for the indi
1+16+32+64+128 = 241 and is the default value
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 241.
The manufacturer defined default value is ```241```.
This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```.
@ -937,7 +945,7 @@ This value is a combination number made up of the sum of the values for the indi
- Light=128
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_102_4``` and is of type ```INTEGER```.
@ -954,7 +962,7 @@ This value is a combination number made up of the sum of the values for the indi
- Light=128
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_103_4``` and is of type ```INTEGER```.
@ -965,7 +973,7 @@ Set parameters 111-113 to default.
Set parameters 111-113 to default.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_110_1_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -980,7 +988,7 @@ The interval time of sending reports in Report group 1 (Valid values 0x05-0x28DE
2. If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes. You can also change the minimum interval time to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set CC.
Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600.
The manufacturer defined default value is ```3600```.
This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```.
@ -1000,7 +1008,7 @@ to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval
CC.
Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600.
The manufacturer defined default value is ```3600```.
This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```.
@ -1014,7 +1022,7 @@ The interval time of sending reports in Report group 3
2. If battery power, the minimum interval time is 60 minutes by default, for example, if the value is set to be more than 5 and less than 3600, the interval time is 60 minutes, if the value is set to be more than 3600 and less than 7200, the interval time is 120 minutes. You can also change the minimum interval time to 4 minutes via setting the interval value(3 bytes) to 240 in Wake Up Interval Set CC.
Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600.
The manufacturer defined default value is ```3600```.
This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```.
@ -1030,7 +1038,7 @@ Temperature calibration (the available value range is \[-128,127\] or \[-12.8°C
3. The calibration value = standard value - measure value. °C and the standard value = 23.2 °C , so the calibration value= 23.2 °C - 25.3 °C = -2.1 °C (0xEB). If the measure value =30.1 °C and the standard value = 33.2 °C , so the calibration value= 33.2 °C - 30.1 °C =3.1 °C (0x1F).This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range -128 to 127 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_201_2``` and is of type ```INTEGER```.
@ -1046,7 +1054,7 @@ The following option values may be configured -:
| 1 | Celsius |
| 2 | Fahrenheit |
The manufacturer defined default value is 1 (Celsius).
The manufacturer defined default value is ```1``` (Celsius).
This parameter has the configuration ID ```config_201_2_000000FF``` and is of type ```INTEGER```.
@ -1057,7 +1065,7 @@ Calibration value containing one decimal point
Values in the range -127 to 127 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_201_2_0000FF00``` and is of type ```INTEGER```.
@ -1073,7 +1081,7 @@ If the measure value =85RH and the standard value = 90RH, so the calibration
value= 90RH 85RH=5RH (0x05).
Values in the range -50 to 50 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_202_1``` and is of type ```INTEGER```.
@ -1089,7 +1097,7 @@ If the measure value =850Lux and the standard value = 900Lux, so the calibration
value= 900 850=50 (0x0032).
Values in the range -1000 to 1000 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_203_2``` and is of type ```INTEGER```.
@ -1105,7 +1113,7 @@ If the measure value =7 and the standard value = 9, so the calibration value= 9
7=2 (0x02).
Values in the range -10 to 10 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_204_1``` and is of type ```INTEGER```.
@ -1121,7 +1129,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_252_1``` and is of type ```INTEGER```.
@ -1137,11 +1145,28 @@ The following option values may be configured -:
| 1 | Resets all configuration parameters to defaults |
| 1431655765 | Reset to default factory settings and be excluded |
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_255_4_wo``` and is of type ```INTEGER```.
This is a write only parameter.
### Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in *seconds*. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -1189,7 +1214,11 @@ This group supports 5 nodes.
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_VERSION_V2| |
### Documentation Links
* [Engineering sheet updated](https://www.cd-jackson.com/zwave_device_uploads/778/ES---MultiSensor-6-V1-11.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/778).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/778).

View File

@ -14,7 +14,7 @@ The device is in the category of *Sensor*, defining Device used to measure somet
![ZW100 product image](https://www.cd-jackson.com/zwave_device_uploads/355/355_default.png)
The ZW100 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -50,7 +50,7 @@ Press and hold for 20 seconds:
## Channels
The following table summarises the channels available for the ZW100
The following table summarises the channels available for the ZW100 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -61,12 +61,11 @@ The following table summarises the channels available for the ZW100
| Sensor (luminance) | sensor_luminance | Temperature | Number |
| Motion Alarm | alarm_motion | Door | Switch |
| Tamper Alarm | alarm_tamper | | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -79,32 +78,31 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (ultraviolet)
Indicates the current ultraviolet level
Indicates the current ultraviolet level.
The ```sensor_ultraviolet``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Motion Alarm
Indicates if a motion alarm is triggered
Indicates if a motion alarm is triggered.
The ```alarm_motion``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -117,8 +115,7 @@ The following state translation is provided for this channel to the ```Switch```
### Tamper Alarm
Indicates if the tamper alarm is triggered
Indicates if the tamper alarm is triggered.
The ```alarm_tamper``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -133,7 +130,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -672,14 +669,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -14,7 +14,7 @@ The device is in the category of *Sensor*, defining Device used to measure somet
![ZW100 product image](https://www.cd-jackson.com/zwave_device_uploads/387/387_default.png)
The ZW100 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -81,7 +81,7 @@ Enable/disable wake up for 10 minutes.
## Channels
The following table summarises the channels available for the ZW100
The following table summarises the channels available for the ZW100 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -92,12 +92,11 @@ The following table summarises the channels available for the ZW100
| Sensor (ultraviolet) | sensor_ultraviolet | Temperature | Number |
| Tamper Alarm | alarm_tamper | | Switch |
| Motion Alarm | alarm_motion | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -110,32 +109,31 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (ultraviolet)
Indicates the current ultraviolet level
Indicates the current ultraviolet level.
The ```sensor_ultraviolet``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Tamper Alarm
Indicates if the tamper alarm is triggered
Indicates if the tamper alarm is triggered.
The ```alarm_tamper``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -148,8 +146,7 @@ The following state translation is provided for this channel to the ```Switch```
### Motion Alarm
Indicates if a motion alarm is triggered
Indicates if a motion alarm is triggered.
The ```alarm_motion``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -164,7 +161,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -732,14 +729,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -13,7 +13,7 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![ZW111 product image](https://www.cd-jackson.com/zwave_device_uploads/576/576_default.jpg)
The ZW111 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW111 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -23,7 +23,7 @@ The Nano Dimmer is also a security Z-Wave plus device and supports Over The Air
## Channels
The following table summarises the channels available for the ZW111
The following table summarises the channels available for the ZW111 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -40,7 +40,7 @@ The following table summarises the channels available for the ZW111
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -49,43 +49,41 @@ The ```switch_binary``` channel supports the ```Switch``` item and is in the ```
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (power)
Indicates if a power alarm is triggered
Indicates if a power alarm is triggered.
The ```alarm_power``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -98,8 +96,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -112,8 +109,7 @@ The following state translation is provided for this channel to the ```Switch```
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.

View File

@ -11,6 +11,10 @@ This describes the Z-Wave device *ZW112*, manufactured by *[AEON Labs](http://ae
![ZW112 product image](https://www.cd-jackson.com/zwave_device_uploads/274/274_default.jpg)
The ZW112 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW112 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time.
@ -31,17 +35,16 @@ Press the Action Button once, which will trigger sending out the Wake up notific
## Channels
The following table summarises the channels available for the ZW112
The following table summarises the channels available for the ZW112 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Sensor | sensor_door | Door | Contact |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Door Sensor
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -56,7 +59,7 @@ The following state translation is provided for this channel to the ```Contact``
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -186,14 +189,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -233,9 +236,9 @@ This group supports 5 nodes.
### Documentation Links
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/274/Door-Window-Sensor-6-manual.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/274/Door-Window-Sensor-6-manual.pdf)
* [Z-Wave Certification](https://www.cd-jackson.com/zwave_device_uploads/274/ZC10-16010008.pdf)
* [Aeon Labs Manual](https://www.cd-jackson.com/zwave_device_uploads/274/Door-Window-Sensor-6-manual.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/274/Door-Window-Sensor-6-manual.pdf)
---

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZW116*, manufactured by *[AEON Labs](http://ae
![ZW116 product image](https://www.cd-jackson.com/zwave_device_uploads/591/591_default.jpg)
The ZW116 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW116 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA)
## Channels
The following table summarises the channels available for the ZW116
The following table summarises the channels available for the ZW116 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -37,44 +37,43 @@ The following table summarises the channels available for the ZW116
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (power)
Indicates if a power alarm is triggered
Indicates if a power alarm is triggered.
The ```alarm_power``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -87,8 +86,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -101,8 +99,7 @@ The following state translation is provided for this channel to the ```Switch```
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.

View File

@ -8,7 +8,7 @@ title: ZW117 - ZWave
# ZW117 Range Extender 6
This describes the Z-Wave device *ZW117*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw117_00_000```.
The ZW117 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW117 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the ZW117
The following table summarises the channels available for the ZW117 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -29,7 +29,6 @@ The following table summarises the channels available for the ZW117
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Color Control
@ -37,7 +36,6 @@ The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```
The color channel allows to control the color of a light.
It is also possible to dim values and switch the light on and off.
The ```color_color``` channel supports the ```Color``` item.
### Color Temperature

View File

@ -13,6 +13,10 @@ The device is in the category of *Sensor*, defining Device used to measure somet
![ZW120 product image](https://www.cd-jackson.com/zwave_device_uploads/405/405_default.png)
The ZW120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW120 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
Aeon Labs Door/ Window Sensor Gen5 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time. Its a security Z-Wave device that supports security encryption. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
@ -31,18 +35,17 @@ Remove your Sensor unit from its Back Mounting Plate, press the Action Button on
## Channels
The following table summarises the channels available for the ZW120
The following table summarises the channels available for the ZW120 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Sensor | sensor_door | Door | Contact |
| Alarm (general) | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Door Sensor
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -55,8 +58,7 @@ The following state translation is provided for this channel to the ```Contact``
### Alarm (general)
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -71,7 +73,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -197,14 +199,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -13,7 +13,7 @@ The device is in the category of *Light Bulb*, defining Devices that illuminate
![ZW121 product image](https://www.cd-jackson.com/zwave_device_uploads/639/639_default.jpg)
The ZW121 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW121 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -35,7 +35,7 @@ Note that configuration parameters 37 and 39 only apply when the strip is in col
## Channels
The following table summarises the channels available for the ZW121
The following table summarises the channels available for the ZW121 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -50,12 +50,11 @@ The following table summarises the channels available for the ZW121
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
@ -64,7 +63,6 @@ The ```scene_number``` channel supports the ```Number``` item.
The color channel allows to control the color of a light.
It is also possible to dim values and switch the light on and off.
The ```color_color``` channel supports the ```Color``` item.
### Color Temperature
@ -76,7 +74,7 @@ The ```color_temperature``` channel supports the ```Dimmer``` item and is in the
### Configuration Parameter 37
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,13 +8,22 @@ title: ZW122 - ZWave
# ZW122 Water Sensor 6
This describes the Z-Wave device *ZW122*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw122_00_000```.
The device is in the category of Sensor, defining Device used to measure something.
The device is in the category of *Sensor*, defining Device used to measure something.
# Overview
![ZW122 product image](https://www.cd-jackson.com/zwave_device_uploads/721/721_default.png)
The ZW122 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW122 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/721) to improve the documentation.
## Channels
The following table summarises the channels available for the ZW122
The following table summarises the channels available for the ZW122 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -22,19 +31,19 @@ The following table summarises the channels available for the ZW122
| Alarm (burglar) | alarm_burglar | Door | Switch |
| Alarm (heat) | alarm_heat | | Switch |
| Alarm (flood) | alarm_flood | Door | Switch |
| Battery Level | battery-level | Battery | Number |
| Alarm (flood) 1 | alarm_flood1 | Door | Switch |
| Alarm (flood) 2 | alarm_flood2 | Door | Switch |
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (burglar)
Indicates if the burglar alarm is triggered
Indicates if the burglar alarm is triggered.
The ```alarm_burglar``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -47,8 +56,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -61,8 +69,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (flood)
Indicates if the flood alarm is triggered
Indicates if the flood alarm is triggered.
The ```alarm_flood``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -73,10 +80,15 @@ The following state translation is provided for this channel to the ```Switch```
| OFF | Ok |
| ON | Alarm |
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
### Alarm (flood) 1
Indicates if the flood alarm is triggered
Indicates if the flood alarm is triggered.
The ```alarm_flood1``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -89,8 +101,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (flood) 2
Indicates if the flood alarm is triggered
Indicates if the flood alarm is triggered.
The ```alarm_flood2``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -174,7 +185,12 @@ This group supports 5 nodes.
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |
| COMMAND_CLASS_ALARM_V7| |
### Documentation Links
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/721/Aeon-Labs-Water-Sensor-6-manual.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/721/ES---Water-Sensor-6.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/721).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/721).

View File

@ -13,13 +13,17 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![ZW129 product image](https://www.cd-jackson.com/zwave_device_uploads/390/390_default.jpg)
The ZW129 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW129 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/390) to improve the documentation.
## Channels
The following table summarises the channels available for the ZW129
The following table summarises the channels available for the ZW129 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -33,7 +37,7 @@ The following table summarises the channels available for the ZW129
Delete
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -44,14 +48,13 @@ delete
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Electric meter (watts)
Delete - Device does not have meter channels
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -59,13 +62,13 @@ The ```meter_watts``` channel supports the ```Number``` item and is in the ```En
Delete - Device does not have meter channels
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.

View File

@ -13,6 +13,10 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![ZW130 product image](https://www.cd-jackson.com/zwave_device_uploads/535/535_default.jpg)
The ZW130 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZW130 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
Aeotec WallMote Quad is an intelligent Z-Wave remote controller that mounted on a wall. It has 4 touch buttons that you can easily control the Z-Wave devices in your home network via touching, long pressing or sliding the button areas. Its surface has a RGB LED to indicate the button actions also accompanied by touch beep and vibration. The WallMote Quad is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
@ -45,13 +49,13 @@ Remove your WallMote Quad unit from its Back Mounting Plate, press and hold the
## Channels
The following table summarises the channels available for the ZW130
The following table summarises the channels available for the ZW130 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Scene Number | scene_number | | Number |
| Alarm (power) | alarm_power | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
| Scene Number 1 | scene_number1 | | Number |
| Scene Number 2 | scene_number2 | | Number |
| Scene Number 3 | scene_number3 | | Number |
@ -59,14 +63,13 @@ The following table summarises the channels available for the ZW130
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Alarm (power)
Indicates if a power alarm is triggered
Indicates if a power alarm is triggered.
The ```alarm_power``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -81,29 +84,29 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
### Scene Number 1
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number1``` channel supports the ```Number``` item.
### Scene Number 2
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number2``` channel supports the ```Number``` item.
### Scene Number 3
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number3``` channel supports the ```Number``` item.
### Scene Number 4
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number4``` channel supports the ```Number``` item.
@ -224,14 +227,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -8,13 +8,17 @@ title: ZW132 - ZWave
# ZW132 Dual Nano Switch with Energy Metering
This describes the Z-Wave device *ZW132*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw132_00_000```.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
# Overview
The ZW132 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/724) to improve the documentation.
## Channels
The following table summarises the channels available for the ZW132
The following table summarises the channels available for the ZW132 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -42,44 +46,43 @@ The following table summarises the channels available for the ZW132
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (power)
Indicates if a power alarm is triggered
Indicates if a power alarm is triggered.
The ```alarm_power``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -92,8 +95,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -106,80 +108,79 @@ The following state translation is provided for this channel to the ```Switch```
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Switch 1
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Remove
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 1
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 1
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 1
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Switch 2
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Remove
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 2
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps) 2
Indicates the instantaneous current consumption
Indicates the instantaneous current consumption.
The ```meter_current2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts) 2
Indicates the instantaneous voltage
Indicates the instantaneous voltage.
The ```meter_voltage2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -214,6 +215,7 @@ Detailed information on each parameter can be found in the sections below.
| 122 | Set the control destination for external switch | Set the control destination for external switch |
| 252 | Lock/unlock configuration parameters | Lock/unlock configuration parameters |
| 255 | Reset the Dual Nano Switch | Reset the Dual Nano Switch |
| | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
### Parameter 3: Current Overload Protection.
@ -226,7 +228,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 1 (Enable).
The manufacturer defined default value is ```1``` (Enable).
This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```.
@ -242,7 +244,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```.
@ -259,7 +261,7 @@ The following option values may be configured -:
| 1 | Always on |
| 2 | Always off |
The manufacturer defined default value is 0 (Last status).
The manufacturer defined default value is ```0``` (Last status).
This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```.
@ -277,7 +279,7 @@ The following option values may be configured -:
| 2 | Send Basic CC report |
| 3 | Send Hail CC when using the manual switch |
The manufacturer defined default value is 0 (Send Nothing).
The manufacturer defined default value is ```0``` (Send Nothing).
This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```.
@ -293,7 +295,7 @@ The following option values may be configured -:
| 0 | Send Nothing |
| 1 | Send Basic Set CC |
The manufacturer defined default value is 1 (Send Basic Set CC).
The manufacturer defined default value is ```1``` (Send Basic Set CC).
This parameter has the configuration ID ```config_81_1``` and is of type ```INTEGER```.
@ -309,7 +311,7 @@ The following option values may be configured -:
| 0 | Send Nothing |
| 1 | Send Basic Set CC |
The manufacturer defined default value is 1 (Send Basic Set CC).
The manufacturer defined default value is ```1``` (Send Basic Set CC).
This parameter has the configuration ID ```config_82_1``` and is of type ```INTEGER```.
@ -325,7 +327,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_90_1``` and is of type ```INTEGER```.
@ -336,7 +338,7 @@ Set the threshold value of wattage.
Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25.
The manufacturer defined default value is ```25```.
This parameter has the configuration ID ```config_91_2``` and is of type ```INTEGER```.
@ -347,7 +349,7 @@ Set the threshold value of wattage.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5.
The manufacturer defined default value is ```5```.
This parameter has the configuration ID ```config_92_1``` and is of type ```INTEGER```.
@ -358,7 +360,7 @@ Reset the parameter 101-103
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_100_1_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -385,7 +387,7 @@ The following option values may be configured -:
| 524288 | Send Multi Channel Meter Report of current (A) on Channel 1 |
| 1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 |
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_101_4``` and is of type ```INTEGER```.
@ -411,7 +413,7 @@ The following option values may be configured -:
| 524288 | Send Multi Channel Meter Report of current (A) on Channel 1 |
| 1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 |
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_102_1``` and is of type ```INTEGER```.
@ -437,7 +439,7 @@ The following option values may be configured -:
| 524288 | Send Multi Channel Meter Report of current (A) on Channel 1 |
| 1048576 | Send Multi Channel Meter Report of current (A) on Channel 2 |
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_103_1``` and is of type ```INTEGER```.
@ -448,7 +450,7 @@ Set parameter 111-113 to default value.
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_110_1_wo``` and is of type ```INTEGER```.
This is a write only parameter.
@ -460,7 +462,7 @@ Set the interval of automatic report for Report group 1.
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 10.
The manufacturer defined default value is ```10```.
This parameter has the configuration ID ```config_111_4``` and is of type ```INTEGER```.
@ -471,7 +473,7 @@ Set the interval of automatic report for Report group 2.
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 600.
The manufacturer defined default value is ```600```.
This parameter has the configuration ID ```config_112_4``` and is of type ```INTEGER```.
@ -482,7 +484,7 @@ Set the interval of automatic report for Report group 2.
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 600.
The manufacturer defined default value is ```600```.
This parameter has the configuration ID ```config_113_4``` and is of type ```INTEGER```.
@ -500,7 +502,7 @@ The following option values may be configured -:
| 2 | 3 way switch mode |
| 3 | Momentary push button mode |
The manufacturer defined default value is 0 (Enter automatic identification mode).
The manufacturer defined default value is ```0``` (Enter automatic identification mode).
This parameter has the configuration ID ```config_120_1``` and is of type ```INTEGER```.
@ -518,7 +520,7 @@ The following option values may be configured -:
| 2 | 3 way switch mode |
| 3 | Momentary push button mode |
The manufacturer defined default value is 0 (Enter automatic identification mode).
The manufacturer defined default value is ```0``` (Enter automatic identification mode).
This parameter has the configuration ID ```config_121_1``` and is of type ```INTEGER```.
@ -535,7 +537,7 @@ The following option values may be configured -:
| 2 | control the other nodes |
| 3 | control the output loads of itself and other nodes. |
The manufacturer defined default value is 3 (control the output loads of itself and other nodes.).
The manufacturer defined default value is ```3``` (control the output loads of itself and other nodes.).
This parameter has the configuration ID ```config_122_1``` and is of type ```INTEGER```.
@ -551,7 +553,7 @@ The following option values may be configured -:
| 0 | Unlock |
| 1 | Lock |
The manufacturer defined default value is 0 (Unlock).
The manufacturer defined default value is ```0``` (Unlock).
This parameter has the configuration ID ```config_252_1``` and is of type ```INTEGER```.
@ -566,10 +568,24 @@ The following option values may be configured -:
|--------|-------------|
| 0 | (Default) Reset all configuration parameters |
The manufacturer defined default value is 0 ((Default) Reset all configuration parameters).
The manufacturer defined default value is ```0``` ((Default) Reset all configuration parameters).
This parameter has the configuration ID ```config_255_4``` and is of type ```INTEGER```.
### Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|--------|-------------|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```.
## Association Groups
@ -649,4 +665,4 @@ This group supports 5 nodes.
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/724).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/724).

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZW139*, manufactured by *[AEON Labs](http://ae
![ZW139 product image](https://www.cd-jackson.com/zwave_device_uploads/648/648_default.jpg)
The ZW139 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZW139 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ Once installed behind a switch or socket, Nano Switch offers unparalleled wirele
## Channels
The following table summarises the channels available for the ZW139
The following table summarises the channels available for the ZW139 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,20 +30,19 @@ The following table summarises the channels available for the ZW139
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -56,8 +55,7 @@ The following state translation is provided for this channel to the ```Switch```
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.

View File

@ -8,9 +8,14 @@ title: ZW140 - ZWave
# ZW140 Dual Nano Switch
This describes the Z-Wave device *ZW140*, manufactured by *[AEON Labs](http://aeotec.com/)* with the thing type UID of ```aeon_zw140_00_000```.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
# Overview
![ZW140 product image](https://www.cd-jackson.com/zwave_device_uploads/813/813_default.png)
The ZW140 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
Aeotec Dual Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches.
In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.
@ -19,7 +24,7 @@ The Dual Nano Switch is also a security Z-Wave device and supports Over The Air
## Channels
The following table summarises the channels available for the ZW140
The following table summarises the channels available for the ZW140 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -32,20 +37,19 @@ The following table summarises the channels available for the ZW140
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Alarm (heat)
Indicates if a heat alarm is triggered
Indicates if a heat alarm is triggered.
The ```alarm_heat``` channel supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
@ -58,20 +62,19 @@ The following state translation is provided for this channel to the ```Switch```
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Switch 1
Switch the power on and off
Switch the power on and off.
The ```switch_binary1``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Switch 2
Switch the power on and off
Switch the power on and off.
The ```switch_binary2``` channel supports the ```Switch``` item and is in the ```Switch``` category.
@ -98,6 +101,7 @@ Detailed information on each parameter can be found in the sections below.
| 122 | Set the control destination for external switch | Set the control destination for external switch |
| 252 | Lock/unlock configuration parameters | Lock/unlock configuration parameters |
| 255 | Reset the Dual Nano Switch | Reset the Dual Nano Switch |
| | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
### Parameter 4: Overheat protection.
@ -110,7 +114,7 @@ The following option values may be configured -:
| 0 | Disable |
| 1 | Enable |
The manufacturer defined default value is 0 (Disable).
The manufacturer defined default value is ```0``` (Disable).
This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```.
@ -127,7 +131,7 @@ The following option values may be configured -:
| 1 | Always on |
| 2 | Always off |
The manufacturer defined default value is 0 (Last status).
The manufacturer defined default value is ```0``` (Last status).
This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```.
@ -145,7 +149,7 @@ The following option values may be configured -:
| 2 | Send Basic CC report |
| 3 | Send Hail CC when using the manual switch |
The manufacturer defined default value is 0 (Send Nothing).
The manufacturer defined default value is ```0``` (Send Nothing).
This parameter has the configuration ID ```config_80_1``` and is of type ```INTEGER```.
@ -161,7 +165,7 @@ The following option values may be configured -:
| 0 | Send Nothing |
| 1 | Send Basic Set CC |
The manufacturer defined default value is 1 (Send Basic Set CC).
The manufacturer defined default value is ```1``` (Send Basic Set CC).
This parameter has the configuration ID ```config_81_1``` and is of type ```INTEGER```.
@ -177,7 +181,7 @@ The following option values may be configured -:
| 0 | Send Nothing |
| 1 | Send Basic Set CC |
The manufacturer defined default value is 1 (Send Basic Set CC).
The manufacturer defined default value is ```1``` (Send Basic Set CC).
This parameter has the configuration ID ```config_82_1``` and is of type ```INTEGER```.
@ -194,7 +198,7 @@ The following option values may be configured -:
| 1 | Momentary indicate mode |
| 2 | Night light mode. The LED will remain ON state. |
The manufacturer defined default value is 0 (Energy mode. The LED will follow the status (on/off).).
The manufacturer defined default value is ```0``` (Energy mode. The LED will follow the status (on/off).).
This parameter has the configuration ID ```config_83_1``` and is of type ```INTEGER```.
@ -205,7 +209,7 @@ Set the ON/OFF time of the LED when it is in Night light mode.
0 to 60 The minute time of OFF 256 to 316 The hour time of OFF 65536 to 65596 The minute time of ON 16777216 to 16777276 The hour time of ONThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 16777276 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_84_4``` and is of type ```INTEGER```.
@ -216,7 +220,7 @@ Set appointment 1
256 to 316 The hour value of ON time 16777215 Disable the setting. 0 to 60 The minute value of ON time 65536 to 65543 The day value (Mon to Sun) 16777216 Enable the setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 16777216 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_86_4``` and is of type ```INTEGER```.
@ -227,7 +231,7 @@ Set appointment 2
256 to 316 The hour value of ON time 65536 to 65543 The day value (Mon to Sun) 16777215 Disable the setting. 0 to 60 The minute value of ON time 16777216 Enable the setting.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode.
Values in the range 0 to 16777216 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_87_4``` and is of type ```INTEGER```.
@ -245,7 +249,7 @@ The following option values may be configured -:
| 2 | 3 way switch mode |
| 3 | Momentary push button mode |
The manufacturer defined default value is 0 (Enter automatic identification mode).
The manufacturer defined default value is ```0``` (Enter automatic identification mode).
This parameter has the configuration ID ```config_120_1``` and is of type ```INTEGER```.
@ -263,7 +267,7 @@ The following option values may be configured -:
| 2 | 3 way switch mode |
| 3 | Momentary push button mode |
The manufacturer defined default value is 0 (Enter automatic identification mode).
The manufacturer defined default value is ```0``` (Enter automatic identification mode).
This parameter has the configuration ID ```config_121_1``` and is of type ```INTEGER```.
@ -280,7 +284,7 @@ The following option values may be configured -:
| 2 | control the other nodes |
| 3 | control the output loads of itself and other nodes. |
The manufacturer defined default value is 3 (control the output loads of itself and other nodes.).
The manufacturer defined default value is ```3``` (control the output loads of itself and other nodes.).
This parameter has the configuration ID ```config_122_1``` and is of type ```INTEGER```.
@ -296,7 +300,7 @@ The following option values may be configured -:
| 0 | Unlock |
| 1 | Lock |
The manufacturer defined default value is 0 (Unlock).
The manufacturer defined default value is ```0``` (Unlock).
This parameter has the configuration ID ```config_252_1``` and is of type ```INTEGER```.
@ -312,10 +316,24 @@ The following option values may be configured -:
| 0 | Reset all configuration parameters |
| 1431655765 | Reset to factory default |
The manufacturer defined default value is 0 (Reset all configuration parameters).
The manufacturer defined default value is ```0``` (Reset all configuration parameters).
This parameter has the configuration ID ```config_255_4``` and is of type ```INTEGER```.
### Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|--------|-------------|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```.
## Association Groups
@ -391,7 +409,11 @@ This group supports 5 nodes.
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |
### Documentation Links
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/813/Dual-Nano-Switch-manual.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/813).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/813).

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *ZDS-UD10*, manufactured by *Airline Mechanical
![ZDS-UD10 product image](https://www.cd-jackson.com/zwave_device_uploads/184/184_default.png)
The ZDS-UD10 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The ZDS-UD10 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the ZDS-UD10
The following table summarises the channels available for the ZDS-UD10 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,7 +30,6 @@ The following table summarises the channels available for the ZDS-UD10
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
@ -62,7 +61,7 @@ The device does not support associations.
### Documentation Links
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/184/ZDS-manual.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/184/ZDS-manual.pdf)
---

View File

@ -8,39 +8,44 @@ title: ASL-03 - ZWave
# ASL-03 August Smart Lock Pro 3rd Gen
This describes the Z-Wave device *ASL-03*, manufactured by *August Smart Locks* with the thing type UID of ```august_asl03_00_000```.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The device is in the category of *Lock*, defining Devices whose primary pupose is locking something.
# Overview
![ASL-03 product image](https://www.cd-jackson.com/zwave_device_uploads/743/743_default.png)
The ASL-03 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
## Overview
Give your customer total control over their front door, from anywhere. The August Smart Lock Pro is the leading Z-Wave Plus retrofit smart lock. You can lock and unlock your door, create virtual keys for guests, and keep track of who comes and goes with a 24/7 activity log, all from your iOS or Android smartphone. The August Smart Lock Pro features Z-Wave Plus and BLE and it is the only lock to support the three leading voice-assistants, Siri, Google Assistant, and Amazon Alexa. The lock quickly installs on the inside of your door with just a screwdriver. Keep your exterior door hardware exactly as it is and use your traditional key any time.
## Inclusion Information
### Inclusion Information
In order to include the August Smart Lock on to a Z-Wave network the user will have to do the following:
1. Open the August app 2. Go to the Lock Settings screen 3. Select Z-Wave Settings 4. Select Add To A Z-Wave Network 5. Put the controller into inclusion mode and select My Hub is in Inclusion Mode on the August app
## Exclusion Information
### Exclusion Information
In order to exclude the August Smart Lock from a Z-Wave network the user will have to do the following:
1. Open the August app 2. Go to the Lock Settings screen 3. Select Z-Wave Settings 4. Select Remove Z-Wave Device 5. Put the controller into exclusion mode and select My Hub is in Exlusion Mode on the August app
## Wakeup Information
### Wakeup Information
Any operation (manual, RF, etc.) will wake up the lock.
## Channels
The following table summarises the channels available for the ASL-03
The following table summarises the channels available for the ASL-03 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Lock | sensor_door | Door | Contact |
| Alarm (access) | alarm_entry | Door | Switch |
| Battery Level | battery-level | Battery | Number |
### Door Lock
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -53,8 +58,7 @@ The following state translation is provided for this channel to the ```Contact``
### Alarm (access)
Indicates if the entry alarm is triggered
Indicates if the entry alarm is triggered.
The ```alarm_entry``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -65,6 +69,12 @@ The following state translation is provided for this channel to the ```Switch```
| ON | Open |
| OFF | Closed |
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
## Device Configuration
@ -109,7 +119,12 @@ This group supports 5 nodes.
| COMMAND_CLASS_VERSION_V2| |
| COMMAND_CLASS_SECURITY_V1| |
### Documentation Links
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/743/August-Z-Wave-Required-Documentation.pdf)
* [August Smart Lock Pro 3rd Gen Image](https://www.cd-jackson.com/zwave_device_uploads/743/August-Smart-Lock-Propng.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/743).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/743).

View File

@ -8,9 +8,14 @@ title: BSL01 - ZWave
# BSL01
This describes the Z-Wave device *BSL01*, manufactured by *[Benetek](http://www.benetek.co.nz)* with the thing type UID of ```benetek_bsl01_00_000```.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The device is in the category of *Lock*, defining Devices whose primary pupose is locking something.
# Overview
![BSL01 product image](https://www.cd-jackson.com/zwave_device_uploads/828/828_default.png)
The BSL01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
## Overview
BENETEK smart lock is night lock style with dead bolt, remote, key, RF card, keypad, Z-Wave.
@ -26,13 +31,13 @@ Features of the Latch: Lock Latch length > 25mm, Comply with GA/T73-94 5.16B sta
Smart Hidden Door Lock restores factory default automatically when the device is excluded. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
## Inclusion Information
### Inclusion Information
1. Ensure the SHDL is powered and the battery is fully charged.
2. Set the main controller into the Add device mode (see a main controllers operating manual).
3. Triple click Z-Wave button on the Z-Wave module(inside lock body) within 1.5 seconds, the LED will flicker rapidly while inclusion process implement and light on 2 second after processing complete.
## Exclusion Information
### Exclusion Information
1. Ensure the SHDL is powered and the battery is fully charged.
2. Set the main controller into the Remove device mode (see a main controllers operating manual).
@ -40,18 +45,25 @@ Smart Hidden Door Lock restores factory default automatically when the device is
## Channels
The following table summarises the channels available for the BSL01
The following table summarises the channels available for the BSL01 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Lock | lock_door | Door | Switch |
| Battery Level | battery-level | Battery | Number |
### Door Lock
Lock and unlock the door
Lock and unlock the door.
The ```lock_door``` channel supports the ```Switch``` item and is in the ```Door``` category.
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
## Device Configuration
@ -105,7 +117,11 @@ This group supports 1 nodes.
| COMMAND_CLASS_VERSION_V2| |
| COMMAND_CLASS_SECURITY_V1| |
### Documentation Links
* [Benetek Smart Lock User Manual](https://www.cd-jackson.com/zwave_device_uploads/828/BENETEK-SL-EN-V4-Ed-5.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/828).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/828).

View File

@ -13,7 +13,7 @@ The device is in the category of *Siren*, defining Siren used by Alarm systems.
![Alarm Sound product image](https://www.cd-jackson.com/zwave_device_uploads/443/443_default.png)
The Alarm Sound does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The Alarm Sound supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the Alarm Sound
The following table summarises the channels available for the Alarm Sound -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -30,14 +30,13 @@ The following table summarises the channels available for the Alarm Sound
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *builtInDimmer*, manufactured by *[BeNext](http
![builtInDimmer product image](https://www.cd-jackson.com/zwave_device_uploads/225/225_default.png)
The builtInDimmer does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The builtInDimmer supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the builtInDimmer
The following table summarises the channels available for the builtInDimmer -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -32,18 +32,17 @@ The following table summarises the channels available for the builtInDimmer
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -11,25 +11,28 @@ This describes the Z-Wave device *doorSensor*, manufactured by *[BeNext](http://
![doorSensor product image](https://www.cd-jackson.com/zwave_device_uploads/223/223_default.png)
The doorSensor supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The doorSensor does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/223) to improve the documentation.
## Channels
The following table summarises the channels available for the doorSensor
The following table summarises the channels available for the doorSensor -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Door Sensor | sensor_door | Door | Contact |
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Alarm (CO) | alarm_co | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Door Sensor
Indicates if the door/window is open or closed
Indicates if the door/window is open or closed.
The ```sensor_door``` channel supports the ```Contact``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -42,14 +45,13 @@ The following state translation is provided for this channel to the ```Contact``
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (CO)
Indicates if the carbon monoxide alarm is triggered
Indicates if the carbon monoxide alarm is triggered.
The ```alarm_co``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -64,7 +66,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -144,14 +146,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -11,13 +11,15 @@ This describes the Z-Wave device *Energy Switch +*, manufactured by *[BeNext](ht
![Energy Switch + product image](https://www.cd-jackson.com/zwave_device_uploads/445/445_default.png)
The Energy Switch + does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/445) to improve the documentation.
## Channels
The following table summarises the channels available for the Energy Switch +
The following table summarises the channels available for the Energy Switch + -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,19 +29,19 @@ The following table summarises the channels available for the Energy Switch +
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *Heating Control*, manufactured by *[BeNext](ht
![Heating Control product image](https://www.cd-jackson.com/zwave_device_uploads/473/473_default.png)
The Heating Control does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The Heating Control supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -23,7 +23,7 @@ Note: This product only works if the current communication between your thermost
## Channels
The following table summarises the channels available for the Heating Control
The following table summarises the channels available for the Heating Control -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -37,7 +37,7 @@ The following table summarises the channels available for the Heating Control
Room temperature of the room thermostat
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
@ -45,7 +45,7 @@ The ```sensor_temperature``` channel supports the ```Number``` item and is in th
The temperature outside, if reported by the boiler
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
@ -53,8 +53,7 @@ The ```sensor_temperature``` channel supports the ```Number``` item and is in th
Determines the mode of the thermostat, either ON ("Heat", 1), or OFF ("Off", 0). The heating setpoint will be applied if the mode Heat is applied and the Energy saving setpoint if the mode Off is applied
Sets the thermostat
Sets the thermostat.
The ```thermostat_mode``` channel supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -82,7 +81,7 @@ The following state translation is provided for this channel to the ```Number```
The setpoint used for the heating schedule
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
@ -90,7 +89,7 @@ The ```thermostat_setpoint``` channel supports the ```Number``` item and is in t
The setpoint used for the energy save heating program
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.

View File

@ -11,13 +11,17 @@ This describes the Z-Wave device *Molite*, manufactured by *[BeNext](http://www.
![Molite product image](https://www.cd-jackson.com/zwave_device_uploads/374/374_default.png)
The Molite supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Molite does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/374) to improve the documentation.
## Channels
The following table summarises the channels available for the Molite
The following table summarises the channels available for the Molite -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -25,12 +29,11 @@ The following table summarises the channels available for the Molite
| Sensor (luminance) | sensor_luminance | Temperature | Number |
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -43,20 +46,19 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -71,7 +73,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -290,14 +292,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *P1-dongle*, manufactured by *[BeNext](http://w
![P1-dongle product image](https://www.cd-jackson.com/zwave_device_uploads/340/340_default.png)
The P1-dongle does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The P1-dongle supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -44,7 +44,7 @@ Use the button to switch the P1 Dongle to Inclusion (LED pulse twice per second)
## Channels
The following table summarises the channels available for the P1-dongle
The following table summarises the channels available for the P1-dongle -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -58,43 +58,43 @@ The following table summarises the channels available for the P1-dongle
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 1
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 1
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts1``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh) 2
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts) 2
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts2``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Gas meter (G_Cubic_Meters) 3
Indicates the gas use in cubic meters
Indicates the gas use in cubic meters.
The ```meter_gas_cubic_meters3``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *plugInDimmer*, manufactured by *[BeNext](http:
![plugInDimmer product image](https://www.cd-jackson.com/zwave_device_uploads/226/226_default.png)
The plugInDimmer does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The plugInDimmer supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the plugInDimmer
The following table summarises the channels available for the plugInDimmer -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -32,18 +32,17 @@ The following table summarises the channels available for the plugInDimmer
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,7 +8,7 @@ title: powerSwitch - ZWave
# powerSwitch Power Switch EU
This describes the Z-Wave device *powerSwitch*, manufactured by *[BeNext](http://www.benext.eu/)* with the thing type UID of ```benext_powerswitch_00_000```.
The powerSwitch does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The powerSwitch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the powerSwitch
The following table summarises the channels available for the powerSwitch -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -24,7 +24,7 @@ The following table summarises the channels available for the powerSwitch
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.

View File

@ -11,31 +11,34 @@ This describes the Z-Wave device *Tag Reader*, manufactured by *[BeNext](http://
![Tag Reader product image](https://www.cd-jackson.com/zwave_device_uploads/444/444_default.png)
The Tag Reader supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Tag Reader does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/444) to improve the documentation.
## Channels
The following table summarises the channels available for the Tag Reader
The following table summarises the channels available for the Tag Reader -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Switch | switch_binary | Switch | Switch |
| Alarm (burglar) | alarm_burglar | Door | Switch |
| Alarm (access) | notification_access_control | | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Alarm (burglar)
Indicates if the burglar alarm is triggered
Indicates if the burglar alarm is triggered.
The ```alarm_burglar``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -52,7 +55,7 @@ Event ID 5 = Away
Event ID 6 = Home
Access Control
Access Control.
The ```notification_access_control``` channel supports the ```Number``` item. This is a read only channel so will only be updated following state changes from the device.
@ -102,7 +105,7 @@ The following state translation is provided for this channel to the ```Number```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -205,14 +208,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -8,13 +8,17 @@ title: POPE005206 - ZWave
# POPE005206 Z Weather
This describes the Z-Wave device *POPE005206*, manufactured by *Bönig und Kallenbach oHG* with the thing type UID of ```bonig_pope005206_00_000```.
The POPE005206 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The POPE005206 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/234) to improve the documentation.
## Channels
The following table summarises the channels available for the POPE005206
The following table summarises the channels available for the POPE005206 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,12 +31,11 @@ The following table summarises the channels available for the POPE005206
| Sensor (barometric pressure) | sensor_barpressure | Temperature | Number |
| Electric meter (kWh) | meter_kwh | Energy | Number |
| Electric meter (pulses) | meter_pulse | Energy | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -45,49 +48,49 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (dew point)
Indicates the dewpoint
Indicates the dewpoint.
The ```sensor_dewpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (relative humidity)
Indicates the current relative humidity
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (velocity)
Indicates the current velocity
Indicates the current velocity.
The ```sensor_velocity``` channel supports the ```Number``` item. This is a read only channel so will only be updated following state changes from the device.
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (barometric pressure)
Indicates the barometric pressure
Indicates the barometric pressure.
The ```sensor_barpressure``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (pulses)
Indicates the pulse count
Indicates the pulse count.
The ```meter_pulse``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
@ -95,7 +98,7 @@ The ```meter_pulse``` channel supports the ```Number``` item and is in the ```En
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -140,14 +143,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -8,24 +8,27 @@ title: ZCOMBO - ZWave
# ZCOMBO Smoke and Carbon Monoxide Alarm
This describes the Z-Wave device *ZCOMBO*, manufactured by *BRK Brands, Inc.* with the thing type UID of ```brk_zcombo_00_000```.
The ZCOMBO supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZCOMBO does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/238) to improve the documentation.
## Channels
The following table summarises the channels available for the ZCOMBO
The following table summarises the channels available for the ZCOMBO -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Heartbeat | alarm_general | Door | Switch |
| Smoke | alarm_smoke | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Heartbeat
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -38,8 +41,7 @@ The following state translation is provided for this channel to the ```Switch```
### Smoke
Indicates if a smoke is triggered
Indicates if a smoke is triggered.
The ```alarm_smoke``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -54,7 +56,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -113,7 +115,7 @@ This group supports 1 nodes.
### Documentation Links
* [User](https://www.cd-jackson.com/zwave_device_uploads/238/NXZCOMBO-Specifications.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/238/NXZCOMBO-Specifications.pdf)
* [Instructions sheet](https://www.cd-jackson.com/zwave_device_uploads/238/first-alert-NXZCOMBO-instructions.pdf)
---

View File

@ -10,23 +10,26 @@ This describes the Z-Wave device *ZSMOKE*, manufactured by *BRK Brands, Inc.* wi
The device is in the category of *Smoke Detector*, defining Smoke detectors.
The ZSMOKE supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZSMOKE does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/239) to improve the documentation.
## Channels
The following table summarises the channels available for the ZSMOKE
The following table summarises the channels available for the ZSMOKE -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -41,7 +44,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.

View File

@ -8,7 +8,7 @@ title: SW-ZCS-1 - ZWave
# SW-ZCS-1 Cord Switch
This describes the Z-Wave device *SW-ZCS-1*, manufactured by *CBCC Domotique SAS* with the thing type UID of ```cbcc_swzcs1_00_000```.
The SW-ZCS-1 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The SW-ZCS-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the SW-ZCS-1
The following table summarises the channels available for the SW-ZCS-1 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -24,7 +24,7 @@ The following table summarises the channels available for the SW-ZCS-1
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.

View File

@ -8,24 +8,27 @@ title: HSM02 - ZWave
# HSM02 Door Window Sensor
This describes the Z-Wave device *HSM02*, manufactured by *[Chromagic Technologies Corporation](http://www.ctc-chromagic.com/)* with the thing type UID of ```chromagic_hsm02_00_000```.
The HSM02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The HSM02 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/342) to improve the documentation.
## Channels
The following table summarises the channels available for the HSM02
The following table summarises the channels available for the HSM02 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Binary Sensor | sensor_binary | Door | Switch |
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -38,8 +41,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -54,7 +56,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -99,14 +101,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -11,24 +11,27 @@ This describes the Z-Wave device *SM103*, manufactured by *[Chromagic Technologi
![SM103 product image](https://www.cd-jackson.com/zwave_device_uploads/428/428_default.png)
The SM103 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The SM103 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/428) to improve the documentation.
## Channels
The following table summarises the channels available for the SM103
The following table summarises the channels available for the SM103 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Binary Sensor | sensor_binary | Door | Switch |
| Alarm | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -41,8 +44,7 @@ The following state translation is provided for this channel to the ```Switch```
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -57,7 +59,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -102,14 +104,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -11,25 +11,28 @@ This describes the Z-Wave device *A803N*, manufactured by *Cloud Media* with the
![A803N product image](https://www.cd-jackson.com/zwave_device_uploads/521/521_default.png)
The A803N supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The A803N does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/521) to improve the documentation.
## Channels
The following table summarises the channels available for the A803N
The following table summarises the channels available for the A803N -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Binary Sensor | sensor_binary | Door | Switch |
| Sensor (luminance) | sensor_luminance | Temperature | Number |
| Alarm (general) | alarm_general | Door | Switch |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Binary Sensor
Indicates if a sensor has triggered
Indicates if a sensor has triggered.
The ```sensor_binary``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -42,14 +45,13 @@ The following state translation is provided for this channel to the ```Switch```
### Sensor (luminance)
Indicates the current light reading
Indicates the current light reading.
The ```sensor_luminance``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (general)
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -64,7 +66,7 @@ The following state translation is provided for this channel to the ```Switch```
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -229,14 +231,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups

View File

@ -11,7 +11,7 @@ This describes the Z-Wave device *CH-201*, manufactured by *ConnectHome* with th
![CH-201 product image](https://www.cd-jackson.com/zwave_device_uploads/582/582_default.jpg)
The CH-201 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The CH-201 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -19,7 +19,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the CH-201
The following table summarises the channels available for the CH-201 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -35,14 +35,13 @@ The following table summarises the channels available for the CH-201
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Thermostat mode
Sets the thermostat
Sets the thermostat.
The ```thermostat_mode``` channel supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -68,8 +67,7 @@ The following state translation is provided for this channel to the ```Number```
### Operating State
Sets the thermostat operating state
Sets the thermostat operating state.
The ```thermostat_state``` channel supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -86,20 +84,19 @@ The following state translation is provided for this channel to the ```Number```
### Setpoint (heating)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Sensor (temperature) 1
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature1``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Thermostat mode 1
Sets the thermostat
Sets the thermostat.
The ```thermostat_mode1``` channel supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -125,8 +122,7 @@ The following state translation is provided for this channel to the ```Number```
### Operating State 1
Sets the thermostat operating state
Sets the thermostat operating state.
The ```thermostat_state1``` channel supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -143,13 +139,13 @@ The following state translation is provided for this channel to the ```Number```
### Setpoint (heating) 1
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint1``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Sensor (temperature) 2
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature2``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -10,13 +10,17 @@ This describes the Z-Wave device *RF9500*, manufactured by *Cooper Wiring Device
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The RF9500 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The RF9500 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/14) to improve the documentation.
## Channels
The following table summarises the channels available for the RF9500
The following table summarises the channels available for the RF9500 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -27,7 +31,6 @@ The following table summarises the channels available for the RF9500
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
@ -67,7 +70,7 @@ This group supports 5 nodes.
### Documentation Links
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/14/c57bf0c8-b86d-4b6c-bb23-706ee28885ad.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/14/c57bf0c8-b86d-4b6c-bb23-706ee28885ad.pdf)
---

View File

@ -13,7 +13,7 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![RF9501 product image](https://www.cd-jackson.com/zwave_device_uploads/18/18_default.jpg)
The RF9501 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The RF9501 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the RF9501
The following table summarises the channels available for the RF9501 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -31,20 +31,19 @@ The following table summarises the channels available for the RF9501
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,7 +8,7 @@ title: RF9517 - ZWave
# RF9517 Accessory Switch
This describes the Z-Wave device *RF9517*, manufactured by *Cooper Wiring Devices* with the thing type UID of ```cooper_rf9517_00_000```.
The RF9517 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The RF9517 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -24,7 +24,7 @@ initiate exclusion mode on controller device press the RF9517 button once RF9517
## Channels
The following table summarises the channels available for the RF9517
The following table summarises the channels available for the RF9517 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -33,13 +33,13 @@ The following table summarises the channels available for the RF9517
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.

View File

@ -13,7 +13,7 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![RF9534 product image](https://www.cd-jackson.com/zwave_device_uploads/467/467_default.jpg)
The RF9534 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The RF9534 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the RF9534
The following table summarises the channels available for the RF9534 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -34,19 +34,17 @@ The following table summarises the channels available for the RF9534
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,13 +8,17 @@ title: RF9536-N - ZWave
# RF9536-N 1000W Dimmer Light Switch
This describes the Z-Wave device *RF9536-N*, manufactured by *Cooper Wiring Devices* with the thing type UID of ```cooper_rf9536n_00_000```.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
# Overview
The RF9536-N supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/780) to improve the documentation.
## Channels
The following table summarises the channels available for the RF9536-N
The following table summarises the channels available for the RF9536-N -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -29,25 +33,23 @@ The following table summarises the channels available for the RF9536-N
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Dimmer Ramp Time
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -60,8 +62,7 @@ The following state translation is provided for this channel to the ```Switch```
### Local Device Protection
Sets the local protection mode
Sets the local protection mode.
The ```protection_local``` channel supports the ```Number``` item.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -91,6 +92,7 @@ Detailed information on each parameter can be found in the sections below.
| 8 | Kickstart / Rapid Start | Turn on or off rapid start feature |
| 11 | Minimum Dimmer Level | The minimum dim level the switch will allow |
| 12 | Maximum Dimmer Level | The maximum dim level the switch will allow |
| | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
### Parameter 1: Delayed OFF time
@ -98,7 +100,7 @@ time in seconds to delay OFF
The amount of time in seconds the switch will delay when trigger the delayed off feature
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```.
@ -109,7 +111,7 @@ Time in seconds for panic mode ON
The amount of time in seconds the switch will turn on for when panic mode is triggered
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```.
@ -120,7 +122,7 @@ time in seconds for OFF in panic mode
The amount of time in seconds the switch will turn off for when panic mode is triggered
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```.
@ -131,7 +133,7 @@ Send value to association group on trigger
Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```.
@ -148,7 +150,7 @@ The following option values may be configured -:
| 2 | ON |
| 3 | Last State |
The manufacturer defined default value is 1 (OFF).
The manufacturer defined default value is ```1``` (OFF).
This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```.
@ -164,7 +166,7 @@ The following option values may be configured -:
| 1 | OFF |
| 2 | ON |
The manufacturer defined default value is 1 (OFF).
The manufacturer defined default value is ```1``` (OFF).
This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```.
@ -175,7 +177,7 @@ Time in seconds to reach desired level
The amount of time in seconds the switch will take to reach the desired dim level
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```.
@ -191,7 +193,7 @@ The following option values may be configured -:
| 1 | OFF |
| 2 | ON |
The manufacturer defined default value is 1 (OFF).
The manufacturer defined default value is ```1``` (OFF).
This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```.
@ -202,7 +204,7 @@ The minimum dim level the switch will allow
Values in the range 4 to 99 may be set.
The manufacturer defined default value is 4.
The manufacturer defined default value is ```4```.
This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```.
@ -213,10 +215,24 @@ The maximum dim level the switch will allow
Values in the range 4 to 99 may be set.
The manufacturer defined default value is 99.
The manufacturer defined default value is ```99```.
This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```.
### Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|--------|-------------|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```.
## Association Groups
@ -262,4 +278,4 @@ This group supports 1 nodes.
---
Did you spot an error in the above definition or want to improve the content?
You can [edit the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/780).
You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/780).

View File

@ -13,7 +13,7 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![RF9540-N product image](https://www.cd-jackson.com/zwave_device_uploads/16/16_default.jpg)
The RF9540-N does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The RF9540-N supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the RF9540-N
The following table summarises the channels available for the RF9540-N -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -37,25 +37,23 @@ The following table summarises the channels available for the RF9540-N
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Dimmer Ramp Time
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -68,8 +66,7 @@ The following state translation is provided for this channel to the ```Switch```
### Local Device Protection
Sets the local protection mode
Sets the local protection mode.
The ```protection_local``` channel supports the ```Number``` item.
The following state translation is provided for this channel to the ```Number``` item type -:

View File

@ -13,7 +13,7 @@ The device is in the category of *Wall Switch*, defining Any device attached to
![RF9542 product image](https://www.cd-jackson.com/zwave_device_uploads/17/17_default.jpg)
The RF9542 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The RF9542 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -21,7 +21,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the RF9542
The following table summarises the channels available for the RF9542 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -36,25 +36,23 @@ The following table summarises the channels available for the RF9542
The brightness channel allows to control the brightness of a light.
It is also possible to switch the light on and off.
The ```switch_dimmer``` channel supports the ```Dimmer``` item and is in the ```DimmableLight``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
### Dimmer Ramp Time
Generic class for configuration parameter
Generic class for configuration parameter.
The ```config_decimal``` channel supports the ```Decimal``` item.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.
@ -67,8 +65,7 @@ The following state translation is provided for this channel to the ```Switch```
### Local Device Protection
Sets the local protection mode
Sets the local protection mode.
The ```protection_local``` channel supports the ```Number``` item.
The following state translation is provided for this channel to the ```Number``` item type -:
@ -237,7 +234,7 @@ This group supports 5 nodes.
### Documentation Links
* [Z-Wave Certification](https://www.cd-jackson.com/zwave_device_uploads/17/ZC07080006.pdf)
* [Engineering Spec](https://www.cd-jackson.com/zwave_device_uploads/17/AspireRFSmartDimmerSystemAccessorySpecSheet.pdf)
* [Engineering Specification](https://www.cd-jackson.com/zwave_device_uploads/17/AspireRFSmartDimmerSystemAccessorySpecSheet.pdf)
---

View File

@ -8,7 +8,7 @@ title: RFTR9505 - ZWave
# RFTR9505 Duplex receptical
This describes the Z-Wave device *RFTR9505*, manufactured by *Cooper Wiring Devices* with the thing type UID of ```cooper_rftr9505_00_000```.
The RFTR9505 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The RFTR9505 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.
## Overview
@ -16,7 +16,7 @@ No device information is provided in the database. Consider [updating the databa
## Channels
The following table summarises the channels available for the RFTR9505
The following table summarises the channels available for the RFTR9505 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -25,14 +25,13 @@ The following table summarises the channels available for the RFTR9505
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Alarm
Indicates if an alarm is triggered
Indicates if an alarm is triggered.
The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -8,15 +8,13 @@ title: RFWC5 - ZWave
# RFWC5 5-Scene Keypad
This describes the Z-Wave device *RFWC5*, manufactured by *Cooper Wiring Devices* with the thing type UID of ```cooper_rfwc5_00_000```.
The RFWC5 does not permanently listening for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/15) to improve the documentation.
## Channels
The following table summarises the channels available for the RFWC5
The following table summarises the channels available for the RFWC5 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -24,7 +22,7 @@ The following table summarises the channels available for the RFWC5
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.

View File

@ -10,13 +10,15 @@ This describes the Z-Wave device *PSMZ0001*, manufactured by *Coqon* with the th
The device is in the category of *Power Outlet*, defining Small devices to be plugged into a power socket in a wall which stick there.
The PSMZ0001 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/427) to improve the documentation.
## Channels
The following table summarises the channels available for the PSMZ0001
The following table summarises the channels available for the PSMZ0001 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -26,19 +28,19 @@ The following table summarises the channels available for the PSMZ0001
### Switch
Switch the power on and off
Switch the power on and off.
The ```switch_binary``` channel supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (watts)
Indicates the instantaneous power consumption
Indicates the instantaneous power consumption.
The ```meter_watts``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.

View File

@ -11,6 +11,10 @@ This describes the Z-Wave device *010101*, manufactured by *Danfoss* with the th
![010101 product image](https://www.cd-jackson.com/zwave_device_uploads/449/449_default.jpg)
The 010101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The 010101 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
### Inclusion Information
@ -23,24 +27,24 @@ Short push middle button
## Channels
The following table summarises the channels available for the 010101
The following table summarises the channels available for the 010101 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Setpoint (heating) | thermostat_setpoint | Temperature | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
| Clock Time Offset | time_offset | Temperature | Number |
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Setpoint (heating)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
@ -48,12 +52,11 @@ The ```thermostat_setpoint``` channel supports the ```Number``` item and is in t
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.
@ -97,7 +100,7 @@ This group supports 1 nodes.
### Documentation Links
* [manual](https://www.cd-jackson.com/zwave_device_uploads/449/Manual-Thermostat-POPP-en.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/449/Manual-Thermostat-POPP-en.pdf)
---

View File

@ -11,6 +11,10 @@ This describes the Z-Wave device *014G0160*, manufactured by *Danfoss* with the
![014G0160 product image](https://www.cd-jackson.com/zwave_device_uploads/359/359_default.png)
The 014G0160 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The 014G0160 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
### Inclusion Information
@ -27,30 +31,30 @@ Any button (LED, Temp+ or Temp-)
## Channels
The following table summarises the channels available for the 014G0160
The following table summarises the channels available for the 014G0160 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Setpoint (heating) | thermostat_setpoint | Temperature | Number |
| Setpoint (cooling) | thermostat_setpoint | Temperature | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Setpoint (heating)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Setpoint (cooling)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
@ -58,7 +62,7 @@ The ```thermostat_setpoint``` channel supports the ```Number``` item and is in t
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -232,14 +236,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -270,7 +274,7 @@ The device does not support associations.
### Documentation Links
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/359/danfoss-014g0160-m.pdf)
* [Danfoss 014G0160 with CommandClasses, Functions and Configuration](https://www.cd-jackson.com/zwave_device_uploads/359/Danfoss-014G0160.pdf)
* [CommandClasses, Functions and Configuration](https://www.cd-jackson.com/zwave_device_uploads/359/Danfoss-014G0160.pdf)
---

View File

@ -11,13 +11,17 @@ This describes the Z-Wave device *DTHERMZ5*, manufactured by *Danfoss* with the
![DTHERMZ5 product image](https://www.cd-jackson.com/zwave_device_uploads/501/501_default.jpg)
The DTHERMZ5 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DTHERMZ5 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/501) to improve the documentation.
## Channels
The following table summarises the channels available for the DTHERMZ5
The following table summarises the channels available for the DTHERMZ5 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
@ -25,29 +29,29 @@ The following table summarises the channels available for the DTHERMZ5
| Setpoint (cooling) | thermostat_setpoint | Temperature | Number |
| Setpoint (heating) | thermostat_setpoint | Temperature | Number |
| Scene Number | scene_number | | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Setpoint (cooling)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Setpoint (heating)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
### Scene Number
Triggers when a scene button is pressed
Triggers when a scene button is pressed.
The ```scene_number``` channel supports the ```Number``` item.
@ -55,7 +59,7 @@ The ```scene_number``` channel supports the ```Number``` item.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
@ -229,14 +233,14 @@ This setting is defined in *seconds*. It is advisable not to set this interval t
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
### Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address.
In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID ```wakeup_interval``` and is of type ```INTEGER```.
This parameter has the configuration ID ```wakeup_node``` and is of type ```INTEGER```.
## Association Groups
@ -269,7 +273,7 @@ The device does not support associations.
### Documentation Links
* [Manual](https://www.cd-jackson.com/zwave_device_uploads/501/Bedienungsanleitung-DTHERMZ5.pdf)
* [User Manual](https://www.cd-jackson.com/zwave_device_uploads/501/Bedienungsanleitung-DTHERMZ5.pdf)
---

View File

@ -11,30 +11,34 @@ This describes the Z-Wave device *DTHERMZ6*, manufactured by *Danfoss* with the
![DTHERMZ6 product image](https://www.cd-jackson.com/zwave_device_uploads/502/502_default.jpg)
The DTHERMZ6 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The DTHERMZ6 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
## Overview
No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/502) to improve the documentation.
## Channels
The following table summarises the channels available for the DTHERMZ6
The following table summarises the channels available for the DTHERMZ6 -:
| Channel | Channel Id | Category | Item Type |
|---------|------------|----------|-----------|
| Sensor (temperature) | sensor_temperature | Temperature | Number |
| Setpoint (heating) | thermostat_setpoint | Temperature | Number |
| battery-level | system.battery-level | Battery | Number |
| Battery Level | battery-level | Battery | Number |
| Clock Time Offset | time_offset | Temperature | Number |
### Sensor (temperature)
Indicates the current temperature
Indicates the current temperature.
The ```sensor_temperature``` channel supports the ```Number``` item and is in the ```Temperature``` category. This is a read only channel so will only be updated following state changes from the device.
### Setpoint (heating)
Sets the thermostate setpoint
Sets the thermostate setpoint.
The ```thermostat_setpoint``` channel supports the ```Number``` item and is in the ```Temperature``` category.
@ -42,12 +46,11 @@ The ```thermostat_setpoint``` channel supports the ```Number``` item and is in t
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category.
### Clock Time Offset
Provides the current time difference for the devices time
Provides the current time difference for the devices time.
The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category.

Some files were not shown because too many files have changed in this diff Show More