Updated external content (Jenkins build 1415)
parent
861439e766
commit
27d8a3a51a
|
@ -24,6 +24,18 @@ The KNX binding then can communicate directly with this gateway.
|
|||
Alternatively, a PC running [KNXD](https://github.com/knxd/knxd) (free open source component software) can be put in between which then acts as a broker allowing multiple client to connect to the same gateway.
|
||||
Since the protocol is identical, the KNX binding can also communicate with it transparently.
|
||||
|
||||
***Attention:*** With the introduction of Unit of Measurement (UoM) support, some data types have changed (see `number` channel below):
|
||||
|
||||
- Data type for DPT 5.001 (Percent 8bit, 0 -> 100%) has changed from `PercentType` to `QuantityType`for `number` channels (`dimmer`, `color`, `rollershutter` channels stay with `PercentType`).
|
||||
- Data type for DPT 5.004 (Percent 8bit, 0 -> 255%) has changed from `PercentType` to `QuantityType`.
|
||||
- Data type for DPT 6.001 (Percent 8bit -128 -> 127%) has changed from `PercentType` to `QuantityType`.
|
||||
- Data type for DPT 9.007 (Humidity) has changed from `PercentType` to `QuantityType`.
|
||||
|
||||
Rules that check for or compare states and transformations that expect a raw value might need adjustments.
|
||||
If you run into trouble with that and need some time, you can disable UoM support on binding level via the `disableUoM` parameter.
|
||||
UoM are enabled by default and need to be disabled manually.
|
||||
A new setting is activated immediately without restart.
|
||||
|
||||
## Supported Things
|
||||
|
||||
The KNX binding supports two types of bridges, and one type of things to access the KNX bus.
|
||||
|
@ -31,7 +43,8 @@ There is an _ip_ bridge to connect to KNX IP Gateways, and a _serial_ bridge for
|
|||
|
||||
## Bridges
|
||||
|
||||
The following two bridge types are supported. Bridges don't have channels on their own.
|
||||
The following two bridge types are supported.
|
||||
Bridges don't have channels on their own.
|
||||
|
||||
### IP Gateway
|
||||
|
||||
|
@ -91,45 +104,30 @@ All channels of a device share one configuration parameter defined on device lev
|
|||
All readable group addresses are queried by openHAB during startup.
|
||||
If readInterval is not specified or set to 0, no further periodic reading will be triggered (default: 0).
|
||||
|
||||
#### Standard Channel Types
|
||||
#### Channel Types
|
||||
|
||||
Standard channels are used most of the time.
|
||||
They are used in the common case where the physical state is owned by a device within the KNX bus, e.g. by a switch actuator who "knows" whether the light is turned on or off, or by a temperature sensor which reports the room temperature regularly.
|
||||
|
||||
Note: After changing the DPT of already existing Channels, openHAB needs to be restarted for the changes to become effective.
|
||||
Control channel types (suffix `-control`) are used for cases where the KNX bus does not own the physical state of a device.
|
||||
This could be the case if e.g. a lamp from another binding should be controlled by a KNX wall switch.
|
||||
When a `GroupValueRead` telegram is sent from the KNX bus to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
|
||||
##### Channel Type "switch"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-------------------------------------|-------------|
|
||||
| ga | Group address for the binary switch | 1.001 |
|
||||
|
||||
##### Channel Type "dimmer"
|
||||
##### Channel Type `color`, `color-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| hsb | Group address for the color | 232.600 |
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
| position | Group address brightness | 5.001 |
|
||||
| increaseDecrease | Group address for relative brightness | 3.007 |
|
||||
|
||||
##### Channel Type "color"
|
||||
The `hsb` address supports DPT 242.600 and 251.600.
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| hsb | Group address for color | 232.600 |
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
Some RGB/RGBW products (e.g. MDT) support HSB values for DPT 232.600 instead of RGB.
|
||||
This is supported as "vendor-specific DPT" with a value of 232.60000.
|
||||
|
||||
##### Channel Type "rollershutter"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-----------------------------------------|-------------|
|
||||
| upDown | Group address for relative movement | 1.008 |
|
||||
| stopMove | Group address for stopping | 1.010 |
|
||||
| position | Group address for the absolute position | 5.001 |
|
||||
|
||||
##### Channel Type "contact"
|
||||
##### Channel Type `contact`, `contact-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
|
@ -138,32 +136,63 @@ Note: After changing the DPT of already existing Channels, openHAB needs to be r
|
|||
*Attention:* Due to a bug in the original implementation, the states for DPT 1.009 are inverted (i.e. `1` is mapped to `OPEN` instead of `CLOSE`).
|
||||
A change would break all existing installations and is therefore not implemented.
|
||||
|
||||
##### Channel Type "number"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
Note: Using the Units Of Measurement feature of openHAB (Quantitytype) requires that the DPT value is set correctly.
|
||||
Automatic type conversion will be applied if required.
|
||||
|
||||
##### Channel Type "string"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 16.001 |
|
||||
|
||||
##### Channel Type "datetime"
|
||||
##### Channel Type `datetime`, `datetime-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 19.001 |
|
||||
|
||||
##### Channel Type `dimmer`, `dimmer-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
|
||||
##### Channel Type `number`, `number-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
Note: The `number` channel has full support for Units Of Measurement (UoM).
|
||||
|
||||
Using the UoM feature of openHAB (QuantityType) requires that the DPT value is set correctly.
|
||||
Automatic type conversion will be applied if required.
|
||||
|
||||
Incoming values from the KNX bus are converted to values with units (e.g. `23 °C`).
|
||||
If the channel is linked to the correct item-type (`Number:Temperature` in this case) the display unit can be controlled by item metadata (e.g. `%.1f °F` for 1 digit of precision in Fahrenheit).
|
||||
The unit is stripped if the channel is linked to a plain number item (type `Number`).
|
||||
|
||||
Outgoing values with unit are first converted to the unit associated with the DPT (e.g. a value of `10 °F` is converted to `-8.33 °C` if the channel has DPT 9.001).
|
||||
Values from plain number channels are sent as-is (without any conversion).
|
||||
|
||||
##### Channel Type `rollershutter`, `rollershutter-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-----------------------------------------|-------------|
|
||||
| upDown | Group address for relative movement | 1.008 |
|
||||
| stopMove | Group address for stopping | 1.010 |
|
||||
| position | Group address for the absolute position | 5.001 |
|
||||
|
||||
##### Channel Type `string`, `string-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 16.001 |
|
||||
|
||||
##### Channel Type `switch`, `switch-control`
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|-----------|-------------------------------------|-------------|
|
||||
| ga | Group address for the binary switch | 1.001 |
|
||||
|
||||
#### Control Channel Types
|
||||
|
||||
In contrast to the standard channels above, the control channel types are used for cases where the KNX bus does not own the physical state of a device.
|
||||
This could for example be the case if a lamp from another binding should be controlled by a KNX wall switch.
|
||||
If from the KNX bus a `GroupValueRead` telegram is sent to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
When a `GroupValueRead` telegram is sent from the KNX bus to a *-control Channel, the bridge responds with a `GroupValueResponse` telegram to the KNX bus.
|
||||
|
||||
##### Channel Type "switch-control"
|
||||
|
||||
|
@ -180,14 +209,6 @@ If from the KNX bus a `GroupValueRead` telegram is sent to a *-control Channel,
|
|||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
| frequency | Increase/Decrease frequency in milliseconds in case the binding should handle that (0 if the KNX device sends the commands repeatedly itself) | 0 |
|
||||
|
||||
##### Channel Type "color-control"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|------------------|----------------------------------------|-------------|
|
||||
| hsb | Group address for color | 232.600 |
|
||||
| switch | Group address for the binary switch | 1.001 |
|
||||
| position | Group address of the absolute position | 5.001 |
|
||||
| increaseDecrease | Group address for relative movement | 3.007 |
|
||||
|
||||
##### Channel Type "rollershutter-control"
|
||||
|
||||
|
@ -212,6 +233,8 @@ A change would break all existing installations and is therefore not implemented
|
|||
|-----------|---------------|-------------|
|
||||
| ga | Group address | 9.001 |
|
||||
|
||||
For UoM support see the explanations of the `number` channel.
|
||||
|
||||
##### Channel Type "string-control"
|
||||
|
||||
| Parameter | Description | Default DPT |
|
||||
|
@ -360,7 +383,7 @@ Color demoColorLight "Color [%s]" <light> { c
|
|||
Dimmer demoDimmer "Dimmer [%d %%]" <light> { channel="knx:device:bridge:generic:demoDimmer" }
|
||||
Rollershutter demoRollershutter "Shade [%d %%]" <rollershutter> { channel="knx:device:bridge:generic:demoRollershutter" }
|
||||
Contact demoContact "Front Door [%s]" <frontdoor> { channel="knx:device:bridge:generic:demoContact" }
|
||||
Number demoTemperature "Temperature [%.1f °C]" <temperature> { channel="knx:device:bridge:generic:demoTemperature" }
|
||||
Number:Temperature demoTemperature "Temperature [%.1f °C]" <temperature> { channel="knx:device:bridge:generic:demoTemperature" }
|
||||
String demoString "Message of the day [%s]" { channel="knx:device:bridge:generic:demoString" }
|
||||
DateTime demoDatetime "Alarm [%1$tH:%1$tM]" { channel="knx:device:bridge:generic:demoDatetime" }
|
||||
```
|
||||
|
|
|
@ -0,0 +1,55 @@
|
|||
---
|
||||
id: vat
|
||||
label: VAT
|
||||
title: VAT - Transformation Services
|
||||
type: transform
|
||||
description: "The VAT Transformation Service adds VAT (Value-Added Tax) to a given input amount."
|
||||
since: 3x
|
||||
install: manual
|
||||
---
|
||||
|
||||
<!-- Attention authors: Do not edit directly. Please add your changes to the appropriate source repository -->
|
||||
|
||||
{% include base.html %}
|
||||
|
||||
# VAT Transformation Service
|
||||
|
||||
The VAT Transformation Service adds VAT (Value-Added Tax) to a given input amount.
|
||||
The input string must be either an ISO 3166 alpha-2 country code or a percentage, i.e. numerical format.
|
||||
|
||||
## Examples
|
||||
|
||||
### Display
|
||||
|
||||
```java
|
||||
Number CurrentSpotPrice "Current Spot Price incl. VAT [VAT(12.5):%s]" <price>
|
||||
```
|
||||
|
||||
### In a Rule
|
||||
|
||||
Add Danish VAT to price:
|
||||
|
||||
```java
|
||||
var Number price = 499
|
||||
logInfo("Price", "Price incl. VAT: " + transform("VAT", "DK", price.toString))
|
||||
```
|
||||
|
||||
## Usage as a Profile
|
||||
|
||||
The functionality of this `TransformationService` can also be used in a `Profile` on an `ItemChannelLink`.
|
||||
This is the most powerful usage since VAT will be added without providing any explicit country code, percentage or configuration.
|
||||
To use this, an `.items` file can be configured as follows:
|
||||
|
||||
```java
|
||||
Number CurrentSpotPrice "Current Spot Price" <price> { channel="<channelUID>" [profile="transform:VAT"] }
|
||||
```
|
||||
|
||||
To override VAT percentage for configured system country:
|
||||
|
||||
```java
|
||||
Number CurrentSpotPrice "Current Spot Price" <price> { channel="<channelUID>" [profile="transform:VAT", percentage="12.5"] }
|
||||
```
|
||||
|
||||
If VAT is not known for the configured country or the provided percentage is invalid, the default is 0%, so the input value will be put into the transformation without any changes.
|
||||
|
||||
Please note: This profile is a one-way transformation, i.e. only values from a device towards the item are changed, the other direction is left untouched.
|
Loading…
Reference in New Issue