Updated external content (Jenkins build 1820)

pull/2219/head
openHAB Build Server 2023-12-10 12:51:09 +00:00
parent d4126c0fc2
commit 02249395f7
17 changed files with 653 additions and 1063 deletions

File diff suppressed because one or more lines are too long

View File

@ -19,7 +19,7 @@ This is the binding for [Jellyfin](https://jellyfin.org) the volunteer-built med
Stream to any device from your own server, with no strings attached.
Your media, your server, your way.
This binding allows connect to Jellyfin clients that supports remote control, it's build on top of the official Jellyfin kotlin sdk.
Compatible with Jellyfin servers from version 10.8.1, recommended 10.8.11.
Compatible with Jellyfin servers from version 10.8.1, recommended 10.8.13.
## Supported Things

View File

@ -76,22 +76,25 @@ NOTE: Some channels will only show up if the hardware has the required sensor an
| Channel Type ID | Item Type | | Description |
|-----------------|------------------------|----|------------------------------------------------------------------------------------|
| rainsensor | Switch | RO | This channel indicates whether rain is detected by the device or not. |
| sensor2 | Switch | RO | This channel is for the second sensor (if your hardware supports it). |
| cloudConnected | Switch | RO | If the device is fully connected to the OpenSprinkler cloud this will show as 'ON'.|
| currentDraw | Number:ElectricCurrent | RO | Shows the current draw of the device. |
| waterlevel | Number:Dimensionless | RO | This channel shows the current water level in percent (0-250%). The water level is |
| | | | calculated based on the weather and influences the duration of the water programs. |
| signalStrength | Number | RO | Shows how strong the WiFi Signal is. |
| enablePrograms | Switch | RW | Allow programs to auto run. When OFF, manually started stations will still work. |
| flowSensorCount | Number:Dimensionless | RO | Shows the number of pulses the optional water flow sensor has reported. |
| programs | String | RW | Displays a list of the programs that are setup in your OpenSprinkler and when |
| | | | selected will start that program for you. |
| stations | String | RW | Display a list of stations that can be run when selected to the length of time set |
| | | | in the `nextDuration` channel. |
| nextDuration | Number:Time | RW | The time the station will open for when any stations are selected from the |
| | | | `stations` channel. Defaults to 30 minutes if not set. |
| resetStations | Switch | RW | The ON command will stop all stations immediately, including those waiting to run. |
| enablePrograms | Switch | RW | Allow programs to auto run. When OFF, manually started stations will still work. |
| pausePrograms | Number:Time | RW | Sets/Shows the amount of time that programs will be paused for. |
| programs | String | RW | Displays a list of the programs that are setup in your OpenSprinkler and when |
| | | | selected will start that program for you. |
| rainDelay | Number:Time | RW | Sets/Shows the amount of time (hours) that rain has caused programs to be delayed. |
| rainsensor | Switch | RO | This channel indicates whether rain is detected by the device or not. |
| resetStations | Switch | RW | The ON command will stop all stations immediately, including those waiting to run. |
| sensor2 | Switch | RO | This channel is for the second sensor (if your hardware supports it). |
| signalStrength | Number | RO | Shows how strong the WiFi Signal is. |
| stations | String | RW | Display a list of stations that can be run when selected to the length of time set |
| | | | in the `nextDuration` channel. |
| waterlevel | Number:Dimensionless | RO | This channel shows the current water level in percent (0-250%). The water level is |
| | | | calculated based on the weather and influences the duration of the water programs. |
| queuedZones | Number | RO | A count of how many zones are running and also waiting to run in the queue. |
## Textual Example

View File

@ -47,11 +47,12 @@ different pilight `bridge` things.
The `bridge` requires the following configuration parameters:
| Parameter Label | Parameter ID | Description | Required |
|-----------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|
| IP Address | ipAddress | Host name or IP address of the pilight daemon | yes |
| Port | port | Port number on which the pilight daemon is listening. Default: 5000 | yes |
| Delay | delay | Delay (in millisecond) between consecutive commands. Recommended value without band pass filter: 1000. Recommended value with band pass filter: somewhere between 200-500. Default: 500 | no |
| Parameter Label | Parameter ID | Description | Required |
|----------------------|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|
| IP Address | ipAddress | Host name or IP address of the pilight daemon | yes |
| Port | port | Port number on which the pilight daemon is listening. Default: 5000 | yes |
| Delay | delay | Delay (in millisecond) between consecutive commands. Recommended value without band pass filter: 1000. Recommended value with band pass filter: somewhere between 200-500. Default: 500 | no |
| Background Discovery | backgroundDiscovery | Whether pilight devices for this Bridge should automatically be discovered. Default: true | no |
Important: you must explicitly configure the port in the pilight daemon config or otherwise a random port will be used
and the binding will not be able to connect.
@ -101,13 +102,13 @@ things from them.
### pilight.things
```java
Bridge pilight:bridge:raspi "Pilight Daemon raspi" [ ipAddress="192.168.1.1", port=5000 ] {
Bridge pilight:bridge:raspi "Pilight Daemon raspi" [ ipAddress="192.168.1.1", port=5000, backgroundDiscovery=false ] {
Thing switch office "Office" [ name="office" ]
Thing dimmer piano "Piano" [ name="piano" ]
Thing generic weather "Weather" [ name="weather" ] {
Channels:
State Number : temperature [ property="temperature"]
State Number : humidity [ property="humidity"]
Type number : temperature "Temperature" [ property="temperature"]
Type number : humidity "Humidity" [ property="humidity"]
}
}
```

View File

@ -1,236 +0,0 @@
---
layout: documentation
title: ADC-T3000 - ZWave
---
{% include base.html %}
# ADC-T3000 Alarm.com Smart Thermostat
This describes the Z-Wave device *ADC-T3000*, manufactured by *Building 36 Technologies* with the thing type UID of ```building36_adct3000_00_000```.
The device is in the category of *HVAC*, defining Air condition devices, Fans.
![ADC-T3000 product image](https://opensmarthouse.org/zwavedatabase/1248/image/)
The ADC-T3000 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
## Overview
* Intelligently Connected with Alarm.com (Alarm.com account required)
* Remote Access and Control
* Custom Schedules
* Critical Temperature Alerts and Geo-Services Automation
* Can be paired with Alarm.com Temperature Sensor ADC-S2000-T-RA for enhanced climate control and improved energy savings (sold separately)
### Inclusion Information
1. Press the MENU button.
2. Select SETTINGS.
3. Select NETWORK.
4. Select ADD.
5. Thermostat will display "Network Add In Progress" and the 4-digit DSK pin.  The pin can be used for S2 inclusion.
### Exclusion Information
1. Press the MENU button.
2. Select SETTINGS.
3. Select NETWORK.
4. Select REMOVE.
### General Usage Information
#### Buttons
* **MENU** (top left): Access options to change the mode, fan, settings, and other features.
* **SELECT** (bottom left): Select options in the **MENU**.
* **UP** (top right): Adjust set point up or navigate the **MENU**.
* **DOWN** (bottom right): Adjust set point down or navigate the **MENU**.
#### Modes
* **HEAT**: Will activate the heating system.
* **COOL**: Will activate the air conditioner.
* **AUTO**: Will select either the HEAT or COOL mode automatically.
* **EMER**: For use with heat pumps only. Will bypass the heat pump and enable auxiliary/emergency heat.
* **OFF**: The system will not heat or cool.
## Channels
The following table summarises the channels available for the ADC-T3000 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
| Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
| Sensor (voltage) | sensor_voltage | sensor_voltage | | Number |
| Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
| Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
| Operating State | thermostat_state | thermostat_state | Temperature | Number |
| Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
| Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
| Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | | |
| Thermostat fan state | thermostat_fanstate | thermostat_fanstate | | |
| Alarm (power) | alarm_power | alarm_power | Energy | Switch |
| Alarm (system) | alarm_system | alarm_system | | Switch |
| Battery Level | battery-level | system.battery_level | Battery | Number |
| Clock Time Offset | time_offset | time_offset | Time | Number |
### Sensor (relative humidity)
Indicates the current relative humidity.
The ```sensor_relhumidity``` channel is of type ```sensor_relhumidity``` and supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device.
### Sensor (voltage)
Indicates the current voltage.
The ```sensor_voltage``` channel is of type ```sensor_voltage``` and supports the ```Number``` item. This is a read only channel so will only be updated following state changes from the device.
### Sensor (temperature)
Indicates the current temperature.
The ```sensor_temperature``` channel is of type ```sensor_temperature``` and supports the ```Number:Temperature``` item and is in the ```Temperature``` category.
### Thermostat mode
Sets the thermostat.
The ```thermostat_mode``` channel is of type ```thermostat_mode``` and supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
| Value | Label |
|-------|-----------|
| 0 | Off |
| 1 | Heat |
| 2 | Cool |
| 3 | Auto |
| 4 | Aux Heat |
| 5 | Resume |
| 6 | Fan Only |
| 7 | Furnace |
| 8 | Dry Air |
| 9 | Moist Air |
| 10 | Auto Changeover |
| 11 | Heat Economy |
| 12 | Cool Economy |
| 13 | Away |
### Operating State
Sets the thermostat operating state.
The ```thermostat_state``` channel is of type ```thermostat_state``` and supports the ```Number``` item and is in the ```Temperature``` category.
The following state translation is provided for this channel to the ```Number``` item type -:
| Value | Label |
|-------|-----------|
| 0 | Idle |
| 1 | Heating |
| 2 | Cooling |
| 3 | Fan Only |
| 4 | Pending Heat |
| 5 | Pending Cool |
| 6 | Vent / Economiser |
### Setpoint (cooling)
Sets the thermostat setpoint.
The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category.
### Setpoint (heating)
Sets the thermostat setpoint.
The ```thermostat_setpoint``` channel is of type ```thermostat_setpoint``` and supports the ```Number:Temperature``` item and is in the ```Heating``` category.
### Thermostat fan mode
Channel type information on this channel is not found.
### Thermostat fan state
Channel type information on this channel is not found.
### Alarm (power)
Indicates if a power alarm is triggered.
The ```alarm_power``` channel is of type ```alarm_power``` and supports the ```Switch``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Alarm (system)
Indicates if a system alarm is triggered.
The ```alarm_system``` channel is of type ```alarm_system``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
### Clock Time Offset
Provides the current time difference for the devices time.
The ```time_offset``` channel is of type ```time_offset``` and supports the ```Number``` item and is in the ```Time``` category.
## Device Configuration
The device has no configuration parameters defined.
## Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ADC-T3000 supports 1 association group.
### Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 4 nodes.
## Technical Information
### Endpoints
#### Endpoint 0
| Command Class | Comment |
|---------------|---------|
| COMMAND_CLASS_NO_OPERATION_V1| |
| COMMAND_CLASS_BASIC_V1| |
| COMMAND_CLASS_SENSOR_MULTILEVEL_V10| |
| COMMAND_CLASS_THERMOSTAT_MODE_V1| |
| COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1| |
| COMMAND_CLASS_THERMOSTAT_SETPOINT_V1| |
| COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| |
| COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |
| COMMAND_CLASS_CONFIGURATION_V1| |
| COMMAND_CLASS_ALARM_V7| |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| |
| COMMAND_CLASS_POWERLEVEL_V1| |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| |
| COMMAND_CLASS_BATTERY_V1| |
| COMMAND_CLASS_CLOCK_V1| |
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_VERSION_V2| |
### Documentation Links
* [Product Manual](https://opensmarthouse.org/zwavedatabase/1248/reference/adct3000.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1248).

View File

@ -1,204 +0,0 @@
---
layout: documentation
title: GE 58433 - ZWave
---
{% include base.html %}
# GE 58433 GE Enbrighten Z-Wave Plus Smart Switch
This describes the Z-Wave device *GE 58433*, manufactured by *Jasco Products* with the thing type UID of ```ge_58433_00_000```.
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
![GE 58433 product image](https://opensmarthouse.org/zwavedatabase/1589/image/)
The GE 58433 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
## Overview
Home automation is even smarter with the Enbrighten Z-Wave In-Wall Smart Switch with QuickFit™ and SimpleWire™. When paired with a compatible hub, the hardwired smart switch operates wall, ceiling and accent lighting through individual commands and programmed settings. Wirelessly control and schedule indoor or outdoor fixtures for effortless management of your home. Your automation possibilities are seemingly infinite when connected to hubs from Ring, Wink, SmartThings, HomeSeer, Vera, American Standard and more.
Home automation is even smarter with the GE Enbrighten Z-Wave Plus In-Wall Smart Switch with QuickFit™ and SimpleWire™. When paired with a compatible hub, the hardwired smart switch operates wall, ceiling and accent lighting through individual commands and programmed settings. Wirelessly control and schedule indoor or outdoor fixtures for effortless management of your home. Your automation possibilities are seemingly infinite when connected to hubs from Ring, Wink, SmartThings, HomeSeer, Vera, Nexia and more.
### Inclusion Information
Once the controller is ready to include your device, press up and release on the toggle to include it in the network.
Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance.
1. Once the controller is ready to include your device, press up and release on the toggle to include it in the network. 
2. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. 
### Exclusion Information
Once the controller is ready to exclude your device, press up and release on the toggle to exclude it from the network.
1. Once the controller is ready to include your device, press up and release on the toggle to include it in the network. 
2. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. 
### General Usage Information
## Channels
The following table summarises the channels available for the GE 58433 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Scene Number | scene_number | scene_number | | Number |
| Scene Number | scene_number | scene_number | | Number |
### Switch
Switch the power on and off.
The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category.
### Scene Number
Triggers when a scene button is pressed.
The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item.
### Scene Number
Triggers when a scene button is pressed.
The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item.
This channel provides the scene, and the event as a decimal value in the form ```<scene>.<event>```. The scene number is set by the device, and the event is as follows -:
| Event ID | Event Description |
|----------|--------------------|
| 0 | Single key press |
| 1 | Key released |
| 2 | Key held down |
| 3 | Double keypress |
| 4 | Tripple keypress |
| 5 | 4 x keypress |
| 6 | 5 x keypress |
## Device Configuration
The following table provides a summary of the 3 configuration parameters available in the GE 58433.
Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|-------|-------|-------------|
| 3 | LED Mode | LED Indication Configuration |
| 4 | Invert Switch | Invert Switch |
| 19 | Alternate Exclusion | Set Alternate Exclusion Mode |
### Parameter 3: LED Mode
LED Indication Configuration
Sets mode for LED inside toggle switch
The following option values may be configured -:
| Value | Description |
|--------|-------------|
| 0 | LED ON when switch is OFF |
| 1 | LED ON when switch is ON |
| 2 | LED always OFF |
| 3 | LED Always ON |
The manufacturer defined default value is ```2``` (LED always OFF).
This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```.
### Parameter 4: Invert Switch
Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4s value to “1”.
The following option values may be configured -:
| Value | Description |
|--------|-------------|
| 0 | Normal Switch Install |
| 1 | Inverted Switch Install |
The manufacturer defined default value is ```0``` (Normal Switch Install).
This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```.
### Parameter 19: Alternate Exclusion
Set Alternate Exclusion Mode
The following option values may be configured -:
| Value | Description |
|--------|-------------|
| 0 | Press any button on the switch |
| 1 | Alternate Exclusion |
The manufacturer defined default value is ```0``` (Press any button on the switch).
This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```.
## Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE 58433 supports 3 association groups.
### Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Lifeline
Association group 1 supports 5 nodes.
### Group 2: Group 2
Basic Set single click
Association group 2 supports 5 nodes.
### Group 3: Basic Set double click
Association group 3 supports 5 nodes.
## Technical Information
### Endpoints
#### Endpoint 0
| Command Class | Comment |
|---------------|---------|
| COMMAND_CLASS_NO_OPERATION_V1| |
| COMMAND_CLASS_BASIC_V1| |
| COMMAND_CLASS_APPLICATION_STATUS_V1| |
| COMMAND_CLASS_SWITCH_BINARY_V1| |
| COMMAND_CLASS_SCENE_ACTIVATION_V1| |
| COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| |
| COMMAND_CLASS_TRANSPORT_SERVICE_V1| |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| |
| COMMAND_CLASS_CENTRAL_SCENE_V3| |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |
| COMMAND_CLASS_SUPERVISION_V1| |
| COMMAND_CLASS_CONFIGURATION_V1| |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| |
| COMMAND_CLASS_POWERLEVEL_V1| |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| |
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_VERSION_V2| |
| COMMAND_CLASS_INDICATOR_V3| |
| COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |
| COMMAND_CLASS_SECURITY_2_V1| |
### Documentation Links
* [Manual 58433](https://opensmarthouse.org/zwavedatabase/1589/reference/58433_qsg_v2.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1589).

View File

@ -1,171 +0,0 @@
---
layout: documentation
title: Keemple KP-SO-02 - ZWave
---
{% include base.html %}
# Keemple KP-SO-02 Wall Plug Switch
This describes the Z-Wave device *Keemple KP-SO-02*, manufactured by *Keemplecom Limited* with the thing type UID of ```keemple_wallplug_04_000```.
This version of the device is limited to firmware versions above 4.0
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
![Keemple KP-SO-02 product image](https://opensmarthouse.org/zwavedatabase/1359/image/)
The Keemple KP-SO-02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
## Overview
This Plug provides line voltage, current load, power consumption and energy consumption measuring.
Voltage The Supply Power Voltage For Plug.
Current The Current for the Electric Device Connect to Plug Consumption.
Power Power Consumed by an Electric Device in an instant, unit: Watt (W).
Energy Energy Consumed by an Electric Device through a Time Period. Most commonly measured in Kilowatt-hours (kWh). One kilowatt-hour is Equal to One Kilowatt of Power Consumed over a Period of One Hour, 1kWh = 1000Wh.0Wh.
### Inclusion Information
1. Connect a plug to power and wait at least 20 seconds.
2. Set ZWave controller or ZWave gateway into inclusion mode (refer to the controller or gateway operating manual).
3. Briefly press the plug button three times (the LED will alternately flash gree five times).
### Exclusion Information
1. Connect a plug to power and wait at least 20 seconds.
2. et ZWave controller or ZWave gateway into exclusion mode (refer to the controller or gateway operating manual).
3. Briefly press the plug button three times (the LED will alternately flash pink five times).
### General Usage Information
## Channels
The following table summarises the channels available for the Keemple KP-SO-02 -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Alarm (power) | alarm_power | alarm_power | Energy | Switch |
### Switch
Switch the power on and off.
The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category.
### Electric meter (watts)
Indicates the instantaneous power consumption.
The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (kWh)
Indicates the energy consumption (kWh).
The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (volts)
Indicates the instantaneous voltage.
The ```meter_voltage``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Electric meter (amps)
Indicates the instantaneous current consumption.
The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
### Alarm (power)
Indicates if a power alarm is triggered.
The ```alarm_power``` channel is of type ```alarm_power``` and supports the ```Switch``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
## Device Configuration
The device has no configuration parameters defined.
## Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Keemple KP-SO-02 supports 3 association groups.
### Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Assigned to Plugs status - On/Off. Allows for receiving control command from trigger devices whenever the Plug is turned On or Off.
NOTIFICATION\_REPORT\_V4
METER\_REPORT\_V4
SWITCH\_BINARY\_REPORT
DEVICE\_RESET\_LOCALLY_NOTIFICATION
Association group 1 supports 1 node.
### Group 2: Group 2
Sending control commands to associated devices. If current load is over the max current defined in parameter #3, the Plug will send a BASIC\_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC\_SET (0x00).
BASIC_SET
Association group 2 supports 5 nodes.
### Group 3: Group 3
Send Notification to associated devices.
NOTIFICATION\_REPORT\_V4
Association group 3 supports 5 nodes.
## Technical Information
### Endpoints
#### Endpoint 0
| Command Class | Comment |
|---------------|---------|
| COMMAND_CLASS_NO_OPERATION_V1| |
| COMMAND_CLASS_BASIC_V1| |
| COMMAND_CLASS_SWITCH_BINARY_V1| |
| COMMAND_CLASS_METER_V3| |
| COMMAND_CLASS_TRANSPORT_SERVICE_V1| |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |
| COMMAND_CLASS_SUPERVISION_V1| |
| COMMAND_CLASS_CONFIGURATION_V1| |
| COMMAND_CLASS_ALARM_V8| |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| |
| COMMAND_CLASS_POWERLEVEL_V1| |
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_VERSION_V2| |
| COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |
| COMMAND_CLASS_SECURITY_V1| |
| COMMAND_CLASS_SECURITY_2_V1| |
### Documentation Links
* [User Manual PL](https://opensmarthouse.org/zwavedatabase/1359/reference/Keemple_KP-SO-02_manual_PL.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1359).

View File

@ -1,19 +1,20 @@
---
layout: documentation
title: ZEN51 - ZWave
title: ZEN51 LR - ZWave
---
{% include base.html %}
# ZEN51 Dry Contact Relay
This describes the Z-Wave device *ZEN51*, manufactured by *[Zooz](http://www.getzooz.com/)* with the thing type UID of ```zooz_zen51_00_000```.
# ZEN51 LR Dry Contact Relay
This describes the Z-Wave device *ZEN51 LR*, manufactured by *[Zooz](http://www.getzooz.com/)* with the thing type UID of ```zooz_zen51lr_01_050```.
This version of the device is limited to firmware versions above 1.50
The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
![ZEN51 product image](https://opensmarthouse.org/zwavedatabase/1486/image/)
![ZEN51 LR product image](https://opensmarthouse.org/zwavedatabase/1592/image/)
The ZEN51 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The ZEN51 LR supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
## Overview
@ -25,18 +26,34 @@ SmartStart and S2 authenticated security for a truly protected smart home
Installs behind the existing wall switch or at the fixture (if neutral is not available in the switch box)
On/off Z-Wave control for 120V and dry contact applications: great for lighting control or 120V load monitoring (sump pumps, motion lights)
700 series Z-Wave chip: greater coverage for a stronger mesh network
SmartStart and S2 authenticated security for a truly protected smart home
Installs behind the existing wall switch or at the fixture (if neutral is not available in the switch box)
### Inclusion Information
1. Initiate inclusion (pairing) in the app (or web interface).
2. Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.
3. The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.
1. Initiate inclusion (pairing) in the app (or web interface).
2. Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.
3. The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.
### Exclusion Information
1. Bring your Z-Wave gateway (hub) close to the relay if possible
2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)
3. Click the on the relay 3 times quickly (theZ-Wave button LED indicator will start blinking green)
4. Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list.
1. Bring your Z-Wave gateway (hub) close to the relay if possible
2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)
3. Click the on the relay 3 times quickly (theZ-Wave button LED indicator will start blinking green)
4. Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list.
1. Initiate inclusion (pairing) in the app (or web interface).
2. Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.
3. The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.
### General Usage Information
@ -44,7 +61,7 @@ Installs behind the existing wall switch or at the fixture (if neutral is not av
## Channels
The following table summarises the channels available for the ZEN51 -:
The following table summarises the channels available for the ZEN51 LR -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
@ -52,8 +69,6 @@ The following table summarises the channels available for the ZEN51 -:
| Scene Number | scene_number | scene_number | | Number |
### Switch
Relay output
Switch the power on and off.
The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category.
@ -78,7 +93,7 @@ This channel provides the scene, and the event as a decimal value in the form ``
## Device Configuration
The following table provides a summary of the 11 configuration parameters available in the ZEN51.
The following table provides a summary of the 12 configuration parameters available in the ZEN51 LR.
Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
@ -94,6 +109,7 @@ Detailed information on each parameter can be found in the sections below.
| 9 | Relay Type Behavior | Act as a normally open or a normally closed relay |
| 10 | Timer Units | Time units for parameters 2 and 3. |
| 11 | Impulse Duration for 3-Way Impulse Control | Duration of the impulse if using the relay with 3-way impulse control |
| 12 | External Switch Multiple Click Detection | Enable or disable the external switch multiple click detection. |
### Parameter 1: LED Indicator
@ -299,11 +315,29 @@ The manufacturer defined default value is ```10```.
This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```.
### Parameter 12: External Switch Multiple Click Detection
Enable or disable the external switch multiple click detection.
0 disable the external switch multiple click detection. Clicking the external switch 3 times quickly for inclusion/exclusion will be disabled, and the central scene actions (multi-tap) will be disabled. 
1 Enable the external switch multiple click detection (default).
The following option values may be configured, in addition to values in the range 0 to 1 -:
| Value | Description |
|--------|-------------|
| 0 | Disable the external switch multiple click detection |
| 1 | Enable the external switch multiple click detection (default) |
The manufacturer defined default value is ```1``` (Enable the external switch multiple click detection (default)).
This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```.
## Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN51 supports 2 association groups.
The ZEN51 LR supports 2 association groups.
### Group 1: Group 1; Lifeline communication
@ -349,9 +383,10 @@ Association group 2 supports 5 nodes.
### Documentation Links
* [ZEN51 Manual](https://opensmarthouse.org/zwavedatabase/1486/reference/zooz-700-series-z-wave-plus-dry-contact-relay-zen51-manual.pdf)
* [manual](https://opensmarthouse.org/zwavedatabase/1592/reference/zooz-700-series-z-wave-plus-dry-contact-relay-zen51-manual.pdf)
* [parameters](https://opensmarthouse.org/zwavedatabase/1592/reference/zooz-700-series-z-wave-plus-dry-contact-relay-zen51-parameters.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1486).
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1592).

View File

@ -0,0 +1,312 @@
---
layout: documentation
title: ZEN55 LR - ZWave
---
{% include base.html %}
# ZEN55 LR DC Signal Sensor (Smoke and CO Detector Bridge)
This describes the Z-Wave device *ZEN55 LR*, manufactured by *[Zooz](http://www.getzooz.com/)* with the thing type UID of ```zooz_zen55lr_00_000```.
The device is in the category of *Sensor*, defining Device used to measure something.
![ZEN55 LR product image](https://opensmarthouse.org/zwavedatabase/1593/image/)
The ZEN55 LR supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
## Overview
* Z-Wave alerts from low-voltage trigger signals
* Connect to smoke or CO detectors to monitor activity
* 120 V relay to control a security siren or lights
* Installs in the box with the last smoke detector in series
* 800 series Z-Wave chip for better range and faster control
* Z-Wave Long Range for ultra reliable no-mesh communication
* Advanced settings to customize the devices behavior
* Built-in Z-Wave signal repeater for boosted communication
* SmartStart and S2 Authenticate Security for a safer network
### Inclusion Information
1. Initiate inclusion (pairing) in the app (or web interface).
2. Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.
3. The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.
### Exclusion Information
1. Bring your Z-Wave gateway (hub) close to the relay if possible
2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)
3. Click the on the relay 3 times quickly (the Z-Wave button LED indicator will start blinking green)
4. Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list.
### General Usage Information
## Channels
The following table summarises the channels available for the ZEN55 LR -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|--------------|------------|--------------|----------|-----------|
| Alarm (smoke) | alarm_smoke | alarm_smoke | Smoke | Switch |
| Alarm (CO) | alarm_co | alarm_co | | Switch |
### Alarm (smoke)
Indicates if a smoke is triggered.
The ```alarm_smoke``` channel is of type ```alarm_smoke``` and supports the ```Switch``` item and is in the ```Smoke``` category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
### Alarm (CO)
Indicates if the carbon monoxide alarm is triggered.
The ```alarm_co``` channel is of type ```alarm_co``` and supports the ```Switch``` item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the ```Switch``` item type -:
| Value | Label |
|-------|-----------|
| OFF | OK |
| ON | Alarm |
## Device Configuration
The following table provides a summary of the 9 configuration parameters available in the ZEN55 LR.
Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|-------|-------|-------------|
| 1 | LED Indicator | Enable or disable the LED indicator to reflect the current on/off status of the connected load (LED on when the load is on, LED off when the load is off). |
| 2 | Relay Alarm Trigger | Use this parameter to automatically trigger the relay to turn the connected load on when alarm is detected on the input (signal) side. |
| 3 | Auto Turn-Off Timer | Use this parameter to set the time after which you want the device connected to the relay to automatically turn off once it has been turned on. The number entered as value corresponds to the number of seconds. |
| 4 | Auto Turn-Off Timer | Use this parameter to set the time after which you want the device connected to the relay to automatically turn on once it has been turned off. The number entered as value corresponds to the number of seconds. |
| 5 | On/Off Status After Power Failure | Set the on/off status for the relay after power failure |
| 6 | Association Reports (Group 2) - Smoke Alarm | Decide when the device will send BASIC_SET commands to devices associated in Group 2 (Smoke Alarm). |
| 7 | Association Reports (Group 3) - CO Alarm | Decide when the device will send BASIC_SET commands to devices associated in Group 3 (CO Alarm). |
| 8 | Disable the Sensors or Relay | After changing this parameter and re-inclusion, the device will show up as a switch, which can be controlled via Z-Wave. |
| 9 | Relay Status Reports | Decide what type of reports the relay part of the device sends back to the hub when it changes status. |
### Parameter 1: LED Indicator
Enable or disable the LED indicator to reflect the current on/off status of the connected load (LED on when the load is on, LED off when the load is off).
The following option values may be configured, in addition to values in the range 0 to 1 -:
| Value | Description |
|--------|-------------|
| 0 | LED Indicator disabled |
| 1 | LED Indicator enabled (default) |
The manufacturer defined default value is ```1``` (LED Indicator enabled (default)).
This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```.
### Parameter 2: Relay Alarm Trigger
Use this parameter to automatically trigger the relay to turn the connected load on when alarm is detected on the input (signal) side.
The following option values may be configured, in addition to values in the range 0 to 1 -:
| Value | Description |
|--------|-------------|
| 0 | auto-trigger disabled |
| 1 | auto-trigger enabled (default) |
The manufacturer defined default value is ```1``` (auto-trigger enabled (default)).
This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```.
### Parameter 3: Auto Turn-Off Timer
Use this parameter to set the time after which you want the device connected to the relay to automatically turn off once it has been turned on. The number entered as value corresponds to the number of seconds.
0 timer disabled (default); 1 4294967295
Values in the range 0 to 4294967294 may be set.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_3_4``` and is of type ```INTEGER```.
### Parameter 4: Auto Turn-Off Timer
Use this parameter to set the time after which you want the device connected to the relay to automatically turn on once it has been turned off. The number entered as value corresponds to the number of seconds.
0 timer disabled (default); 1 4294967295
Values in the range 0 to 4294967294 may be set.
The manufacturer defined default value is ```0```.
This parameter has the configuration ID ```config_4_4``` and is of type ```INTEGER```.
### Parameter 5: On/Off Status After Power Failure
Set the on/off status for the relay after power failure
The following option values may be configured, in addition to values in the range 0 to 2 -:
| Value | Description |
|--------|-------------|
| 0 | forced to OFF (regardless of state prior to power outage) |
| 1 | forced to ON (regardless of state prior to power outage) |
| 2 | remembers and restores on/off status after power failure (default) |
The manufacturer defined default value is ```2``` (remembers and restores on/off status after power failure (default)).
This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```.
### Parameter 6: Association Reports (Group 2) - Smoke Alarm
Decide when the device will send BASIC_SET commands to devices associated in Group 2 (Smoke Alarm).
The following option values may be configured, in addition to values in the range 0 to 5 -:
| Value | Description |
|--------|-------------|
| 0 | BASIC\_SET (0xFF) ON when smoke is detected, BASIC\_SET (0x00) OFF when |
| 1 | BASIC\_SET (0x00) OFF when smoke is detected, BASIC\_SET (0xFF) ON when |
| 2 | BASIC_SET (0xFF) ON when smoke is detected, no commands sent when smok |
| 3 | BASIC_SET (0x00) OFF when smoke is detected, no commands sent when smo |
| 4 | BASIC_SET (0x00) OFF when smoke is not detected, no commands sent when |
| 5 | BASIC_SET (0xFF) ON when smoke is not detected, no commands sent when |
The manufacturer defined default value is ```0``` (BASIC_SET (0xFF) ON when smoke is detected, BASIC_SET (0x00) OFF when ).
This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```.
### Parameter 7: Association Reports (Group 3) - CO Alarm
Decide when the device will send BASIC_SET commands to devices associated in Group 3 (CO Alarm).
The following option values may be configured, in addition to values in the range 0 to 5 -:
| Value | Description |
|--------|-------------|
| 0 | BASIC\_SET (0xFF) ON when CO is detected, BASIC\_SET (0x00) OFF when CO |
| 1 | BASIC\_SET (0x00) OFF when CO is detected, BASIC\_SET (0xFF) ON when CO |
| 2 | BASIC_SET (0xFF) ON when CO is detected, no commands sent when CO is n |
| 3 | BASIC_SET (0x00) OFF when CO is detected, no commands sent when CO is |
| 4 | BASIC_SET (0x00) OFF when CO is not detected, no commands sent when CO |
| 5 | BASIC_SET (0xFF) ON when CO is not detected, no commands sent when CO |
The manufacturer defined default value is ```0``` (BASIC_SET (0xFF) ON when CO is detected, BASIC_SET (0x00) OFF when CO ).
This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```.
### Parameter 8: Disable the Sensors or Relay
After changing this parameter and re-inclusion, the device will show up as a switch, which can be controlled via Z-Wave.
NOTE: You need to exclude and re-include the device to your hub or re-configure (re-interview) the device if the value of this setting is changed.
The following option values may be configured, in addition to values in the range 1 to 7 -:
| Value | Description |
|--------|-------------|
| 1 | Enable smoke and CO sensor endpoints and disable the relay switch endp |
| 2 | Enable the CO sensor endpoint and disable the smoke sensor and relay e |
| 3 | Enable the smoke sensor endpoint and disable the CO sensor and relay e |
| 4 | Enable the smoke sensor, CO sensor, and the relay endpoints (all endpo |
| 5 | Enable the relay and CO sensor endpoints and disable the smoke sensor |
| 6 | Enable the relay and smoke sensor endpoints and disable the CO sensor |
| 7 | Enable the relay endpoint and disable the CO sensor and smoke sensor e |
The manufacturer defined default value is ```1``` (Enable smoke and CO sensor endpoints and disable the relay switch endp).
This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```.
### Parameter 9: Relay Status Reports
Decide what type of reports the relay part of the device sends back to the hub when it changes status.
The following option values may be configured, in addition to values in the range 0 to 2 -:
| Value | Description |
|--------|-------------|
| 0 | binary switch report for Z-Wave control and input control (from the DC |
| 1 | binary switch report for Z-Wave control and basic report for input con |
| 2 | basic report for Z-Wave control and input control (from the DC signal |
The manufacturer defined default value is ```0``` (binary switch report for Z-Wave control and input control (from the DC).
This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```.
## Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN55 LR supports 4 association groups.
### Group 1: Group 1 - Lifeline
Send BASIC REPORT and NOTIFICATION REPORT to Group 1
Association group 1 supports 5 nodes.
### Group 2: Group 2 - Smoke Alarm
Send BASIC SET command
Association group 2 supports 5 nodes.
### Group 3: Group 3 - CO Alarm
Send BASIC SET command
Association group 3 supports 5 nodes.
### Group 4: Group 4
Send BASIC SET command
Association group 4 supports 5 nodes.
## Technical Information
### Endpoints
#### Endpoint 0
| Command Class | Comment |
|---------------|---------|
| COMMAND_CLASS_NO_OPERATION_V1| |
| COMMAND_CLASS_APPLICATION_STATUS_V1| |
| COMMAND_CLASS_TRANSPORT_SERVICE_V1| |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1| |
| COMMAND_CLASS_SUPERVISION_V1| |
| COMMAND_CLASS_CONFIGURATION_V1| |
| COMMAND_CLASS_ALARM_V8| |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| |
| COMMAND_CLASS_POWERLEVEL_V1| |
| COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| |
| COMMAND_CLASS_ASSOCIATION_V2| |
| COMMAND_CLASS_VERSION_V2| |
| COMMAND_CLASS_INDICATOR_V3| |
| COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |
| COMMAND_CLASS_SECURITY_2_V1| |
### Documentation Links
* [manual](https://opensmarthouse.org/zwavedatabase/1593/reference/zooz-800-lr-dc-signal-sensor-zen55-manual.pdf)
* [parameters](https://opensmarthouse.org/zwavedatabase/1593/reference/zooz-800-lr-dc-signal-sensor-zen55-parameters.pdf)
---
Did you spot an error in the above definition or want to improve the content?
You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1593).

View File

@ -89,7 +89,15 @@
<channel id="resetStations" typeId="resetStations"></channel>
<channel id="enablePrograms" typeId="enablePrograms"></channel>
<channel id="rainDelay" typeId="rainDelay"></channel>
<channel id="queuedZones" typeId="queuedZones"></channel>
<channel id="cloudConnected" typeId="cloudConnected"></channel>
<channel id="pausePrograms" typeId="pausePrograms"></channel>
</channels>
<properties>
<property name="thingTypeVersion">1</property>
</properties>
</thing-type>
<channel-type id="rainsensor">
@ -108,6 +116,14 @@
<state readOnly="true"/>
</channel-type>
<channel-type id="cloudConnected">
<item-type>Switch</item-type>
<label>Cloud Connected</label>
<description>If the device is fully connected to the OpenSprinkler cloud this will show as 'ON'.</description>
<category>Sensor</category>
<state readOnly="true"/>
</channel-type>
<channel-type id="waterlevel">
<item-type>Number:Dimensionless</item-type>
<label>Water Level</label>
@ -123,6 +139,13 @@
<state readOnly="true"/>
</channel-type>
<channel-type id="queuedZones">
<item-type>Number</item-type>
<label>Number Of Queued Zones</label>
<description>A count of how many zones are running and also waiting to run in the queue.</description>
<state readOnly="true"/>
</channel-type>
<channel-type id="currentDraw">
<item-type>Number:ElectricCurrent</item-type>
<label>Current Draw</label>
@ -176,6 +199,26 @@
<state readOnly="true" pattern="%.0f min"/>
</channel-type>
<channel-type id="pausePrograms">
<item-type>Number:Time</item-type>
<label>Pause Programs</label>
<description>The duration that all zones will be paused for before resuming the watering.</description>
<category>Time</category>
<state>
<options>
<option value="0s">Not Paused</option>
<option value="15s">15 Seconds</option>
<option value="30s">30 Seconds</option>
<option value="1min">1 Minute</option>
<option value="2min">2 Minutes</option>
<option value="3min">3 Minutes</option>
<option value="4min">4 Minutes</option>
<option value="5min">5 Minutes</option>
<option value="10min">10 Minutes</option>
</options>
</state>
</channel-type>
<channel-type id="nextDuration">
<item-type>Number:Time</item-type>
<label>Next Duration</label>

View File

@ -32,6 +32,12 @@
<default>500</default>
<advanced>true</advanced>
</parameter>
<parameter name="backgroundDiscovery" type="boolean">
<label>Background Discovery</label>
<description>Whether Pilight devices for this bridge should automatically be discovered.</description>
<advanced>true</advanced>
<default>true</default>
</parameter>
</config-description>
</bridge-type>

View File

@ -12,6 +12,7 @@
<parameter name="refreshToken" type="text" required="false">
<label>Refresh Token</label>
<description>Refresh token for account authentication. Please see the documentation on how to get hold of it.</description>
<context>password</context>
</parameter>
</config-description>
</bridge-type>

View File

@ -1,170 +0,0 @@
<?xml version="1.0" encoding="UTF-8"?>
<thing:thing-descriptions bindingId="zwave"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0
https://openhab.org/schemas/thing-description/v1.0.0">
<thing-type id="building36_adct3000_00_000" listed="false">
<label>ADC-T3000 Alarm.com Smart Thermostat</label>
<description><![CDATA[
Alarm.com Smart Thermostat<br /> <h1>Overview</h1><ul><li>Intelligently Connected with Alarm.com (Alarm.com account required)</li> <li>Remote Access and Control</li> <li>Custom Schedules</li> <li>Critical Temperature Alerts and Geo-Services Automation</li> <li>Can be paired with Alarm.com Temperature Sensor ADC-S2000-T-RA for enhanced climate control and improved energy savings (sold separately)</li> </ul> <br /> <h2>Inclusion Information</h2><ol><li>Press the MENU button.</li> <li>Select SETTINGS.</li> <li>Select NETWORK.</li> <li>Select ADD.</li> <li>Thermostat will display "Network Add In Progress" and the 4-digit DSK pin.  The pin can be used for S2 inclusion.</li> </ol> <br /> <h2>Exclusion Information</h2><ol><li>Press the MENU button.</li> <li>Select SETTINGS.</li> <li>Select NETWORK.</li> <li>Select REMOVE.</li> </ol> <br /> <h2>Wakeup Information</h2><p>Wakeup does not seem to be documented, or modifiable through the user interface.</p> <p>It is probably safe to assume that if no common (C) wire is connected, the device will only wake up periodically (perhaps once per hour) to avoid draining the batteries.  If a C wire is connected, there's no reason why it can't stay awake all the time.</p>
]]></description>
<category>HVAC</category>
<!-- CHANNEL DEFINITIONS -->
<channels>
<channel id="sensor_relhumidity" typeId="sensor_relhumidity">
<label>Sensor (relative humidity)</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_SENSOR_MULTILEVEL;type=RELATIVE_HUMIDITY</property>
</properties>
</channel>
<channel id="sensor_voltage" typeId="sensor_voltage">
<label>Sensor (voltage)</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_SENSOR_MULTILEVEL;type=VOLTAGE</property>
</properties>
</channel>
<channel id="sensor_temperature" typeId="sensor_temperature">
<label>Sensor (temperature)</label>
<properties>
<property name="binding:*:QuantityType">COMMAND_CLASS_SENSOR_MULTILEVEL;type=TEMPERATURE</property>
</properties>
</channel>
<channel id="thermostat_mode" typeId="building36_adct3000_00_000_thermostat_mode">
<label>Thermostat mode</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_THERMOSTAT_MODE</property>
</properties>
</channel>
<channel id="thermostat_state" typeId="thermostat_state">
<label>Thermostat Operating State</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_THERMOSTAT_OPERATING_STATE</property>
</properties>
</channel>
<channel id="thermostat_setpoint_cooling" typeId="thermostat_setpoint">
<label>Setpoint (cooling)</label>
<properties>
<property name="binding:*:QuantityType">COMMAND_CLASS_THERMOSTAT_SETPOINT;type=COOLING</property>
</properties>
</channel>
<channel id="thermostat_setpoint_heating" typeId="thermostat_setpoint">
<label>Setpoint (heating)</label>
<properties>
<property name="binding:*:QuantityType">COMMAND_CLASS_THERMOSTAT_SETPOINT;type=HEATING</property>
</properties>
</channel>
<channel id="thermostat_fanmode" typeId="building36_adct3000_00_000_thermostat_fanmode">
<label>Thermostat fan mode</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_THERMOSTAT_FAN_MODE</property>
</properties>
</channel>
<channel id="thermostat_fanstate" typeId="building36_adct3000_00_000_thermostat_fanstate">
<label>Thermostat fan state</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_THERMOSTAT_FAN_STATE</property>
</properties>
</channel>
<channel id="alarm_power" typeId="alarm_power">
<label>Alarm (power)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=POWER_MANAGEMENT</property>
</properties>
</channel>
<channel id="alarm_system" typeId="alarm_system">
<label>Alarm (system)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=SYSTEM</property>
</properties>
</channel>
<channel id="battery-level" typeId="system.battery-level">
<properties>
<property name="binding:*:PercentType">COMMAND_CLASS_BATTERY</property>
</properties>
</channel>
<channel id="time_offset" typeId="time_offset">
<label>Clock Time Offset</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_CLOCK</property>
</properties>
</channel>
</channels>
<!-- DEVICE PROPERTY DEFINITIONS -->
<properties>
<property name="vendor">Building 36 Technologies</property>
<property name="modelId">ADC-T3000</property>
<property name="manufacturerId">0190</property>
<property name="manufacturerRef">0006:0001</property>
<property name="dbReference">1248</property>
<property name="defaultAssociations">1</property>
</properties>
<!-- CONFIGURATION DESCRIPTIONS -->
<config-description>
<!-- GROUP DEFINITIONS -->
<parameter-group name="association">
<context>link</context>
<label>Association Groups</label>
</parameter-group>
<!-- ASSOCIATION DEFINITIONS -->
<parameter name="group_1" type="text" groupName="association" multiple="true">
<label>1: Lifeline</label>
<multipleLimit>4</multipleLimit>
</parameter>
<!-- STATIC DEFINITIONS -->
<parameter name="node_id" type="integer" min="1" max="232" readOnly="true" required="true">
<label>Node ID</label>
<advanced>true</advanced>
</parameter>
</config-description>
</thing-type>
<channel-type id="building36_adct3000_00_000_thermostat_mode">
<item-type>Number</item-type>
<label>Thermostat Mode</label>
<description>Sets the thermostat mode</description>
<category>Temperature</category>
<state pattern="%s">
<options>
<option value="0">Off</option>
<option value="1">Heat</option>
</options>
</state>
</channel-type>
<channel-type id="building36_adct3000_00_000_thermostat_fanmode">
<item-type>Number</item-type>
<label>Thermostat Fan Mode</label>
<description>Sets the thermostat fan mode</description>
<category>Temperature</category>
<state pattern="%s">
<options>
<option value="0">Auto (Low)</option>
<option value="1">On (Low)</option>
<option value="6">Circulate</option>
</options>
</state>
</channel-type>
<channel-type id="building36_adct3000_00_000_thermostat_fanstate">
<item-type>Number</item-type>
<label>Thermostat Fan State</label>
<description>Sets the thermostat fan state</description>
<category>Temperature</category>
<state pattern="%s">
<options>
<option value="0">Idle</option>
</options>
</state>
</channel-type>
</thing:thing-descriptions>

View File

@ -1,129 +0,0 @@
<?xml version="1.0" encoding="UTF-8"?>
<thing:thing-descriptions bindingId="zwave"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0
https://openhab.org/schemas/thing-description/v1.0.0">
<thing-type id="ge_58433_00_000" listed="false">
<label>GE 58433 GE Enbrighten Z-Wave Plus Smart Switch</label>
<description><![CDATA[
GE Enbrighten Z-Wave Plus Smart Switch<br /> <h1>Overview</h1><p>Home automation is even smarter with the Enbrighten Z-Wave In-Wall Smart Switch with QuickFit™ and SimpleWire™. When paired with a compatible hub, the hardwired smart switch operates wall, ceiling and accent lighting through individual commands and programmed settings. Wirelessly control and schedule indoor or outdoor fixtures for effortless management of your home. Your automation possibilities are seemingly infinite when connected to hubs from Ring, Wink, SmartThings, HomeSeer, Vera, American Standard and more.</p><p>Home automation is even smarter with the GE Enbrighten Z-Wave Plus In-Wall Smart Switch with QuickFit™ and SimpleWire™. When paired with a compatible hub, the hardwired smart switch operates wall, ceiling and accent lighting through individual commands and programmed settings. Wirelessly control and schedule indoor or outdoor fixtures for effortless management of your home. Your automation possibilities are seemingly infinite when connected to hubs from Ring, Wink, SmartThings, HomeSeer, Vera, Nexia and more.</p> <br /> <h2>Inclusion Information</h2><p> Once the controller is ready to include your device, press up and release on the toggle to include it in the network. </p><p> Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. </p><ol><li>Once the controller is ready to include your device, press up and release on the toggle to include it in the network. </li> <li>Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. </li> </ol> <br /> <h2>Exclusion Information</h2><p>Once the controller is ready to exclude your device, press up and release on the toggle to exclude it from the network. </p><ol><li>Once the controller is ready to include your device, press up and release on the toggle to include it in the network. </li> <li>Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance. </li> </ol> <br /> <h2>Wakeup Information</h2><p><br /></p>
]]></description>
<category>WallSwitch</category>
<!-- CHANNEL DEFINITIONS -->
<channels>
<channel id="switch_binary" typeId="switch_binary">
<label>Switch</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_SWITCH_BINARY</property>
</properties>
</channel>
<channel id="scene_number" typeId="scene_number">
<label>Scene Number</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_SCENE_ACTIVATION</property>
</properties>
</channel>
<channel id="scene_number" typeId="scene_number">
<label>Scene Number</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_CENTRAL_SCENE</property>
</properties>
</channel>
</channels>
<!-- DEVICE PROPERTY DEFINITIONS -->
<properties>
<property name="vendor">Jasco Products</property>
<property name="modelId">GE 58433</property>
<property name="manufacturerId">0063</property>
<property name="manufacturerRef">4952:3239</property>
<property name="dbReference">1589</property>
<property name="defaultAssociations">1</property>
</properties>
<!-- CONFIGURATION DESCRIPTIONS -->
<config-description>
<!-- GROUP DEFINITIONS -->
<parameter-group name="configuration">
<context>setup</context>
<label>Configuration Parameters</label>
</parameter-group>
<parameter-group name="association">
<context>link</context>
<label>Association Groups</label>
</parameter-group>
<!-- PARAMETER DEFINITIONS -->
<parameter name="config_3_1" type="integer" groupName="configuration">
<label>3: LED Mode</label>
<description><![CDATA[
LED Indication Configuration<br /> <h1>Overview</h1><p>Sets mode for LED inside toggle switch</p>
]]></description>
<default>2</default>
<options>
<option value="0">LED ON when switch is OFF</option>
<option value="1">LED ON when switch is ON</option>
<option value="2">LED always OFF</option>
<option value="3">LED Always ON</option>
</options>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_4_1" type="integer" groupName="configuration">
<label>4: Invert Switch</label>
<description><![CDATA[
Invert Switch<br /> <h1>Overview</h1><p>If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4s value to “1”.</p>
]]></description>
<default>0</default>
<options>
<option value="0">Normal Switch Install</option>
<option value="1">Inverted Switch Install</option>
</options>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_19_1" type="integer" groupName="configuration">
<label>19: Alternate Exclusion</label>
<description>Set Alternate Exclusion Mode</description>
<default>0</default>
<options>
<option value="0">Press any button on the switch</option>
<option value="1">Alternate Exclusion</option>
</options>
<limitToOptions>false</limitToOptions>
</parameter>
<!-- ASSOCIATION DEFINITIONS -->
<parameter name="group_1" type="text" groupName="association" multiple="true">
<label>1: Lifeline</label>
<description>Lifeline</description>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_2" type="text" groupName="association" multiple="true">
<label>2: Group 2</label>
<description>Basic Set single click</description>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_3" type="text" groupName="association" multiple="true">
<label>3: Basic Set double click</label>
<multipleLimit>5</multipleLimit>
</parameter>
<!-- STATIC DEFINITIONS -->
<parameter name="node_id" type="integer" min="1" max="232" readOnly="true" required="true">
<label>Node ID</label>
<advanced>true</advanced>
</parameter>
</config-description>
</thing-type>
</thing:thing-descriptions>

View File

@ -1,110 +0,0 @@
<?xml version="1.0" encoding="UTF-8"?>
<thing:thing-descriptions bindingId="zwave"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0
https://openhab.org/schemas/thing-description/v1.0.0">
<thing-type id="keemple_wallplug_04_000" listed="false">
<label>Keemple KP-SO-02 Wall Plug Switch</label>
<description><![CDATA[
Wall Plug Switch<br /> <h1>Overview</h1><p>This Plug provides line voltage, current load, power consumption and energy consumption measuring. </p><p>Voltage The Supply Power Voltage For Plug.</p><p>Current The Current for the Electric Device Connect to Plug Consumption.</p><p>Power Power Consumed by an Electric Device in an instant, unit: Watt (W).</p><p>Energy Energy Consumed by an Electric Device through a Time Period. Most commonly measured in Kilowatt-hours (kWh). One kilowatt-hour is Equal to One Kilowatt of Power Consumed over a Period of One Hour, 1kWh = 1000Wh.0Wh.</p> <br /> <h2>Inclusion Information</h2><ol><li>Connect a plug to power and wait at least 20 seconds.</li><li>Set ZWave controller or ZWave gateway into inclusion mode (refer to the controller or gateway operating manual).</li><li>Briefly press the plug button three times (the LED will alternately flash gree five times).</li></ol> <br /> <h2>Exclusion Information</h2><ol><li>Connect a plug to power and wait at least 20 seconds.</li><li>et ZWave controller or ZWave gateway into exclusion mode (refer to the controller or gateway operating manual).</li><li>Briefly press the plug button three times (the LED will alternately flash pink five times).</li></ol> <br /> <h2>Wakeup Information</h2><p><br /></p>
]]></description>
<category>WallSwitch</category>
<!-- CHANNEL DEFINITIONS -->
<channels>
<channel id="switch_binary" typeId="switch_binary">
<label>Switch</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_SWITCH_BINARY</property>
</properties>
</channel>
<channel id="meter_watts" typeId="meter_watts">
<label>Electric meter (watts)</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_METER;type=E_W</property>
</properties>
</channel>
<channel id="meter_kwh" typeId="meter_kwh">
<label>Electric meter (kWh)</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_METER;type=E_KWh</property>
</properties>
</channel>
<channel id="meter_voltage" typeId="meter_voltage">
<label>Electric meter (volts)</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_METER;type=E_V</property>
</properties>
</channel>
<channel id="meter_current" typeId="meter_current">
<label>Electric meter (amps)</label>
<properties>
<property name="binding:*:DecimalType">COMMAND_CLASS_METER;type=E_A</property>
</properties>
</channel>
<channel id="alarm_power" typeId="alarm_power">
<label>Alarm (power)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=POWER_MANAGEMENT</property>
</properties>
</channel>
</channels>
<!-- DEVICE PROPERTY DEFINITIONS -->
<properties>
<property name="vendor">Keemplecom Limited</property>
<property name="modelId">Keemple KP-SO-02</property>
<property name="manufacturerId">041A</property>
<property name="manufacturerRef">0200:0008</property>
<property name="versionMin">4.0</property>
<property name="dbReference">1359</property>
<property name="defaultAssociations">1</property>
</properties>
<!-- CONFIGURATION DESCRIPTIONS -->
<config-description>
<!-- GROUP DEFINITIONS -->
<parameter-group name="association">
<context>link</context>
<label>Association Groups</label>
</parameter-group>
<!-- ASSOCIATION DEFINITIONS -->
<parameter name="group_1" type="text" groupName="association" multiple="true">
<label>1: Lifeline</label>
<description><![CDATA[
Assigned to Plugs status - On/Off. Allows for receiving control command from trigger devices whenever the Plug is turned On or Off.<br /> <h1>Overview</h1><p>NOTIFICATION_REPORT_V4</p><p>METER_REPORT_V4</p><p>SWITCH_BINARY_REPORT</p><p>DEVICE_RESET_LOCALLY_NOTIFICATION</p>
]]></description>
<multipleLimit>1</multipleLimit>
</parameter>
<parameter name="group_2" type="text" groupName="association" multiple="true">
<label>2: Group 2</label>
<description><![CDATA[
Sending control commands to associated devices. If current load is over the max current defined in parameter #3, the Plug will send a BASIC_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC_SET (0x00).<br /> <h1>Overview</h1><p>BASIC_SET<br /></p>
]]></description>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_3" type="text" groupName="association" multiple="true">
<label>3: Group 3</label>
<description><![CDATA[
Send Notification to associated devices.<br /> <h1>Overview</h1><p>NOTIFICATION_REPORT_V4<br /></p>
]]></description>
<multipleLimit>5</multipleLimit>
</parameter>
<!-- STATIC DEFINITIONS -->
<parameter name="node_id" type="integer" min="1" max="232" readOnly="true" required="true">
<label>Node ID</label>
<advanced>true</advanced>
</parameter>
</config-description>
</thing-type>
</thing:thing-descriptions>

View File

@ -5,10 +5,10 @@
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0
https://openhab.org/schemas/thing-description/v1.0.0">
<thing-type id="zooz_zen51_00_000" listed="false">
<label>ZEN51 Dry Contact Relay</label>
<thing-type id="zooz_zen51lr_01_050" listed="false">
<label>ZEN51 LR Dry Contact Relay</label>
<description><![CDATA[
Dry Contact Relay<br /> <h1>Overview</h1><p>On/off Z-Wave control for 120V and dry contact applications: great for lighting control or 120V load monitoring (sump pumps, motion lights)</p><p>700 series Z-Wave chip: greater coverage for a stronger mesh network</p><p>SmartStart and S2 authenticated security for a truly protected smart home</p><p>Installs behind the existing wall switch or at the fixture (if neutral is not available in the switch box)</p> <br /> <h2>Inclusion Information</h2><ol><li>Initiate inclusion (pairing) in the app (or web interface).</li><li>Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.</li><li>The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.</li></ol> <br /> <h2>Exclusion Information</h2><ol><li>Bring your Z-Wave gateway (hub) close to the relay if possible</li><li>Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)</li><li>Click the on the relay 3 times quickly (theZ-Wave button LED indicator will start blinking green)</li><li>Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list.</li></ol> <br /> <h2>Wakeup Information</h2><p><br /></p>
Dry Contact Relay<br /> <h1>Overview</h1><p>On/off Z-Wave control for 120V and dry contact applications: great for lighting control or 120V load monitoring (sump pumps, motion lights)</p><p>700 series Z-Wave chip: greater coverage for a stronger mesh network</p><p>SmartStart and S2 authenticated security for a truly protected smart home</p><p>Installs behind the existing wall switch or at the fixture (if neutral is not available in the switch box)</p><p>On/off Z-Wave control for 120V and dry contact applications: great for lighting control or 120V load monitoring (sump pumps, motion lights)</p><p>700 series Z-Wave chip: greater coverage for a stronger mesh network</p><p>SmartStart and S2 authenticated security for a truly protected smart home</p><p>Installs behind the existing wall switch or at the fixture (if neutral is not available in the switch box)</p> <br /> <h2>Inclusion Information</h2><ol><li> Initiate inclusion (pairing) in the app (or web interface).</li><li> Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.</li><li> The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.</li></ol><ol><li>Initiate inclusion (pairing) in the app (or web interface).</li><li>Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.</li><li>The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.</li></ol> <br /> <h2>Exclusion Information</h2><ol><li> Bring your Z-Wave gateway (hub) close to the relay if possible</li><li> Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)</li><li> Click the on the relay 3 times quickly (theZ-Wave button LED indicator will start blinking green)</li><li> Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list.</li></ol><ol><li>Initiate inclusion (pairing) in the app (or web interface).</li><li>Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.</li><li>The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.</li></ol> <br /> <h2>Wakeup Information</h2><p><br /></p><p><br /></p>
]]></description>
<category>WallSwitch</category>
@ -31,10 +31,11 @@ Dry Contact Relay<br /> <h1>Overview</h1><p>On/off Z-Wave control for 120V and d
<!-- DEVICE PROPERTY DEFINITIONS -->
<properties>
<property name="vendor">Zooz</property>
<property name="modelId">ZEN51</property>
<property name="modelId">ZEN51 LR</property>
<property name="manufacturerId">027A</property>
<property name="manufacturerRef">0104:0201</property>
<property name="dbReference">1486</property>
<property name="manufacturerRef">0904:0201</property>
<property name="versionMin">1.50</property>
<property name="dbReference">1592</property>
<property name="defaultAssociations">1</property>
</properties>
@ -191,6 +192,18 @@ Duration of the impulse if using the relay with 3-way impulse control<br /> <h1>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_12_1" type="integer" groupName="configuration">
<label>12: External Switch Multiple Click Detection</label>
<description><![CDATA[
Enable or disable the external switch multiple click detection.<br /> <h1>Overview</h1><p>0 disable the external switch multiple click detection. Clicking the external switch 3 times quickly for inclusion/exclusion will be disabled, and the central scene actions (multi-tap) will be disabled. </p><p>1 Enable the external switch multiple click detection (default).</p>
]]></description>
<default>1</default>
<options>
<option value="0">Disable the external switch multiple click detection</option>
<option value="1">Enable the external switch multiple click detection (default)</option>
</options>
</parameter>
<!-- ASSOCIATION DEFINITIONS -->
<parameter name="group_1" type="text" groupName="association" multiple="true">
<label>1: Group 1; Lifeline communication</label>

View File

@ -0,0 +1,196 @@
<?xml version="1.0" encoding="UTF-8"?>
<thing:thing-descriptions bindingId="zwave"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:thing="https://openhab.org/schemas/thing-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/thing-description/v1.0.0
https://openhab.org/schemas/thing-description/v1.0.0">
<thing-type id="zooz_zen55lr_00_000" listed="false">
<label>ZEN55 LR DC Signal Sensor (Smoke and CO Detector Bridge)</label>
<description><![CDATA[
DC Signal Sensor (Smoke and CO Detector Bridge)<br /> <h1>Overview</h1><ul><li>Z-Wave alerts from low-voltage trigger signals</li><li>Connect to smoke or CO detectors to monitor activity</li><li>120 V relay to control a security siren or lights</li><li>Installs in the box with the last smoke detector in series</li><li>800 series Z-Wave chip for better range and faster control</li><li>Z-Wave Long Range for ultra reliable no-mesh communication</li><li>Advanced settings to customize the devices behavior</li><li>Built-in Z-Wave signal repeater for boosted communication</li><li>SmartStart and S2 Authenticate Security for a safer network</li></ul> <br /> <h2>Inclusion Information</h2><ol><li> Initiate inclusion (pairing) in the app (or web interface).</li><li> Tap the Z-WAVE button 3 times quickly if using traditional Z-Wave inclusion.</li><li> The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails.</li></ol> <br /> <h2>Exclusion Information</h2><ol><li> Bring your Z-Wave gateway (hub) close to the relay if possible</li><li> Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)</li><li> Click the on the relay 3 times quickly (the Z-Wave button LED indicator will start blinking green)</li><li> Your hub will confirm exclusion, the LED indicator on the relay will turn green for 2 seconds, and the device will disappear from your controller's device list.</li></ol> <br /> <h2>Wakeup Information</h2><p><br /></p>
]]></description>
<category>Sensor</category>
<!-- CHANNEL DEFINITIONS -->
<channels>
<channel id="alarm_smoke" typeId="alarm_smoke">
<label>Alarm (smoke)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=SMOKE</property>
</properties>
</channel>
<channel id="alarm_co" typeId="alarm_co">
<label>Alarm (CO)</label>
<properties>
<property name="binding:*:OnOffType">COMMAND_CLASS_ALARM;type=CARBON_MONOXIDE</property>
</properties>
</channel>
</channels>
<!-- DEVICE PROPERTY DEFINITIONS -->
<properties>
<property name="vendor">Zooz</property>
<property name="modelId">ZEN55 LR</property>
<property name="manufacturerId">027A</property>
<property name="manufacturerRef">0004:0110</property>
<property name="dbReference">1593</property>
<property name="defaultAssociations">1</property>
</properties>
<!-- CONFIGURATION DESCRIPTIONS -->
<config-description>
<!-- GROUP DEFINITIONS -->
<parameter-group name="configuration">
<context>setup</context>
<label>Configuration Parameters</label>
</parameter-group>
<parameter-group name="association">
<context>link</context>
<label>Association Groups</label>
</parameter-group>
<!-- PARAMETER DEFINITIONS -->
<parameter name="config_1_1" type="integer" groupName="configuration">
<label>1: LED Indicator</label>
<description>Enable or disable the LED indicator to reflect the current on/off status of the connected load (LED on when the load is on, LED off when the load is off).</description>
<default>1</default>
<options>
<option value="0">LED Indicator disabled</option>
<option value="1">LED Indicator enabled (default)</option>
</options>
</parameter>
<parameter name="config_2_1" type="integer" groupName="configuration">
<label>2: Relay Alarm Trigger</label>
<description>Use this parameter to automatically trigger the relay to turn the connected load on when alarm is detected on the input (signal) side.</description>
<default>1</default>
<options>
<option value="0">auto-trigger disabled</option>
<option value="1">auto-trigger enabled (default)</option>
</options>
</parameter>
<parameter name="config_3_4" type="integer" groupName="configuration">
<label>3: Auto Turn-Off Timer</label>
<description><![CDATA[
Use this parameter to set the time after which you want the device connected to the relay to automatically turn off once it has been turned on. The number entered as value corresponds to the number of seconds.<br /> <h1>Overview</h1><p>0 timer disabled (default); 1 4294967295<br /></p>
]]></description>
<default>0</default>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_4_4" type="integer" groupName="configuration">
<label>4: Auto Turn-Off Timer</label>
<description><![CDATA[
Use this parameter to set the time after which you want the device connected to the relay to automatically turn on once it has been turned off. The number entered as value corresponds to the number of seconds.<br /> <h1>Overview</h1><p>0 timer disabled (default); 1 4294967295</p>
]]></description>
<default>0</default>
<limitToOptions>false</limitToOptions>
</parameter>
<parameter name="config_5_1" type="integer" groupName="configuration">
<label>5: On/Off Status After Power Failure</label>
<description>Set the on/off status for the relay after power failure</description>
<default>2</default>
<options>
<option value="0">forced to OFF (regardless of state prior to power outage)</option>
<option value="1">forced to ON (regardless of state prior to power outage)</option>
<option value="2">remembers and restores on/off status after power failure (default)</option>
</options>
</parameter>
<parameter name="config_6_1" type="integer" groupName="configuration">
<label>6: Association Reports (Group 2) - Smoke Alarm</label>
<description>Decide when the device will send BASIC_SET commands to devices associated in Group 2 (Smoke Alarm).</description>
<default>0</default>
<options>
<option value="0">BASIC_SET (0xFF) ON when smoke is detected, BASIC_SET (0x00) OFF when</option>
<option value="1">BASIC_SET (0x00) OFF when smoke is detected, BASIC_SET (0xFF) ON when</option>
<option value="2">BASIC_SET (0xFF) ON when smoke is detected, no commands sent when smok</option>
<option value="3">BASIC_SET (0x00) OFF when smoke is detected, no commands sent when smo</option>
<option value="4">BASIC_SET (0x00) OFF when smoke is not detected, no commands sent when</option>
<option value="5">BASIC_SET (0xFF) ON when smoke is not detected, no commands sent when</option>
</options>
</parameter>
<parameter name="config_7_1" type="integer" groupName="configuration">
<label>7: Association Reports (Group 3) - CO Alarm</label>
<description>Decide when the device will send BASIC_SET commands to devices associated in Group 3 (CO Alarm).</description>
<default>0</default>
<options>
<option value="0">BASIC_SET (0xFF) ON when CO is detected, BASIC_SET (0x00) OFF when CO</option>
<option value="1">BASIC_SET (0x00) OFF when CO is detected, BASIC_SET (0xFF) ON when CO</option>
<option value="2">BASIC_SET (0xFF) ON when CO is detected, no commands sent when CO is n</option>
<option value="3">BASIC_SET (0x00) OFF when CO is detected, no commands sent when CO is</option>
<option value="4">BASIC_SET (0x00) OFF when CO is not detected, no commands sent when CO</option>
<option value="5">BASIC_SET (0xFF) ON when CO is not detected, no commands sent when CO</option>
</options>
</parameter>
<parameter name="config_8_1" type="integer" groupName="configuration">
<label>8: Disable the Sensors or Relay</label>
<description><![CDATA[
After changing this parameter and re-inclusion, the device will show up as a switch, which can be controlled via Z-Wave.<br /> <h1>Overview</h1><p>NOTE: You need to exclude and re-include the device to your hub or re-configure (re-interview) the device if the value of this setting is changed.</p>
]]></description>
<default>1</default>
<options>
<option value="1">Enable smoke and CO sensor endpoints and disable the relay switch endp</option>
<option value="2">Enable the CO sensor endpoint and disable the smoke sensor and relay e</option>
<option value="3">Enable the smoke sensor endpoint and disable the CO sensor and relay e</option>
<option value="4">Enable the smoke sensor, CO sensor, and the relay endpoints (all endpo</option>
<option value="5">Enable the relay and CO sensor endpoints and disable the smoke sensor</option>
<option value="6">Enable the relay and smoke sensor endpoints and disable the CO sensor</option>
<option value="7">Enable the relay endpoint and disable the CO sensor and smoke sensor e</option>
</options>
</parameter>
<parameter name="config_9_1" type="integer" groupName="configuration">
<label>9: Relay Status Reports</label>
<description>Decide what type of reports the relay part of the device sends back to the hub when it changes status.</description>
<default>0</default>
<options>
<option value="0">binary switch report for Z-Wave control and input control (from the DC</option>
<option value="1">binary switch report for Z-Wave control and basic report for input con</option>
<option value="2">basic report for Z-Wave control and input control (from the DC signal</option>
</options>
</parameter>
<!-- ASSOCIATION DEFINITIONS -->
<parameter name="group_1" type="text" groupName="association" multiple="true">
<label>1: Group 1 - Lifeline</label>
<description>Send BASIC REPORT and NOTIFICATION REPORT to Group 1</description>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_2" type="text" groupName="association" multiple="true">
<label>2: Group 2 - Smoke Alarm</label>
<description>Send BASIC SET command</description>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_3" type="text" groupName="association" multiple="true">
<label>3: Group 3 - CO Alarm</label>
<description>Send BASIC SET command</description>
<multipleLimit>5</multipleLimit>
</parameter>
<parameter name="group_4" type="text" groupName="association" multiple="true">
<label>4: Group 4</label>
<description>Send BASIC SET command</description>
<multipleLimit>5</multipleLimit>
</parameter>
<!-- STATIC DEFINITIONS -->
<parameter name="node_id" type="integer" min="1" max="232" readOnly="true" required="true">
<label>Node ID</label>
<advanced>true</advanced>
</parameter>
</config-description>
</thing-type>
</thing:thing-descriptions>