[tacmi] Add JSON API documentation
Add documentation on how to use the JSON API. Signed-off-by: Moritz 'Morty' Strübe <morty@gmx.net>pull/14119/head
parent
9f661c0d75
commit
85394e9a2c
|
@ -18,6 +18,11 @@ CoE (CAN over Ethernet) Connection
|
||||||
- Send ON/OFF to digital CAN-inputs defined in TAPPS2
|
- Send ON/OFF to digital CAN-inputs defined in TAPPS2
|
||||||
- Send numeric values to analog CAN-inputs defined in TAPPS2
|
- Send numeric values to analog CAN-inputs defined in TAPPS2
|
||||||
|
|
||||||
|
JSON API
|
||||||
|
|
||||||
|
- Read selected data via the JSON API (inputs, outputs, logging).
|
||||||
|
See [API documentation](https://wiki.ta.co.at/C.M.I._JSON-API) for details
|
||||||
|
|
||||||
Depending on what you want to achieve, either the "Schema API Page" or the CoE way might be better.
|
Depending on what you want to achieve, either the "Schema API Page" or the CoE way might be better.
|
||||||
As rough guidance: Anything you want to provide to the TA equipment it has to work / operate with the CoE might be better.
|
As rough guidance: Anything you want to provide to the TA equipment it has to work / operate with the CoE might be better.
|
||||||
If you plan things mainly for user interaction the "Schema API Page" might be better.
|
If you plan things mainly for user interaction the "Schema API Page" might be better.
|
||||||
|
@ -25,22 +30,23 @@ If you plan things mainly for user interaction the "Schema API Page" might be be
|
||||||
## Supported Bridge and Things
|
## Supported Bridge and Things
|
||||||
|
|
||||||
- TA C.M.I. **Schema API Connection** - Thing \
|
- TA C.M.I. **Schema API Connection** - Thing \
|
||||||
This thing reflecting one of our 'schema API page' as defined in the prerequisites.
|
This thing reflecting one of our 'schema API page' as defined in the prerequisites.
|
||||||
This thing doesn't need the bridge.
|
This thing doesn't need the bridge.
|
||||||
Multiple of these pages on different C.M.I.'s could be defined within an openHAB instance.
|
Multiple of these pages on different C.M.I.'s could be defined within an openHAB instance.
|
||||||
|
|
||||||
- TA C.M.I. **CoE Bridge** \
|
- TA C.M.I. **CoE Bridge** \
|
||||||
In order to get the CAN over Ethernet (COE) envionment working a `coe-bridge` has to be created.
|
In order to get the CAN over Ethernet (COE) envionment working a `coe-bridge` has to be created.
|
||||||
The bridge itself opens the UDP port 5441 for communication with the C.M.I. devices.
|
The bridge itself opens the UDP port 5441 for communication with the C.M.I. devices.
|
||||||
The bridge could be used for multiple C.M.I. devices.
|
The bridge could be used for multiple C.M.I. devices.
|
||||||
|
|
||||||
- TA C.M.I. **CoE Connection** - Thing \
|
- TA C.M.I. **CoE Connection** - Thing \
|
||||||
This thing reflects a connection to a node behind a specific C.M.I..
|
This thing reflects a connection to a node behind a specific C.M.I..
|
||||||
This node could be every CAN-Capable device from TA which allows to define a CAN-Input.
|
This node could be every CAN-Capable device from TA which allows to define a CAN-Input.
|
||||||
|
- TA C.M.I. **JSON API Connection** - Thing \
|
||||||
|
This is a thing connection that regularly polls the CMI using the JSON API.
|
||||||
|
|
||||||
## Discovery
|
## Discovery
|
||||||
|
|
||||||
Autodiscovering is not supported. We have to define the things manually.
|
Autodiscovering is not supported.
|
||||||
|
You have to define the things manually.
|
||||||
|
|
||||||
## Schema API
|
## Schema API
|
||||||
|
|
||||||
|
@ -271,4 +277,20 @@ sitemap heatingTA label="heatingTA"
|
||||||
}
|
}
|
||||||
```
|
```
|
||||||
|
|
||||||
|
## JSON API
|
||||||
|
|
||||||
|
Before setting up the JSON API, it is worth reading the [API documention](https://wiki.ta.co.at/C.M.I._JSON-API).
|
||||||
|
Once configured, the exposed items should show up as channels.
|
||||||
|
|
||||||
|
### Configuring the JSON API
|
||||||
|
|
||||||
|
The _TA C.M.I. JSON API Connection_ has to be manually configured.
|
||||||
|
|
||||||
|
| Parameter Label | Parameter ID | Description | Accepted values |
|
||||||
|
| ----------------- | ------------ | ------------------------------------------------------------------------------- | ----------------------------- |
|
||||||
|
| C.M.I. IP Address | host | Host name or IP address of the C.M.I. | Any String |
|
||||||
|
| User name | username | User name for authentication on the C.M.I. | Any String |
|
||||||
|
| Password | password | Password for authentication on the C.M.I. | Any String |
|
||||||
|
| Node Id | nodeId | The node ID of the device you want to monitor (CMI → CAN-Bus) | An Integer that is not 0 |
|
||||||
|
| API-Parameters | params | The params to query. E.g. I,O,Sg (See the [API documentation](https://wiki.ta.co.at/C.M.I._JSON-API) for details) <br/> Possible options are: Inputs (I), Outputs (O), General (Sg), Logging Analog (La), Logging Digital (Ld) | Any String |
|
||||||
|
| Poll Interval | pollInterval | Poll interval in seconds. The documentation suggests 60s, but less is possible. | An integer between 10 and 900 |
|
||||||
|
|