Fix/update channels for setting hot water target temperature (#11135)
Signed-off-by: Stefan Giehl <stefangiehl@gmail.com>pull/11145/head
parent
b6aa401cf9
commit
5f6d9b91ef
|
@ -162,6 +162,7 @@ public class LuxtronikHeatpumpHandler extends BaseThingHandler {
|
||||||
case CHANNEL_EINST_BWS_AKT:
|
case CHANNEL_EINST_BWS_AKT:
|
||||||
case CHANNEL_EINST_KUCFTL_AKT:
|
case CHANNEL_EINST_KUCFTL_AKT:
|
||||||
case CHANNEL_SOLLWERT_KUCFTL_AKT:
|
case CHANNEL_SOLLWERT_KUCFTL_AKT:
|
||||||
|
case CHANNEL_SOLL_BWS_AKT:
|
||||||
float temperature = ((DecimalType) command).floatValue();
|
float temperature = ((DecimalType) command).floatValue();
|
||||||
value = (int) (temperature * 10);
|
value = (int) (temperature * 10);
|
||||||
break;
|
break;
|
||||||
|
|
|
@ -1204,10 +1204,10 @@ public enum HeatpumpChannel {
|
||||||
HeatpumpVisibility.HEIZUNG),
|
HeatpumpVisibility.HEIZUNG),
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* Hot water temperature
|
* Coverage Heat pump (Hot Water)
|
||||||
* (original: Warmwasser Soll Temperatur)
|
* (original: Deckung Wärmepumpe)
|
||||||
*/
|
*/
|
||||||
CHANNEL_EINST_BWS_AKT(2, "temperatureHotWaterTarget", NumberItem.class, SIUnits.CELSIUS, true,
|
CHANNEL_EINST_BWS_AKT(2, "temperatureHotWaterCoverage", NumberItem.class, SIUnits.CELSIUS, true,
|
||||||
HeatpumpVisibility.BRAUWASSER),
|
HeatpumpVisibility.BRAUWASSER),
|
||||||
|
|
||||||
/**
|
/**
|
||||||
|
@ -1271,6 +1271,13 @@ public enum HeatpumpChannel {
|
||||||
CHANNEL_EINST_BWTDI_AKT_AL(27, "thermalDisinfectionPermanent", SwitchItem.class, null, true,
|
CHANNEL_EINST_BWTDI_AKT_AL(27, "thermalDisinfectionPermanent", SwitchItem.class, null, true,
|
||||||
HeatpumpVisibility.THERMDESINFEKT),
|
HeatpumpVisibility.THERMDESINFEKT),
|
||||||
|
|
||||||
|
/**
|
||||||
|
* Hot water target temperature
|
||||||
|
* (original: Warmwasser Soll Temperatur)
|
||||||
|
*/
|
||||||
|
CHANNEL_SOLL_BWS_AKT(105, "temperatureHotWaterTarget", NumberItem.class, SIUnits.CELSIUS, true,
|
||||||
|
HeatpumpVisibility.BRAUWASSER),
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* Comfort cooling mode
|
* Comfort cooling mode
|
||||||
* (original: Comfort Kühlung Betriebsart)
|
* (original: Comfort Kühlung Betriebsart)
|
||||||
|
|
|
@ -26,6 +26,7 @@ channel-type.luxtronikheatpump.temperatureOutside.label = Außentemp.
|
||||||
channel-type.luxtronikheatpump.temperatureOutsideMean.label = Durchschnittstemp. Außen über 24 h (Funktion Heizgrenze)
|
channel-type.luxtronikheatpump.temperatureOutsideMean.label = Durchschnittstemp. Außen über 24 h (Funktion Heizgrenze)
|
||||||
channel-type.luxtronikheatpump.temperatureHotWater.label = Warmwasser Ist-Temp.
|
channel-type.luxtronikheatpump.temperatureHotWater.label = Warmwasser Ist-Temp.
|
||||||
channel-type.luxtronikheatpump.temperatureHotWaterTarget.label = Warmwasser Soll-Temp.
|
channel-type.luxtronikheatpump.temperatureHotWaterTarget.label = Warmwasser Soll-Temp.
|
||||||
|
channel-type.luxtronikheatpump.temperatureHotWaterCoverage.label = Warmwasser Deckung WP
|
||||||
channel-type.luxtronikheatpump.temperatureHeatSourceInlet.label = Wärmequellen-Eintrittstemp.
|
channel-type.luxtronikheatpump.temperatureHeatSourceInlet.label = Wärmequellen-Eintrittstemp.
|
||||||
channel-type.luxtronikheatpump.temperatureHeatSourceOutlet.label = Wärmequellen-Austrittstemp.
|
channel-type.luxtronikheatpump.temperatureHeatSourceOutlet.label = Wärmequellen-Austrittstemp.
|
||||||
channel-type.luxtronikheatpump.temperatureMixingCircuit1Flow.label = Mischkreis 1 Vorlauftemp.
|
channel-type.luxtronikheatpump.temperatureMixingCircuit1Flow.label = Mischkreis 1 Vorlauftemp.
|
||||||
|
|
|
@ -1954,9 +1954,9 @@
|
||||||
<state pattern="%.1f %unit%" min="-10" max="10" step="0.5"></state>
|
<state pattern="%.1f %unit%" min="-10" max="10" step="0.5"></state>
|
||||||
</channel-type>
|
</channel-type>
|
||||||
|
|
||||||
<channel-type id="temperatureHotWaterTarget">
|
<channel-type id="temperatureHotWaterCoverage">
|
||||||
<item-type>Number:Temperature</item-type>
|
<item-type>Number:Temperature</item-type>
|
||||||
<label>Hot Water Target Temp.</label>
|
<label>Coverage Hot Water Temp.</label>
|
||||||
<category>Temperature</category>
|
<category>Temperature</category>
|
||||||
<state pattern="%.1f %unit%" min="30" max="65" step="0.5"></state>
|
<state pattern="%.1f %unit%" min="30" max="65" step="0.5"></state>
|
||||||
</channel-type>
|
</channel-type>
|
||||||
|
@ -2029,6 +2029,13 @@
|
||||||
<label>Thermal Disinfection (Permanent)</label>
|
<label>Thermal Disinfection (Permanent)</label>
|
||||||
</channel-type>
|
</channel-type>
|
||||||
|
|
||||||
|
<channel-type id="temperatureHotWaterTarget">
|
||||||
|
<item-type>Number:Temperature</item-type>
|
||||||
|
<label>Hot Water Target Temp.</label>
|
||||||
|
<category>Temperature</category>
|
||||||
|
<state pattern="%.1f %unit%" min="30" max="65" step="0.5"></state>
|
||||||
|
</channel-type>
|
||||||
|
|
||||||
<channel-type id="comfortCoolingMode">
|
<channel-type id="comfortCoolingMode">
|
||||||
<item-type>Number</item-type>
|
<item-type>Number</item-type>
|
||||||
<label>Comfort Cooling Mode</label>
|
<label>Comfort Cooling Mode</label>
|
||||||
|
|
|
@ -16,6 +16,7 @@
|
||||||
<channel id="temperatureOutsideMean" typeId="temperatureOutsideMean"/>
|
<channel id="temperatureOutsideMean" typeId="temperatureOutsideMean"/>
|
||||||
<channel id="temperatureHotWater" typeId="temperatureHotWater"/>
|
<channel id="temperatureHotWater" typeId="temperatureHotWater"/>
|
||||||
<channel id="temperatureHotWaterTarget" typeId="temperatureHotWaterTarget"/>
|
<channel id="temperatureHotWaterTarget" typeId="temperatureHotWaterTarget"/>
|
||||||
|
<channel id="temperatureHotWaterCoverage" typeId="temperatureHotWaterCoverage"/>
|
||||||
<channel id="temperatureHeatSourceInlet" typeId="temperatureHeatSourceInlet"/>
|
<channel id="temperatureHeatSourceInlet" typeId="temperatureHeatSourceInlet"/>
|
||||||
<channel id="temperatureHeatSourceOutlet" typeId="temperatureHeatSourceOutlet"/>
|
<channel id="temperatureHeatSourceOutlet" typeId="temperatureHeatSourceOutlet"/>
|
||||||
<channel id="temperatureMixingCircuit1Flow" typeId="temperatureMixingCircuit1Flow"/>
|
<channel id="temperatureMixingCircuit1Flow" typeId="temperatureMixingCircuit1Flow"/>
|
||||||
|
|
Loading…
Reference in New Issue