[hue] Implementing "[discovery.upnp] Devices may apply a grace period" (#9985)

* [hue] implement PR #2144 in openhab.core
* [hue] add binding configuration parameter; return long

Signed-off-by: Andrew Fiddian-Green <software@whitebear.ch>
pull/10120/head
Andrew Fiddian-Green 2021-02-09 20:52:11 +00:00 committed by GitHub
parent f8d5ae081b
commit 18e028a632
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
4 changed files with 59 additions and 3 deletions

View File

@ -367,3 +367,11 @@ if (receivedEvent == "1000.0")) {
//do stuff
}
```
### UPnP Discovery: Inbox 'Grace Period'
The Hue Bridge can sometimes be late in sending its UPnP 'ssdp:alive' notifications even though it has not really gone offline.
This means that the Hue Bridge could be repeatedly removed from, and (re)added to, the InBox.
Which would lead to confusion in the UI, and repeated logger messages.
To prevent this, the binding tells the OpenHAB core to wait for a further period of time ('grace period') before actually removing the Bridge from the Inbox.
The 'grace period' has a default value of 50 seconds, but it can be fine tuned in the main UI via Settings | Bindings | Hue | Configure.

View File

@ -84,6 +84,9 @@ public class HueBindingConstants {
public static final String EVENT_DIMMER_SWITCH = "dimmer_switch_event";
public static final String EVENT_TAP_SWITCH = "tap_switch_event";
// Binding configuration properties
public static final String REMOVAL_GRACE_PERIOD = "removalGracePeriod";
// Bridge config properties
public static final String HOST = "ipAddress";
public static final String PORT = "port";

View File

@ -15,7 +15,9 @@ package org.openhab.binding.hue.internal.discovery;
import static org.openhab.binding.hue.internal.HueBindingConstants.*;
import static org.openhab.core.thing.Thing.PROPERTY_SERIAL_NUMBER;
import java.io.IOException;
import java.util.Collections;
import java.util.Dictionary;
import java.util.HashMap;
import java.util.Map;
import java.util.Set;
@ -25,13 +27,20 @@ import org.eclipse.jdt.annotation.Nullable;
import org.jupnp.model.meta.DeviceDetails;
import org.jupnp.model.meta.ModelDetails;
import org.jupnp.model.meta.RemoteDevice;
import org.openhab.binding.hue.internal.HueBindingConstants;
import org.openhab.core.config.discovery.DiscoveryResult;
import org.openhab.core.config.discovery.DiscoveryResultBuilder;
import org.openhab.core.config.discovery.upnp.UpnpDiscoveryParticipant;
import org.openhab.core.config.discovery.upnp.internal.UpnpDiscoveryService;
import org.openhab.core.thing.ThingTypeUID;
import org.openhab.core.thing.ThingUID;
import org.osgi.service.cm.Configuration;
import org.osgi.service.cm.ConfigurationAdmin;
import org.osgi.service.component.annotations.Activate;
import org.osgi.service.component.annotations.Component;
import org.osgi.service.component.annotations.Reference;
import org.slf4j.Logger;
import org.slf4j.LoggerFactory;
/**
* The {@link HueBridgeDiscoveryParticipant} is responsible for discovering new and
@ -44,6 +53,18 @@ import org.osgi.service.component.annotations.Component;
@Component(service = UpnpDiscoveryParticipant.class)
public class HueBridgeDiscoveryParticipant implements UpnpDiscoveryParticipant {
private final Logger logger = LoggerFactory.getLogger(HueBridgeDiscoveryParticipant.class);
// Hue bridges have maxAge 100 seconds, so set the default grace period to half of that
private long removalGracePeriodSeconds = 50;
private final ConfigurationAdmin configAdmin;
@Activate
public HueBridgeDiscoveryParticipant(final @Reference ConfigurationAdmin configAdmin) {
this.configAdmin = configAdmin;
}
@Override
public Set<ThingTypeUID> getSupportedThingTypeUIDs() {
return Collections.singleton(THING_TYPE_BRIDGE);
@ -92,4 +113,20 @@ public class HueBridgeDiscoveryParticipant implements UpnpDiscoveryParticipant {
}
return null;
}
@Override
public long getRemovalGracePeriodSeconds(RemoteDevice device) {
try {
Configuration conf = configAdmin.getConfiguration("binding.hue");
Dictionary<String, @Nullable Object> properties = conf.getProperties();
Object property = properties.get(HueBindingConstants.REMOVAL_GRACE_PERIOD);
if (property != null) {
removalGracePeriodSeconds = Long.parseLong(property.toString());
}
} catch (IOException | IllegalStateException | NumberFormatException e) {
// fall through to pre-initialised (default) value
}
logger.trace("getRemovalGracePeriodSeconds={}", removalGracePeriodSeconds);
return removalGracePeriodSeconds;
}
}

View File

@ -3,8 +3,16 @@
xmlns:binding="https://openhab.org/schemas/binding/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/binding/v1.0.0 https://openhab.org/schemas/binding-1.0.0.xsd">
<name>hue Binding</name>
<description>The hue Binding integrates the Philips hue system. It
allows to control hue bulbs.</description>
<name>Hue Binding</name>
<description>The Hue Binding integrates the Philips Hue system. It allows to control Hue bulbs.</description>
<config-description>
<parameter name="removalGracePeriod" type="integer" min="0" step="1" unit="s">
<label>Removal Grace Period</label>
<description>Extra grace period (seconds) that UPnP discovery shall wait before removing a lost Bridge from the
Inbox. Default is 50 seconds.</description>
<default>50</default>
</parameter>
</config-description>
</binding:binding>