"""Support for APCUPSd sensors."""
|
|
import logging
|
|
|
|
from apcaccess.status import ALL_UNITS
|
|
import voluptuous as vol
|
|
|
|
from homeassistant.components.sensor import PLATFORM_SCHEMA, SensorEntity
|
|
from homeassistant.const import (
|
|
CONF_RESOURCES,
|
|
ELECTRICAL_CURRENT_AMPERE,
|
|
ELECTRICAL_VOLT_AMPERE,
|
|
FREQUENCY_HERTZ,
|
|
PERCENTAGE,
|
|
POWER_WATT,
|
|
TEMP_CELSIUS,
|
|
TIME_MINUTES,
|
|
TIME_SECONDS,
|
|
VOLT,
|
|
)
|
|
import homeassistant.helpers.config_validation as cv
|
|
|
|
from . import DOMAIN
|
|
|
|
_LOGGER = logging.getLogger(__name__)
|
|
|
|
SENSOR_PREFIX = "UPS "
|
|
SENSOR_TYPES = {
|
|
"alarmdel": ["Alarm Delay", "", "mdi:alarm"],
|
|
"ambtemp": ["Ambient Temperature", "", "mdi:thermometer"],
|
|
"apc": ["Status Data", "", "mdi:information-outline"],
|
|
"apcmodel": ["Model", "", "mdi:information-outline"],
|
|
"badbatts": ["Bad Batteries", "", "mdi:information-outline"],
|
|
"battdate": ["Battery Replaced", "", "mdi:calendar-clock"],
|
|
"battstat": ["Battery Status", "", "mdi:information-outline"],
|
|
"battv": ["Battery Voltage", VOLT, "mdi:flash"],
|
|
"bcharge": ["Battery", PERCENTAGE, "mdi:battery"],
|
|
"cable": ["Cable Type", "", "mdi:ethernet-cable"],
|
|
"cumonbatt": ["Total Time on Battery", "", "mdi:timer-outline"],
|
|
"date": ["Status Date", "", "mdi:calendar-clock"],
|
|
"dipsw": ["Dip Switch Settings", "", "mdi:information-outline"],
|
|
"dlowbatt": ["Low Battery Signal", "", "mdi:clock-alert"],
|
|
"driver": ["Driver", "", "mdi:information-outline"],
|
|
"dshutd": ["Shutdown Delay", "", "mdi:timer-outline"],
|
|
"dwake": ["Wake Delay", "", "mdi:timer-outline"],
|
|
"endapc": ["Date and Time", "", "mdi:calendar-clock"],
|
|
"extbatts": ["External Batteries", "", "mdi:information-outline"],
|
|
"firmware": ["Firmware Version", "", "mdi:information-outline"],
|
|
"hitrans": ["Transfer High", VOLT, "mdi:flash"],
|
|
"hostname": ["Hostname", "", "mdi:information-outline"],
|
|
"humidity": ["Ambient Humidity", PERCENTAGE, "mdi:water-percent"],
|
|
"itemp": ["Internal Temperature", TEMP_CELSIUS, "mdi:thermometer"],
|
|
"lastxfer": ["Last Transfer", "", "mdi:transfer"],
|
|
"linefail": ["Input Voltage Status", "", "mdi:information-outline"],
|
|
"linefreq": ["Line Frequency", FREQUENCY_HERTZ, "mdi:information-outline"],
|
|
"linev": ["Input Voltage", VOLT, "mdi:flash"],
|
|
"loadpct": ["Load", PERCENTAGE, "mdi:gauge"],
|
|
"loadapnt": ["Load Apparent Power", PERCENTAGE, "mdi:gauge"],
|
|
"lotrans": ["Transfer Low", VOLT, "mdi:flash"],
|
|
"mandate": ["Manufacture Date", "", "mdi:calendar"],
|
|
"masterupd": ["Master Update", "", "mdi:information-outline"],
|
|
"maxlinev": ["Input Voltage High", VOLT, "mdi:flash"],
|
|
"maxtime": ["Battery Timeout", "", "mdi:timer-off-outline"],
|
|
"mbattchg": ["Battery Shutdown", PERCENTAGE, "mdi:battery-alert"],
|
|
"minlinev": ["Input Voltage Low", VOLT, "mdi:flash"],
|
|
"mintimel": ["Shutdown Time", "", "mdi:timer-outline"],
|
|
"model": ["Model", "", "mdi:information-outline"],
|
|
"nombattv": ["Battery Nominal Voltage", VOLT, "mdi:flash"],
|
|
"nominv": ["Nominal Input Voltage", VOLT, "mdi:flash"],
|
|
"nomoutv": ["Nominal Output Voltage", VOLT, "mdi:flash"],
|
|
"nompower": ["Nominal Output Power", POWER_WATT, "mdi:flash"],
|
|
"nomapnt": ["Nominal Apparent Power", ELECTRICAL_VOLT_AMPERE, "mdi:flash"],
|
|
"numxfers": ["Transfer Count", "", "mdi:counter"],
|
|
"outcurnt": ["Output Current", ELECTRICAL_CURRENT_AMPERE, "mdi:flash"],
|
|
"outputv": ["Output Voltage", VOLT, "mdi:flash"],
|
|
"reg1": ["Register 1 Fault", "", "mdi:information-outline"],
|
|
"reg2": ["Register 2 Fault", "", "mdi:information-outline"],
|
|
"reg3": ["Register 3 Fault", "", "mdi:information-outline"],
|
|
"retpct": ["Restore Requirement", PERCENTAGE, "mdi:battery-alert"],
|
|
"selftest": ["Last Self Test", "", "mdi:calendar-clock"],
|
|
"sense": ["Sensitivity", "", "mdi:information-outline"],
|
|
"serialno": ["Serial Number", "", "mdi:information-outline"],
|
|
"starttime": ["Startup Time", "", "mdi:calendar-clock"],
|
|
"statflag": ["Status Flag", "", "mdi:information-outline"],
|
|
"status": ["Status", "", "mdi:information-outline"],
|
|
"stesti": ["Self Test Interval", "", "mdi:information-outline"],
|
|
"timeleft": ["Time Left", "", "mdi:clock-alert"],
|
|
"tonbatt": ["Time on Battery", "", "mdi:timer-outline"],
|
|
"upsmode": ["Mode", "", "mdi:information-outline"],
|
|
"upsname": ["Name", "", "mdi:information-outline"],
|
|
"version": ["Daemon Info", "", "mdi:information-outline"],
|
|
"xoffbat": ["Transfer from Battery", "", "mdi:transfer"],
|
|
"xoffbatt": ["Transfer from Battery", "", "mdi:transfer"],
|
|
"xonbatt": ["Transfer to Battery", "", "mdi:transfer"],
|
|
}
|
|
|
|
SPECIFIC_UNITS = {"ITEMP": TEMP_CELSIUS}
|
|
INFERRED_UNITS = {
|
|
" Minutes": TIME_MINUTES,
|
|
" Seconds": TIME_SECONDS,
|
|
" Percent": PERCENTAGE,
|
|
" Volts": VOLT,
|
|
" Ampere": ELECTRICAL_CURRENT_AMPERE,
|
|
" Volt-Ampere": ELECTRICAL_VOLT_AMPERE,
|
|
" Watts": POWER_WATT,
|
|
" Hz": FREQUENCY_HERTZ,
|
|
" C": TEMP_CELSIUS,
|
|
" Percent Load Capacity": PERCENTAGE,
|
|
}
|
|
|
|
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
|
|
{
|
|
vol.Required(CONF_RESOURCES, default=[]): vol.All(
|
|
cv.ensure_list, [vol.In(SENSOR_TYPES)]
|
|
)
|
|
}
|
|
)
|
|
|
|
|
|
def setup_platform(hass, config, add_entities, discovery_info=None):
|
|
"""Set up the APCUPSd sensors."""
|
|
apcups_data = hass.data[DOMAIN]
|
|
entities = []
|
|
|
|
for resource in config[CONF_RESOURCES]:
|
|
sensor_type = resource.lower()
|
|
|
|
if sensor_type not in SENSOR_TYPES:
|
|
SENSOR_TYPES[sensor_type] = [
|
|
sensor_type.title(),
|
|
"",
|
|
"mdi:information-outline",
|
|
]
|
|
|
|
if sensor_type.upper() not in apcups_data.status:
|
|
_LOGGER.warning(
|
|
"Sensor type: %s does not appear in the APCUPSd status output",
|
|
sensor_type,
|
|
)
|
|
|
|
entities.append(APCUPSdSensor(apcups_data, sensor_type))
|
|
|
|
add_entities(entities, True)
|
|
|
|
|
|
def infer_unit(value):
|
|
"""If the value ends with any of the units from ALL_UNITS.
|
|
|
|
Split the unit off the end of the value and return the value, unit tuple
|
|
pair. Else return the original value and None as the unit.
|
|
"""
|
|
|
|
for unit in ALL_UNITS:
|
|
if value.endswith(unit):
|
|
return value[: -len(unit)], INFERRED_UNITS.get(unit, unit.strip())
|
|
return value, None
|
|
|
|
|
|
class APCUPSdSensor(SensorEntity):
|
|
"""Representation of a sensor entity for APCUPSd status values."""
|
|
|
|
def __init__(self, data, sensor_type):
|
|
"""Initialize the sensor."""
|
|
self._data = data
|
|
self.type = sensor_type
|
|
self._name = SENSOR_PREFIX + SENSOR_TYPES[sensor_type][0]
|
|
self._unit = SENSOR_TYPES[sensor_type][1]
|
|
self._inferred_unit = None
|
|
self._state = None
|
|
|
|
@property
|
|
def name(self):
|
|
"""Return the name of the UPS sensor."""
|
|
return self._name
|
|
|
|
@property
|
|
def icon(self):
|
|
"""Icon to use in the frontend, if any."""
|
|
return SENSOR_TYPES[self.type][2]
|
|
|
|
@property
|
|
def state(self):
|
|
"""Return true if the UPS is online, else False."""
|
|
return self._state
|
|
|
|
@property
|
|
def unit_of_measurement(self):
|
|
"""Return the unit of measurement of this entity, if any."""
|
|
if not self._unit:
|
|
return self._inferred_unit
|
|
return self._unit
|
|
|
|
def update(self):
|
|
"""Get the latest status and use it to update our sensor state."""
|
|
if self.type.upper() not in self._data.status:
|
|
self._state = None
|
|
self._inferred_unit = None
|
|
else:
|
|
self._state, self._inferred_unit = infer_unit(
|
|
self._data.status[self.type.upper()]
|
|
)
|