"""Voluptuous schemas for the KNX integration."""
from __future__ import annotations
from abc import ABC
from typing import Any, ClassVar
import voluptuous as vol
from xknx import XKNX
from xknx.devices.climate import SetpointShiftMode
from xknx.dpt import DPTBase
from xknx.exceptions import CouldNotParseAddress
from xknx.io import DEFAULT_MCAST_GRP, DEFAULT_MCAST_PORT
from xknx.telegram.address import IndividualAddress, parse_device_group_address
from homeassistant.components.binary_sensor import (
DEVICE_CLASSES as BINARY_SENSOR_DEVICE_CLASSES,
)
from homeassistant.components.cover import DEVICE_CLASSES as COVER_DEVICE_CLASSES
from homeassistant.const import (
CONF_DEVICE_CLASS,
CONF_ENTITY_ID,
CONF_HOST,
CONF_NAME,
CONF_PORT,
CONF_TYPE,
)
import homeassistant.helpers.config_validation as cv
from .const import (
CONF_INVERT,
CONF_KNX_EXPOSE,
CONF_KNX_INDIVIDUAL_ADDRESS,
CONF_KNX_ROUTING,
CONF_KNX_TUNNELING,
CONF_RESET_AFTER,
CONF_STATE_ADDRESS,
CONF_SYNC_STATE,
CONTROLLER_MODES,
KNX_ADDRESS,
PRESET_MODES,
ColorTempModes,
SupportedPlatforms,
)
##################
# KNX VALIDATORS
##################
def ga_validator(value: Any) -> str | int:
"""Validate that value is parsable as GroupAddress or InternalGroupAddress."""
if isinstance(value, (str, int)):
try:
parse_device_group_address(value)
return value
except CouldNotParseAddress:
pass
raise vol.Invalid(
f"value '{value}' is not a valid KNX group address '<main>/<middle>/<sub>', '<main>/<sub>' "
"or '<free>' (eg.'1/2/3', '9/234', '123'), nor xknx internal address 'i-<string>'."
)
ga_list_validator = vol.All(cv.ensure_list, [ga_validator])
ia_validator = vol.Any(
cv.matches_regex(IndividualAddress.ADDRESS_RE.pattern),
vol.All(vol.Coerce(int), vol.Range(min=1, max=65535)),
msg="value does not match pattern for KNX individual address '<area>.<line>.<device>' (eg.'1.1.100')",
)
def sensor_type_validator(value: Any) -> str | int:
"""Validate that value is parsable as sensor type."""
if isinstance(value, (str, int)) and DPTBase.parse_transcoder(value) is not None:
return value
raise vol.Invalid(f"value '{value}' is not a valid sensor type.")
sync_state_validator = vol.Any(
vol.All(vol.Coerce(int), vol.Range(min=2, max=1440)),
cv.boolean,
cv.matches_regex(r"^(init|expire|every)( \d*)?$"),
)
##############
# CONNECTION
##############
class ConnectionSchema:
"""Voluptuous schema for KNX connection."""
CONF_KNX_LOCAL_IP = "local_ip"
CONF_KNX_MCAST_GRP = "multicast_group"
CONF_KNX_MCAST_PORT = "multicast_port"
CONF_KNX_RATE_LIMIT = "rate_limit"
CONF_KNX_ROUTE_BACK = "route_back"
CONF_KNX_STATE_UPDATER = "state_updater"
TUNNELING_SCHEMA = vol.Schema(
{
vol.Optional(CONF_PORT, default=DEFAULT_MCAST_PORT): cv.port,
vol.Required(CONF_HOST): cv.string,
vol.Optional(CONF_KNX_LOCAL_IP): cv.string,
vol.Optional(CONF_KNX_ROUTE_BACK, default=False): cv.boolean,
}
)
ROUTING_SCHEMA = vol.Maybe(vol.Schema({vol.Optional(CONF_KNX_LOCAL_IP): cv.string}))
SCHEMA = {
vol.Exclusive(CONF_KNX_ROUTING, "connection_type"): ROUTING_SCHEMA,
vol.Exclusive(CONF_KNX_TUNNELING, "connection_type"): TUNNELING_SCHEMA,
vol.Optional(
CONF_KNX_INDIVIDUAL_ADDRESS, default=XKNX.DEFAULT_ADDRESS
): ia_validator,
vol.Optional(CONF_KNX_MCAST_GRP, default=DEFAULT_MCAST_GRP): cv.string,
vol.Optional(CONF_KNX_MCAST_PORT, default=DEFAULT_MCAST_PORT): cv.port,
vol.Optional(CONF_KNX_STATE_UPDATER, default=True): cv.boolean,
vol.Optional(CONF_KNX_RATE_LIMIT, default=20): vol.All(
vol.Coerce(int), vol.Range(min=1, max=100)
),
}
#############
# PLATFORMS
#############
class KNXPlatformSchema(ABC):
"""Voluptuous schema for KNX platform entity configuration."""
PLATFORM_NAME: ClassVar[str]
ENTITY_SCHEMA: ClassVar[vol.Schema]
@classmethod
def platform_node(cls) -> dict[vol.Optional, vol.All]:
"""Return a schema node for the platform."""
return {
vol.Optional(cls.PLATFORM_NAME): vol.All(
cv.ensure_list, [cls.ENTITY_SCHEMA]
)
}
class BinarySensorSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX binary sensors."""
PLATFORM_NAME = SupportedPlatforms.BINARY_SENSOR.value
CONF_STATE_ADDRESS = CONF_STATE_ADDRESS
CONF_SYNC_STATE = CONF_SYNC_STATE
CONF_INVERT = CONF_INVERT
CONF_IGNORE_INTERNAL_STATE = "ignore_internal_state"
CONF_CONTEXT_TIMEOUT = "context_timeout"
CONF_RESET_AFTER = CONF_RESET_AFTER
DEFAULT_NAME = "KNX Binary Sensor"
ENTITY_SCHEMA = vol.All(
# deprecated since September 2020
cv.deprecated("significant_bit"),
cv.deprecated("automation"),
vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator,
vol.Optional(CONF_IGNORE_INTERNAL_STATE, default=False): cv.boolean,
vol.Optional(CONF_INVERT, default=False): cv.boolean,
vol.Required(CONF_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_CONTEXT_TIMEOUT): vol.All(
vol.Coerce(float), vol.Range(min=0, max=10)
),
vol.Optional(CONF_DEVICE_CLASS): vol.In(BINARY_SENSOR_DEVICE_CLASSES),
vol.Optional(CONF_RESET_AFTER): cv.positive_float,
}
),
)
class ClimateSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX climate devices."""
PLATFORM_NAME = SupportedPlatforms.CLIMATE.value
CONF_SETPOINT_SHIFT_ADDRESS = "setpoint_shift_address"
CONF_SETPOINT_SHIFT_STATE_ADDRESS = "setpoint_shift_state_address"
CONF_SETPOINT_SHIFT_MODE = "setpoint_shift_mode"
CONF_SETPOINT_SHIFT_MAX = "setpoint_shift_max"
CONF_SETPOINT_SHIFT_MIN = "setpoint_shift_min"
CONF_TEMPERATURE_ADDRESS = "temperature_address"
CONF_TEMPERATURE_STEP = "temperature_step"
CONF_TARGET_TEMPERATURE_ADDRESS = "target_temperature_address"
CONF_TARGET_TEMPERATURE_STATE_ADDRESS = "target_temperature_state_address"
CONF_OPERATION_MODE_ADDRESS = "operation_mode_address"
CONF_OPERATION_MODE_STATE_ADDRESS = "operation_mode_state_address"
CONF_CONTROLLER_STATUS_ADDRESS = "controller_status_address"
CONF_CONTROLLER_STATUS_STATE_ADDRESS = "controller_status_state_address"
CONF_CONTROLLER_MODE_ADDRESS = "controller_mode_address"
CONF_CONTROLLER_MODE_STATE_ADDRESS = "controller_mode_state_address"
CONF_HEAT_COOL_ADDRESS = "heat_cool_address"
CONF_HEAT_COOL_STATE_ADDRESS = "heat_cool_state_address"
CONF_OPERATION_MODE_FROST_PROTECTION_ADDRESS = (
"operation_mode_frost_protection_address"
)
CONF_OPERATION_MODE_NIGHT_ADDRESS = "operation_mode_night_address"
CONF_OPERATION_MODE_COMFORT_ADDRESS = "operation_mode_comfort_address"
CONF_OPERATION_MODE_STANDBY_ADDRESS = "operation_mode_standby_address"
CONF_OPERATION_MODES = "operation_modes"
CONF_CONTROLLER_MODES = "controller_modes"
CONF_ON_OFF_ADDRESS = "on_off_address"
CONF_ON_OFF_STATE_ADDRESS = "on_off_state_address"
CONF_ON_OFF_INVERT = "on_off_invert"
CONF_MIN_TEMP = "min_temp"
CONF_MAX_TEMP = "max_temp"
DEFAULT_NAME = "KNX Climate"
DEFAULT_SETPOINT_SHIFT_MODE = "DPT6010"
DEFAULT_SETPOINT_SHIFT_MAX = 6
DEFAULT_SETPOINT_SHIFT_MIN = -6
DEFAULT_TEMPERATURE_STEP = 0.1
DEFAULT_ON_OFF_INVERT = False
ENTITY_SCHEMA = vol.All(
# deprecated since September 2020
cv.deprecated("setpoint_shift_step", replacement_key=CONF_TEMPERATURE_STEP),
# deprecated since 2021.6
cv.deprecated("create_temperature_sensors"),
vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(
CONF_SETPOINT_SHIFT_MAX, default=DEFAULT_SETPOINT_SHIFT_MAX
): vol.All(int, vol.Range(min=0, max=32)),
vol.Optional(
CONF_SETPOINT_SHIFT_MIN, default=DEFAULT_SETPOINT_SHIFT_MIN
): vol.All(int, vol.Range(min=-32, max=0)),
vol.Optional(
CONF_TEMPERATURE_STEP, default=DEFAULT_TEMPERATURE_STEP
): vol.All(float, vol.Range(min=0, max=2)),
vol.Required(CONF_TEMPERATURE_ADDRESS): ga_list_validator,
vol.Required(CONF_TARGET_TEMPERATURE_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_TARGET_TEMPERATURE_ADDRESS): ga_list_validator,
vol.Inclusive(
CONF_SETPOINT_SHIFT_ADDRESS,
"setpoint_shift",
msg="'setpoint_shift_address' and 'setpoint_shift_state_address' "
"are required for setpoint_shift configuration",
): ga_list_validator,
vol.Inclusive(
CONF_SETPOINT_SHIFT_STATE_ADDRESS,
"setpoint_shift",
msg="'setpoint_shift_address' and 'setpoint_shift_state_address' "
"are required for setpoint_shift configuration",
): ga_list_validator,
vol.Optional(CONF_SETPOINT_SHIFT_MODE): vol.Maybe(
vol.All(vol.Upper, cv.enum(SetpointShiftMode))
),
vol.Optional(CONF_OPERATION_MODE_ADDRESS): ga_list_validator,
vol.Optional(CONF_OPERATION_MODE_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_CONTROLLER_STATUS_ADDRESS): ga_list_validator,
vol.Optional(CONF_CONTROLLER_STATUS_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_CONTROLLER_MODE_ADDRESS): ga_list_validator,
vol.Optional(CONF_CONTROLLER_MODE_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_HEAT_COOL_ADDRESS): ga_list_validator,
vol.Optional(CONF_HEAT_COOL_STATE_ADDRESS): ga_list_validator,
vol.Optional(
CONF_OPERATION_MODE_FROST_PROTECTION_ADDRESS
): ga_list_validator,
vol.Optional(CONF_OPERATION_MODE_NIGHT_ADDRESS): ga_list_validator,
vol.Optional(CONF_OPERATION_MODE_COMFORT_ADDRESS): ga_list_validator,
vol.Optional(CONF_OPERATION_MODE_STANDBY_ADDRESS): ga_list_validator,
vol.Optional(CONF_ON_OFF_ADDRESS): ga_list_validator,
vol.Optional(CONF_ON_OFF_STATE_ADDRESS): ga_list_validator,
vol.Optional(
CONF_ON_OFF_INVERT, default=DEFAULT_ON_OFF_INVERT
): cv.boolean,
vol.Optional(CONF_OPERATION_MODES): vol.All(
cv.ensure_list, [vol.In(PRESET_MODES)]
),
vol.Optional(CONF_CONTROLLER_MODES): vol.All(
cv.ensure_list, [vol.In(CONTROLLER_MODES)]
),
vol.Optional(CONF_MIN_TEMP): vol.Coerce(float),
vol.Optional(CONF_MAX_TEMP): vol.Coerce(float),
}
),
)
class CoverSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX covers."""
PLATFORM_NAME = SupportedPlatforms.COVER.value
CONF_MOVE_LONG_ADDRESS = "move_long_address"
CONF_MOVE_SHORT_ADDRESS = "move_short_address"
CONF_STOP_ADDRESS = "stop_address"
CONF_POSITION_ADDRESS = "position_address"
CONF_POSITION_STATE_ADDRESS = "position_state_address"
CONF_ANGLE_ADDRESS = "angle_address"
CONF_ANGLE_STATE_ADDRESS = "angle_state_address"
CONF_TRAVELLING_TIME_DOWN = "travelling_time_down"
CONF_TRAVELLING_TIME_UP = "travelling_time_up"
CONF_INVERT_POSITION = "invert_position"
CONF_INVERT_ANGLE = "invert_angle"
DEFAULT_TRAVEL_TIME = 25
DEFAULT_NAME = "KNX Cover"
ENTITY_SCHEMA = vol.All(
vol.Schema(
{
vol.Required(
vol.Any(CONF_MOVE_LONG_ADDRESS, CONF_POSITION_ADDRESS),
msg=f"At least one of '{CONF_MOVE_LONG_ADDRESS}' or '{CONF_POSITION_ADDRESS}' is required.",
): object,
},
extra=vol.ALLOW_EXTRA,
),
vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_MOVE_LONG_ADDRESS): ga_list_validator,
vol.Optional(CONF_MOVE_SHORT_ADDRESS): ga_list_validator,
vol.Optional(CONF_STOP_ADDRESS): ga_list_validator,
vol.Optional(CONF_POSITION_ADDRESS): ga_list_validator,
vol.Optional(CONF_POSITION_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_ANGLE_ADDRESS): ga_list_validator,
vol.Optional(CONF_ANGLE_STATE_ADDRESS): ga_list_validator,
vol.Optional(
CONF_TRAVELLING_TIME_DOWN, default=DEFAULT_TRAVEL_TIME
): cv.positive_float,
vol.Optional(
CONF_TRAVELLING_TIME_UP, default=DEFAULT_TRAVEL_TIME
): cv.positive_float,
vol.Optional(CONF_INVERT_POSITION, default=False): cv.boolean,
vol.Optional(CONF_INVERT_ANGLE, default=False): cv.boolean,
vol.Optional(CONF_DEVICE_CLASS): vol.In(COVER_DEVICE_CLASSES),
}
),
)
class ExposeSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX exposures."""
PLATFORM_NAME = CONF_KNX_EXPOSE
CONF_KNX_EXPOSE_TYPE = CONF_TYPE
CONF_KNX_EXPOSE_ATTRIBUTE = "attribute"
CONF_KNX_EXPOSE_BINARY = "binary"
CONF_KNX_EXPOSE_DEFAULT = "default"
EXPOSE_TIME_TYPES = [
"time",
"date",
"datetime",
]
EXPOSE_TIME_SCHEMA = vol.Schema(
{
vol.Required(CONF_KNX_EXPOSE_TYPE): vol.All(
cv.string, str.lower, vol.In(EXPOSE_TIME_TYPES)
),
vol.Required(KNX_ADDRESS): ga_validator,
}
)
EXPOSE_SENSOR_SCHEMA = vol.Schema(
{
vol.Required(CONF_KNX_EXPOSE_TYPE): vol.Any(
CONF_KNX_EXPOSE_BINARY, sensor_type_validator
),
vol.Required(KNX_ADDRESS): ga_validator,
vol.Required(CONF_ENTITY_ID): cv.entity_id,
vol.Optional(CONF_KNX_EXPOSE_ATTRIBUTE): cv.string,
vol.Optional(CONF_KNX_EXPOSE_DEFAULT): cv.match_all,
}
)
ENTITY_SCHEMA = vol.Any(EXPOSE_SENSOR_SCHEMA, EXPOSE_TIME_SCHEMA)
class FanSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX fans."""
PLATFORM_NAME = SupportedPlatforms.FAN.value
CONF_STATE_ADDRESS = CONF_STATE_ADDRESS
CONF_OSCILLATION_ADDRESS = "oscillation_address"
CONF_OSCILLATION_STATE_ADDRESS = "oscillation_state_address"
CONF_MAX_STEP = "max_step"
DEFAULT_NAME = "KNX Fan"
ENTITY_SCHEMA = vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Required(KNX_ADDRESS): ga_list_validator,
vol.Optional(CONF_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_OSCILLATION_ADDRESS): ga_list_validator,
vol.Optional(CONF_OSCILLATION_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_MAX_STEP): cv.byte,
}
)
class LightSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX lights."""
PLATFORM_NAME = SupportedPlatforms.LIGHT.value
CONF_STATE_ADDRESS = CONF_STATE_ADDRESS
CONF_BRIGHTNESS_ADDRESS = "brightness_address"
CONF_BRIGHTNESS_STATE_ADDRESS = "brightness_state_address"
CONF_COLOR_ADDRESS = "color_address"
CONF_COLOR_STATE_ADDRESS = "color_state_address"
CONF_COLOR_TEMP_ADDRESS = "color_temperature_address"
CONF_COLOR_TEMP_STATE_ADDRESS = "color_temperature_state_address"
CONF_COLOR_TEMP_MODE = "color_temperature_mode"
CONF_RGBW_ADDRESS = "rgbw_address"
CONF_RGBW_STATE_ADDRESS = "rgbw_state_address"
CONF_XYY_ADDRESS = "xyy_address"
CONF_XYY_STATE_ADDRESS = "xyy_state_address"
CONF_MIN_KELVIN = "min_kelvin"
CONF_MAX_KELVIN = "max_kelvin"
DEFAULT_NAME = "KNX Light"
DEFAULT_COLOR_TEMP_MODE = "absolute"
DEFAULT_MIN_KELVIN = 2700 # 370 mireds
DEFAULT_MAX_KELVIN = 6000 # 166 mireds
CONF_INDIVIDUAL_COLORS = "individual_colors"
CONF_RED = "red"
CONF_GREEN = "green"
CONF_BLUE = "blue"
CONF_WHITE = "white"
COLOR_SCHEMA = vol.Schema(
{
vol.Optional(KNX_ADDRESS): ga_list_validator,
vol.Optional(CONF_STATE_ADDRESS): ga_list_validator,
vol.Required(CONF_BRIGHTNESS_ADDRESS): ga_list_validator,
vol.Optional(CONF_BRIGHTNESS_STATE_ADDRESS): ga_list_validator,
}
)
ENTITY_SCHEMA = vol.All(
vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(KNX_ADDRESS): ga_list_validator,
vol.Optional(CONF_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_BRIGHTNESS_ADDRESS): ga_list_validator,
vol.Optional(CONF_BRIGHTNESS_STATE_ADDRESS): ga_list_validator,
vol.Exclusive(CONF_INDIVIDUAL_COLORS, "color"): {
vol.Inclusive(
CONF_RED,
"individual_colors",
msg="'red', 'green' and 'blue' are required for individual colors configuration",
): COLOR_SCHEMA,
vol.Inclusive(
CONF_GREEN,
"individual_colors",
msg="'red', 'green' and 'blue' are required for individual colors configuration",
): COLOR_SCHEMA,
vol.Inclusive(
CONF_BLUE,
"individual_colors",
msg="'red', 'green' and 'blue' are required for individual colors configuration",
): COLOR_SCHEMA,
vol.Optional(CONF_WHITE): COLOR_SCHEMA,
},
vol.Exclusive(CONF_COLOR_ADDRESS, "color"): ga_list_validator,
vol.Optional(CONF_COLOR_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_COLOR_TEMP_ADDRESS): ga_list_validator,
vol.Optional(CONF_COLOR_TEMP_STATE_ADDRESS): ga_list_validator,
vol.Optional(
CONF_COLOR_TEMP_MODE, default=DEFAULT_COLOR_TEMP_MODE
): vol.All(vol.Upper, cv.enum(ColorTempModes)),
vol.Exclusive(CONF_RGBW_ADDRESS, "color"): ga_list_validator,
vol.Optional(CONF_RGBW_STATE_ADDRESS): ga_list_validator,
vol.Exclusive(CONF_XYY_ADDRESS, "color"): ga_list_validator,
vol.Optional(CONF_XYY_STATE_ADDRESS): ga_list_validator,
vol.Optional(CONF_MIN_KELVIN, default=DEFAULT_MIN_KELVIN): vol.All(
vol.Coerce(int), vol.Range(min=1)
),
vol.Optional(CONF_MAX_KELVIN, default=DEFAULT_MAX_KELVIN): vol.All(
vol.Coerce(int), vol.Range(min=1)
),
}
),
vol.Any(
# either global "address" or "individual_colors" is required
vol.Schema(
{
# brightness addresses are required in COLOR_SCHEMA
vol.Required(CONF_INDIVIDUAL_COLORS): object,
},
extra=vol.ALLOW_EXTRA,
),
vol.Schema(
{
vol.Required(KNX_ADDRESS): object,
},
extra=vol.ALLOW_EXTRA,
),
),
)
class NotifySchema(KNXPlatformSchema):
"""Voluptuous schema for KNX notifications."""
PLATFORM_NAME = SupportedPlatforms.NOTIFY.value
DEFAULT_NAME = "KNX Notify"
ENTITY_SCHEMA = vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Required(KNX_ADDRESS): ga_validator,
}
)
class SceneSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX scenes."""
PLATFORM_NAME = SupportedPlatforms.SCENE.value
CONF_SCENE_NUMBER = "scene_number"
DEFAULT_NAME = "KNX SCENE"
ENTITY_SCHEMA = vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Required(KNX_ADDRESS): ga_list_validator,
vol.Required(CONF_SCENE_NUMBER): vol.All(
vol.Coerce(int), vol.Range(min=1, max=64)
),
}
)
class SensorSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX sensors."""
PLATFORM_NAME = SupportedPlatforms.SENSOR.value
CONF_ALWAYS_CALLBACK = "always_callback"
CONF_STATE_ADDRESS = CONF_STATE_ADDRESS
CONF_SYNC_STATE = CONF_SYNC_STATE
DEFAULT_NAME = "KNX Sensor"
ENTITY_SCHEMA = vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator,
vol.Optional(CONF_ALWAYS_CALLBACK, default=False): cv.boolean,
vol.Required(CONF_TYPE): sensor_type_validator,
vol.Required(CONF_STATE_ADDRESS): ga_list_validator,
}
)
class SwitchSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX switches."""
PLATFORM_NAME = SupportedPlatforms.SWITCH.value
CONF_INVERT = CONF_INVERT
CONF_STATE_ADDRESS = CONF_STATE_ADDRESS
DEFAULT_NAME = "KNX Switch"
ENTITY_SCHEMA = vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_INVERT, default=False): cv.boolean,
vol.Required(KNX_ADDRESS): ga_list_validator,
vol.Optional(CONF_STATE_ADDRESS): ga_list_validator,
}
)
class WeatherSchema(KNXPlatformSchema):
"""Voluptuous schema for KNX weather station."""
PLATFORM_NAME = SupportedPlatforms.WEATHER.value
CONF_SYNC_STATE = CONF_SYNC_STATE
CONF_KNX_TEMPERATURE_ADDRESS = "address_temperature"
CONF_KNX_BRIGHTNESS_SOUTH_ADDRESS = "address_brightness_south"
CONF_KNX_BRIGHTNESS_EAST_ADDRESS = "address_brightness_east"
CONF_KNX_BRIGHTNESS_WEST_ADDRESS = "address_brightness_west"
CONF_KNX_BRIGHTNESS_NORTH_ADDRESS = "address_brightness_north"
CONF_KNX_WIND_SPEED_ADDRESS = "address_wind_speed"
CONF_KNX_WIND_BEARING_ADDRESS = "address_wind_bearing"
CONF_KNX_RAIN_ALARM_ADDRESS = "address_rain_alarm"
CONF_KNX_FROST_ALARM_ADDRESS = "address_frost_alarm"
CONF_KNX_WIND_ALARM_ADDRESS = "address_wind_alarm"
CONF_KNX_DAY_NIGHT_ADDRESS = "address_day_night"
CONF_KNX_AIR_PRESSURE_ADDRESS = "address_air_pressure"
CONF_KNX_HUMIDITY_ADDRESS = "address_humidity"
DEFAULT_NAME = "KNX Weather Station"
ENTITY_SCHEMA = vol.All(
# deprecated since 2021.6
cv.deprecated("create_sensors"),
vol.Schema(
{
vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string,
vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator,
vol.Required(CONF_KNX_TEMPERATURE_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_BRIGHTNESS_SOUTH_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_BRIGHTNESS_EAST_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_BRIGHTNESS_WEST_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_BRIGHTNESS_NORTH_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_WIND_SPEED_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_WIND_BEARING_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_RAIN_ALARM_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_FROST_ALARM_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_WIND_ALARM_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_DAY_NIGHT_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_AIR_PRESSURE_ADDRESS): ga_list_validator,
vol.Optional(CONF_KNX_HUMIDITY_ADDRESS): ga_list_validator,
}
),
)