"""Constants for the opentherm_gw integration."""
import pyotgw.vars as gw_vars
from homeassistant.components.binary_sensor import DEVICE_CLASS_PROBLEM
from homeassistant.const import (
DEVICE_CLASS_TEMPERATURE,
PERCENTAGE,
PRESSURE_BAR,
TEMP_CELSIUS,
TIME_HOURS,
TIME_MINUTES,
)
ATTR_GW_ID = "gateway_id"
ATTR_LEVEL = "level"
ATTR_DHW_OVRD = "dhw_override"
ATTR_CH_OVRD = "ch_override"
CONF_CLIMATE = "climate"
CONF_FLOOR_TEMP = "floor_temperature"
CONF_PRECISION = "precision"
CONF_READ_PRECISION = "read_precision"
CONF_SET_PRECISION = "set_precision"
CONF_TEMPORARY_OVRD_MODE = "temporary_override_mode"
DATA_GATEWAYS = "gateways"
DATA_OPENTHERM_GW = "opentherm_gw"
DEVICE_CLASS_COLD = "cold"
DEVICE_CLASS_HEAT = "heat"
DOMAIN = "opentherm_gw"
SERVICE_RESET_GATEWAY = "reset_gateway"
SERVICE_SET_CH_OVRD = "set_central_heating_ovrd"
SERVICE_SET_CLOCK = "set_clock"
SERVICE_SET_CONTROL_SETPOINT = "set_control_setpoint"
SERVICE_SET_HOT_WATER_SETPOINT = "set_hot_water_setpoint"
SERVICE_SET_HOT_WATER_OVRD = "set_hot_water_ovrd"
SERVICE_SET_GPIO_MODE = "set_gpio_mode"
SERVICE_SET_LED_MODE = "set_led_mode"
SERVICE_SET_MAX_MOD = "set_max_modulation"
SERVICE_SET_OAT = "set_outside_temperature"
SERVICE_SET_SB_TEMP = "set_setback_temperature"
TRANSLATE_SOURCE = {
gw_vars.BOILER: "Boiler",
gw_vars.OTGW: None,
gw_vars.THERMOSTAT: "Thermostat",
}
UNIT_KW = "kW"
UNIT_L_MIN = f"L/{TIME_MINUTES}"
BINARY_SENSOR_INFO = {
# [device_class, friendly_name format, [status source, ...]]
gw_vars.DATA_MASTER_CH_ENABLED: [
None,
"Thermostat Central Heating {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_DHW_ENABLED: [
None,
"Thermostat Hot Water {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_COOLING_ENABLED: [
None,
"Thermostat Cooling {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_OTC_ENABLED: [
None,
"Thermostat Outside Temperature Correction {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_CH2_ENABLED: [
None,
"Thermostat Central Heating 2 {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_FAULT_IND: [
DEVICE_CLASS_PROBLEM,
"Boiler Fault {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_CH_ACTIVE: [
DEVICE_CLASS_HEAT,
"Boiler Central Heating {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_DHW_ACTIVE: [
DEVICE_CLASS_HEAT,
"Boiler Hot Water {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_FLAME_ON: [
DEVICE_CLASS_HEAT,
"Boiler Flame {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_COOLING_ACTIVE: [
DEVICE_CLASS_COLD,
"Boiler Cooling {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_CH2_ACTIVE: [
DEVICE_CLASS_HEAT,
"Boiler Central Heating 2 {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_DIAG_IND: [
DEVICE_CLASS_PROBLEM,
"Boiler Diagnostics {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_DHW_PRESENT: [
None,
"Boiler Hot Water Present {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_CONTROL_TYPE: [
None,
"Boiler Control Type {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_COOLING_SUPPORTED: [
None,
"Boiler Cooling Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_DHW_CONFIG: [
None,
"Boiler Hot Water Configuration {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_MASTER_LOW_OFF_PUMP: [
None,
"Boiler Pump Commands Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_CH2_PRESENT: [
None,
"Boiler Central Heating 2 Present {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_SERVICE_REQ: [
DEVICE_CLASS_PROBLEM,
"Boiler Service Required {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_REMOTE_RESET: [
None,
"Boiler Remote Reset Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_LOW_WATER_PRESS: [
DEVICE_CLASS_PROBLEM,
"Boiler Low Water Pressure {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_GAS_FAULT: [
DEVICE_CLASS_PROBLEM,
"Boiler Gas Fault {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_AIR_PRESS_FAULT: [
DEVICE_CLASS_PROBLEM,
"Boiler Air Pressure Fault {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_WATER_OVERTEMP: [
DEVICE_CLASS_PROBLEM,
"Boiler Water Overtemperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_REMOTE_TRANSFER_DHW: [
None,
"Remote Hot Water Setpoint Transfer Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_REMOTE_TRANSFER_MAX_CH: [
None,
"Remote Maximum Central Heating Setpoint Write Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_REMOTE_RW_DHW: [
None,
"Remote Hot Water Setpoint Write Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_REMOTE_RW_MAX_CH: [
None,
"Remote Central Heating Setpoint Write Support {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_ROVRD_MAN_PRIO: [
None,
"Remote Override Manual Change Priority {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_ROVRD_AUTO_PRIO: [
None,
"Remote Override Program Change Priority {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.OTGW_GPIO_A_STATE: [None, "Gateway GPIO A {}", [gw_vars.OTGW]],
gw_vars.OTGW_GPIO_B_STATE: [None, "Gateway GPIO B {}", [gw_vars.OTGW]],
gw_vars.OTGW_IGNORE_TRANSITIONS: [
None,
"Gateway Ignore Transitions {}",
[gw_vars.OTGW],
],
gw_vars.OTGW_OVRD_HB: [None, "Gateway Override High Byte {}", [gw_vars.OTGW]],
}
SENSOR_INFO = {
# [device_class, unit, friendly_name, [status source, ...]]
gw_vars.DATA_CONTROL_SETPOINT: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Control Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_MEMBERID: [
None,
None,
"Thermostat Member ID {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_MEMBERID: [
None,
None,
"Boiler Member ID {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_OEM_FAULT: [
None,
None,
"Boiler OEM Fault Code {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_COOLING_CONTROL: [
None,
PERCENTAGE,
"Cooling Control Signal {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_CONTROL_SETPOINT_2: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Control Setpoint 2 {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_ROOM_SETPOINT_OVRD: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Room Setpoint Override {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD: [
None,
PERCENTAGE,
"Boiler Maximum Relative Modulation {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_MAX_CAPACITY: [
None,
UNIT_KW,
"Boiler Maximum Capacity {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL: [
None,
PERCENTAGE,
"Boiler Minimum Modulation Level {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_ROOM_SETPOINT: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Room Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_REL_MOD_LEVEL: [
None,
PERCENTAGE,
"Relative Modulation Level {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_CH_WATER_PRESS: [
None,
PRESSURE_BAR,
"Central Heating Water Pressure {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_FLOW_RATE: [
None,
UNIT_L_MIN,
"Hot Water Flow Rate {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_ROOM_SETPOINT_2: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Room Setpoint 2 {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_ROOM_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Room Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_CH_WATER_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Central Heating Water Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Hot Water Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_OUTSIDE_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Outside Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_RETURN_WATER_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Return Water Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SOLAR_STORAGE_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Solar Storage Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SOLAR_COLL_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Solar Collector Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_CH_WATER_TEMP_2: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Central Heating 2 Water Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_TEMP_2: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Hot Water 2 Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_EXHAUST_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Exhaust Temperature {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_DHW_MAX_SETP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Hot Water Maximum Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_DHW_MIN_SETP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Hot Water Minimum Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_CH_MAX_SETP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Boiler Maximum Central Heating Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_CH_MIN_SETP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Boiler Minimum Central Heating Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_SETPOINT: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Hot Water Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MAX_CH_SETPOINT: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Maximum Central Heating Setpoint {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_OEM_DIAG: [
None,
None,
"OEM Diagnostic Code {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_TOTAL_BURNER_STARTS: [
None,
None,
"Total Burner Starts {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_CH_PUMP_STARTS: [
None,
None,
"Central Heating Pump Starts {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_PUMP_STARTS: [
None,
None,
"Hot Water Pump Starts {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_BURNER_STARTS: [
None,
None,
"Hot Water Burner Starts {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_TOTAL_BURNER_HOURS: [
None,
TIME_HOURS,
"Total Burner Hours {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_CH_PUMP_HOURS: [
None,
TIME_HOURS,
"Central Heating Pump Hours {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_PUMP_HOURS: [
None,
TIME_HOURS,
"Hot Water Pump Hours {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_DHW_BURNER_HOURS: [
None,
TIME_HOURS,
"Hot Water Burner Hours {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_OT_VERSION: [
None,
None,
"Thermostat OpenTherm Version {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_OT_VERSION: [
None,
None,
"Boiler OpenTherm Version {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_PRODUCT_TYPE: [
None,
None,
"Thermostat Product Type {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_MASTER_PRODUCT_VERSION: [
None,
None,
"Thermostat Product Version {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_PRODUCT_TYPE: [
None,
None,
"Boiler Product Type {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.DATA_SLAVE_PRODUCT_VERSION: [
None,
None,
"Boiler Product Version {}",
[gw_vars.BOILER, gw_vars.THERMOSTAT],
],
gw_vars.OTGW_MODE: [None, None, "Gateway/Monitor Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_DHW_OVRD: [
None,
None,
"Gateway Hot Water Override Mode {}",
[gw_vars.OTGW],
],
gw_vars.OTGW_ABOUT: [None, None, "Gateway Firmware Version {}", [gw_vars.OTGW]],
gw_vars.OTGW_BUILD: [None, None, "Gateway Firmware Build {}", [gw_vars.OTGW]],
gw_vars.OTGW_CLOCKMHZ: [None, None, "Gateway Clock Speed {}", [gw_vars.OTGW]],
gw_vars.OTGW_LED_A: [None, None, "Gateway LED A Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_LED_B: [None, None, "Gateway LED B Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_LED_C: [None, None, "Gateway LED C Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_LED_D: [None, None, "Gateway LED D Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_LED_E: [None, None, "Gateway LED E Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_LED_F: [None, None, "Gateway LED F Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_GPIO_A: [None, None, "Gateway GPIO A Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_GPIO_B: [None, None, "Gateway GPIO B Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_SB_TEMP: [
DEVICE_CLASS_TEMPERATURE,
TEMP_CELSIUS,
"Gateway Setback Temperature {}",
[gw_vars.OTGW],
],
gw_vars.OTGW_SETP_OVRD_MODE: [
None,
None,
"Gateway Room Setpoint Override Mode {}",
[gw_vars.OTGW],
],
gw_vars.OTGW_SMART_PWR: [None, None, "Gateway Smart Power Mode {}", [gw_vars.OTGW]],
gw_vars.OTGW_THRM_DETECT: [
None,
None,
"Gateway Thermostat Detection {}",
[gw_vars.OTGW],
],
gw_vars.OTGW_VREF: [
None,
None,
"Gateway Reference Voltage Setting {}",
[gw_vars.OTGW],
],
}
DEPRECATED_BINARY_SENSOR_SOURCE_LOOKUP = {
gw_vars.DATA_MASTER_CH_ENABLED: gw_vars.THERMOSTAT,
gw_vars.DATA_MASTER_DHW_ENABLED: gw_vars.THERMOSTAT,
gw_vars.DATA_MASTER_OTC_ENABLED: gw_vars.THERMOSTAT,
gw_vars.DATA_MASTER_CH2_ENABLED: gw_vars.THERMOSTAT,
gw_vars.DATA_SLAVE_FAULT_IND: gw_vars.BOILER,
gw_vars.DATA_SLAVE_CH_ACTIVE: gw_vars.BOILER,
gw_vars.DATA_SLAVE_DHW_ACTIVE: gw_vars.BOILER,
gw_vars.DATA_SLAVE_FLAME_ON: gw_vars.BOILER,
gw_vars.DATA_SLAVE_COOLING_ACTIVE: gw_vars.BOILER,
gw_vars.DATA_SLAVE_CH2_ACTIVE: gw_vars.BOILER,
gw_vars.DATA_SLAVE_DIAG_IND: gw_vars.BOILER,
gw_vars.DATA_SLAVE_DHW_PRESENT: gw_vars.BOILER,
gw_vars.DATA_SLAVE_CONTROL_TYPE: gw_vars.BOILER,
gw_vars.DATA_SLAVE_COOLING_SUPPORTED: gw_vars.BOILER,
gw_vars.DATA_SLAVE_DHW_CONFIG: gw_vars.BOILER,
gw_vars.DATA_SLAVE_MASTER_LOW_OFF_PUMP: gw_vars.BOILER,
gw_vars.DATA_SLAVE_CH2_PRESENT: gw_vars.BOILER,
gw_vars.DATA_SLAVE_SERVICE_REQ: gw_vars.BOILER,
gw_vars.DATA_SLAVE_REMOTE_RESET: gw_vars.BOILER,
gw_vars.DATA_SLAVE_LOW_WATER_PRESS: gw_vars.BOILER,
gw_vars.DATA_SLAVE_GAS_FAULT: gw_vars.BOILER,
gw_vars.DATA_SLAVE_AIR_PRESS_FAULT: gw_vars.BOILER,
gw_vars.DATA_SLAVE_WATER_OVERTEMP: gw_vars.BOILER,
gw_vars.DATA_REMOTE_TRANSFER_DHW: gw_vars.BOILER,
gw_vars.DATA_REMOTE_TRANSFER_MAX_CH: gw_vars.BOILER,
gw_vars.DATA_REMOTE_RW_DHW: gw_vars.BOILER,
gw_vars.DATA_REMOTE_RW_MAX_CH: gw_vars.BOILER,
gw_vars.DATA_ROVRD_MAN_PRIO: gw_vars.THERMOSTAT,
gw_vars.DATA_ROVRD_AUTO_PRIO: gw_vars.THERMOSTAT,
gw_vars.OTGW_GPIO_A_STATE: gw_vars.OTGW,
gw_vars.OTGW_GPIO_B_STATE: gw_vars.OTGW,
gw_vars.OTGW_IGNORE_TRANSITIONS: gw_vars.OTGW,
gw_vars.OTGW_OVRD_HB: gw_vars.OTGW,
}
DEPRECATED_SENSOR_SOURCE_LOOKUP = {
gw_vars.DATA_CONTROL_SETPOINT: gw_vars.BOILER,
gw_vars.DATA_MASTER_MEMBERID: gw_vars.THERMOSTAT,
gw_vars.DATA_SLAVE_MEMBERID: gw_vars.BOILER,
gw_vars.DATA_SLAVE_OEM_FAULT: gw_vars.BOILER,
gw_vars.DATA_COOLING_CONTROL: gw_vars.BOILER,
gw_vars.DATA_CONTROL_SETPOINT_2: gw_vars.BOILER,
gw_vars.DATA_ROOM_SETPOINT_OVRD: gw_vars.THERMOSTAT,
gw_vars.DATA_SLAVE_MAX_RELATIVE_MOD: gw_vars.BOILER,
gw_vars.DATA_SLAVE_MAX_CAPACITY: gw_vars.BOILER,
gw_vars.DATA_SLAVE_MIN_MOD_LEVEL: gw_vars.BOILER,
gw_vars.DATA_ROOM_SETPOINT: gw_vars.THERMOSTAT,
gw_vars.DATA_REL_MOD_LEVEL: gw_vars.BOILER,
gw_vars.DATA_CH_WATER_PRESS: gw_vars.BOILER,
gw_vars.DATA_DHW_FLOW_RATE: gw_vars.BOILER,
gw_vars.DATA_ROOM_SETPOINT_2: gw_vars.THERMOSTAT,
gw_vars.DATA_ROOM_TEMP: gw_vars.THERMOSTAT,
gw_vars.DATA_CH_WATER_TEMP: gw_vars.BOILER,
gw_vars.DATA_DHW_TEMP: gw_vars.BOILER,
gw_vars.DATA_OUTSIDE_TEMP: gw_vars.THERMOSTAT,
gw_vars.DATA_RETURN_WATER_TEMP: gw_vars.BOILER,
gw_vars.DATA_SOLAR_STORAGE_TEMP: gw_vars.BOILER,
gw_vars.DATA_SOLAR_COLL_TEMP: gw_vars.BOILER,
gw_vars.DATA_CH_WATER_TEMP_2: gw_vars.BOILER,
gw_vars.DATA_DHW_TEMP_2: gw_vars.BOILER,
gw_vars.DATA_EXHAUST_TEMP: gw_vars.BOILER,
gw_vars.DATA_SLAVE_DHW_MAX_SETP: gw_vars.BOILER,
gw_vars.DATA_SLAVE_DHW_MIN_SETP: gw_vars.BOILER,
gw_vars.DATA_SLAVE_CH_MAX_SETP: gw_vars.BOILER,
gw_vars.DATA_SLAVE_CH_MIN_SETP: gw_vars.BOILER,
gw_vars.DATA_DHW_SETPOINT: gw_vars.BOILER,
gw_vars.DATA_MAX_CH_SETPOINT: gw_vars.BOILER,
gw_vars.DATA_OEM_DIAG: gw_vars.BOILER,
gw_vars.DATA_TOTAL_BURNER_STARTS: gw_vars.BOILER,
gw_vars.DATA_CH_PUMP_STARTS: gw_vars.BOILER,
gw_vars.DATA_DHW_PUMP_STARTS: gw_vars.BOILER,
gw_vars.DATA_DHW_BURNER_STARTS: gw_vars.BOILER,
gw_vars.DATA_TOTAL_BURNER_HOURS: gw_vars.BOILER,
gw_vars.DATA_CH_PUMP_HOURS: gw_vars.BOILER,
gw_vars.DATA_DHW_PUMP_HOURS: gw_vars.BOILER,
gw_vars.DATA_DHW_BURNER_HOURS: gw_vars.BOILER,
gw_vars.DATA_MASTER_OT_VERSION: gw_vars.THERMOSTAT,
gw_vars.DATA_SLAVE_OT_VERSION: gw_vars.BOILER,
gw_vars.DATA_MASTER_PRODUCT_TYPE: gw_vars.THERMOSTAT,
gw_vars.DATA_MASTER_PRODUCT_VERSION: gw_vars.THERMOSTAT,
gw_vars.DATA_SLAVE_PRODUCT_TYPE: gw_vars.BOILER,
gw_vars.DATA_SLAVE_PRODUCT_VERSION: gw_vars.BOILER,
gw_vars.OTGW_MODE: gw_vars.OTGW,
gw_vars.OTGW_DHW_OVRD: gw_vars.OTGW,
gw_vars.OTGW_ABOUT: gw_vars.OTGW,
gw_vars.OTGW_BUILD: gw_vars.OTGW,
gw_vars.OTGW_CLOCKMHZ: gw_vars.OTGW,
gw_vars.OTGW_LED_A: gw_vars.OTGW,
gw_vars.OTGW_LED_B: gw_vars.OTGW,
gw_vars.OTGW_LED_C: gw_vars.OTGW,
gw_vars.OTGW_LED_D: gw_vars.OTGW,
gw_vars.OTGW_LED_E: gw_vars.OTGW,
gw_vars.OTGW_LED_F: gw_vars.OTGW,
gw_vars.OTGW_GPIO_A: gw_vars.OTGW,
gw_vars.OTGW_GPIO_B: gw_vars.OTGW,
gw_vars.OTGW_SB_TEMP: gw_vars.OTGW,
gw_vars.OTGW_SETP_OVRD_MODE: gw_vars.OTGW,
gw_vars.OTGW_SMART_PWR: gw_vars.OTGW,
gw_vars.OTGW_THRM_DETECT: gw_vars.OTGW,
gw_vars.OTGW_VREF: gw_vars.OTGW,
}