core/homeassistant/components/sensor/device_trigger.py

193 lines
6.1 KiB
Python

"""Provides device triggers for sensors."""
import voluptuous as vol
from homeassistant.components.device_automation import TRIGGER_BASE_SCHEMA
from homeassistant.components.device_automation.exceptions import (
InvalidDeviceAutomationConfig,
)
from homeassistant.components.homeassistant.triggers import (
numeric_state as numeric_state_trigger,
)
from homeassistant.const import (
ATTR_DEVICE_CLASS,
ATTR_UNIT_OF_MEASUREMENT,
CONF_ABOVE,
CONF_BELOW,
CONF_ENTITY_ID,
CONF_FOR,
CONF_TYPE,
DEVICE_CLASS_BATTERY,
DEVICE_CLASS_CO,
DEVICE_CLASS_CO2,
DEVICE_CLASS_CURRENT,
DEVICE_CLASS_ENERGY,
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_ILLUMINANCE,
DEVICE_CLASS_POWER,
DEVICE_CLASS_POWER_FACTOR,
DEVICE_CLASS_PRESSURE,
DEVICE_CLASS_SIGNAL_STRENGTH,
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_VOLTAGE,
)
from homeassistant.helpers import config_validation as cv
from homeassistant.helpers.entity_registry import async_entries_for_device
from . import DOMAIN
# mypy: allow-untyped-defs, no-check-untyped-defs
DEVICE_CLASS_NONE = "none"
CONF_BATTERY_LEVEL = "battery_level"
CONF_CO = "carbon_monoxide"
CONF_CO2 = "carbon_dioxide"
CONF_CURRENT = "current"
CONF_ENERGY = "energy"
CONF_HUMIDITY = "humidity"
CONF_ILLUMINANCE = "illuminance"
CONF_POWER = "power"
CONF_POWER_FACTOR = "power_factor"
CONF_PRESSURE = "pressure"
CONF_SIGNAL_STRENGTH = "signal_strength"
CONF_TEMPERATURE = "temperature"
CONF_VOLTAGE = "voltage"
CONF_VALUE = "value"
ENTITY_TRIGGERS = {
DEVICE_CLASS_BATTERY: [{CONF_TYPE: CONF_BATTERY_LEVEL}],
DEVICE_CLASS_CO: [{CONF_TYPE: CONF_CO}],
DEVICE_CLASS_CO2: [{CONF_TYPE: CONF_CO2}],
DEVICE_CLASS_CURRENT: [{CONF_TYPE: CONF_CURRENT}],
DEVICE_CLASS_ENERGY: [{CONF_TYPE: CONF_ENERGY}],
DEVICE_CLASS_HUMIDITY: [{CONF_TYPE: CONF_HUMIDITY}],
DEVICE_CLASS_ILLUMINANCE: [{CONF_TYPE: CONF_ILLUMINANCE}],
DEVICE_CLASS_POWER: [{CONF_TYPE: CONF_POWER}],
DEVICE_CLASS_POWER_FACTOR: [{CONF_TYPE: CONF_POWER_FACTOR}],
DEVICE_CLASS_PRESSURE: [{CONF_TYPE: CONF_PRESSURE}],
DEVICE_CLASS_SIGNAL_STRENGTH: [{CONF_TYPE: CONF_SIGNAL_STRENGTH}],
DEVICE_CLASS_TEMPERATURE: [{CONF_TYPE: CONF_TEMPERATURE}],
DEVICE_CLASS_VOLTAGE: [{CONF_TYPE: CONF_VOLTAGE}],
DEVICE_CLASS_NONE: [{CONF_TYPE: CONF_VALUE}],
}
TRIGGER_SCHEMA = vol.All(
TRIGGER_BASE_SCHEMA.extend(
{
vol.Required(CONF_ENTITY_ID): cv.entity_id,
vol.Required(CONF_TYPE): vol.In(
[
CONF_BATTERY_LEVEL,
CONF_CO,
CONF_CO2,
CONF_CURRENT,
CONF_ENERGY,
CONF_HUMIDITY,
CONF_ILLUMINANCE,
CONF_POWER,
CONF_POWER_FACTOR,
CONF_PRESSURE,
CONF_SIGNAL_STRENGTH,
CONF_TEMPERATURE,
CONF_VOLTAGE,
CONF_VALUE,
]
),
vol.Optional(CONF_BELOW): vol.Any(vol.Coerce(float)),
vol.Optional(CONF_ABOVE): vol.Any(vol.Coerce(float)),
vol.Optional(CONF_FOR): cv.positive_time_period_dict,
}
),
cv.has_at_least_one_key(CONF_BELOW, CONF_ABOVE),
)
async def async_attach_trigger(hass, config, action, automation_info):
"""Listen for state changes based on configuration."""
numeric_state_config = {
numeric_state_trigger.CONF_PLATFORM: "numeric_state",
numeric_state_trigger.CONF_ENTITY_ID: config[CONF_ENTITY_ID],
}
if CONF_ABOVE in config:
numeric_state_config[numeric_state_trigger.CONF_ABOVE] = config[CONF_ABOVE]
if CONF_BELOW in config:
numeric_state_config[numeric_state_trigger.CONF_BELOW] = config[CONF_BELOW]
if CONF_FOR in config:
numeric_state_config[CONF_FOR] = config[CONF_FOR]
numeric_state_config = numeric_state_trigger.TRIGGER_SCHEMA(numeric_state_config)
return await numeric_state_trigger.async_attach_trigger(
hass, numeric_state_config, action, automation_info, platform_type="device"
)
async def async_get_triggers(hass, device_id):
"""List device triggers."""
triggers = []
entity_registry = await hass.helpers.entity_registry.async_get_registry()
entries = [
entry
for entry in async_entries_for_device(entity_registry, device_id)
if entry.domain == DOMAIN
]
for entry in entries:
device_class = DEVICE_CLASS_NONE
state = hass.states.get(entry.entity_id)
unit_of_measurement = (
state.attributes.get(ATTR_UNIT_OF_MEASUREMENT) if state else None
)
if not state or not unit_of_measurement:
continue
if ATTR_DEVICE_CLASS in state.attributes:
device_class = state.attributes[ATTR_DEVICE_CLASS]
templates = ENTITY_TRIGGERS.get(
device_class, ENTITY_TRIGGERS[DEVICE_CLASS_NONE]
)
triggers.extend(
{
**automation,
"platform": "device",
"device_id": device_id,
"entity_id": entry.entity_id,
"domain": DOMAIN,
}
for automation in templates
)
return triggers
async def async_get_trigger_capabilities(hass, config):
"""List trigger capabilities."""
state = hass.states.get(config[CONF_ENTITY_ID])
unit_of_measurement = (
state.attributes.get(ATTR_UNIT_OF_MEASUREMENT) if state else None
)
if not state or not unit_of_measurement:
raise InvalidDeviceAutomationConfig(
"No state or unit of measurement found for "
f"trigger entity {config[CONF_ENTITY_ID]}"
)
return {
"extra_fields": vol.Schema(
{
vol.Optional(
CONF_ABOVE, description={"suffix": unit_of_measurement}
): vol.Coerce(float),
vol.Optional(
CONF_BELOW, description={"suffix": unit_of_measurement}
): vol.Coerce(float),
vol.Optional(CONF_FOR): cv.positive_time_period_dict,
}
)
}