"""Binary sensors for the Elexa Guardian integration."""
from __future__ import annotations
from dataclasses import dataclass
from homeassistant.components.binary_sensor import (
DOMAIN as BINARY_SENSOR_DOMAIN,
BinarySensorDeviceClass,
BinarySensorEntity,
BinarySensorEntityDescription,
)
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import EntityCategory
from homeassistant.core import HomeAssistant, callback
from homeassistant.helpers.dispatcher import async_dispatcher_connect
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from . import (
GuardianData,
PairedSensorEntity,
ValveControllerEntity,
ValveControllerEntityDescription,
)
from .const import (
API_SYSTEM_ONBOARD_SENSOR_STATUS,
CONF_UID,
DOMAIN,
SIGNAL_PAIRED_SENSOR_COORDINATOR_ADDED,
)
from .util import (
EntityDomainReplacementStrategy,
GuardianDataUpdateCoordinator,
async_finish_entity_domain_replacements,
)
ATTR_CONNECTED_CLIENTS = "connected_clients"
SENSOR_KIND_LEAK_DETECTED = "leak_detected"
SENSOR_KIND_MOVED = "moved"
@dataclass
class ValveControllerBinarySensorDescription(
BinarySensorEntityDescription, ValveControllerEntityDescription
):
"""Describe a Guardian valve controller binary sensor."""
PAIRED_SENSOR_DESCRIPTIONS = (
BinarySensorEntityDescription(
key=SENSOR_KIND_LEAK_DETECTED,
name="Leak detected",
device_class=BinarySensorDeviceClass.MOISTURE,
),
BinarySensorEntityDescription(
key=SENSOR_KIND_MOVED,
name="Recently moved",
device_class=BinarySensorDeviceClass.MOVING,
entity_category=EntityCategory.DIAGNOSTIC,
),
)
VALVE_CONTROLLER_DESCRIPTIONS = (
ValveControllerBinarySensorDescription(
key=SENSOR_KIND_LEAK_DETECTED,
name="Leak detected",
device_class=BinarySensorDeviceClass.MOISTURE,
api_category=API_SYSTEM_ONBOARD_SENSOR_STATUS,
),
)
async def async_setup_entry(
hass: HomeAssistant, entry: ConfigEntry, async_add_entities: AddEntitiesCallback
) -> None:
"""Set up Guardian switches based on a config entry."""
data: GuardianData = hass.data[DOMAIN][entry.entry_id]
uid = entry.data[CONF_UID]
async_finish_entity_domain_replacements(
hass,
entry,
(
EntityDomainReplacementStrategy(
BINARY_SENSOR_DOMAIN,
f"{uid}_ap_enabled",
f"switch.guardian_valve_controller_{uid}_onboard_ap",
"2022.12.0",
remove_old_entity=True,
),
),
)
@callback
def add_new_paired_sensor(uid: str) -> None:
"""Add a new paired sensor."""
async_add_entities(
PairedSensorBinarySensor(
entry, data.paired_sensor_manager.coordinators[uid], description
)
for description in PAIRED_SENSOR_DESCRIPTIONS
)
# Handle adding paired sensors after HASS startup:
entry.async_on_unload(
async_dispatcher_connect(
hass,
SIGNAL_PAIRED_SENSOR_COORDINATOR_ADDED.format(entry.data[CONF_UID]),
add_new_paired_sensor,
)
)
# Add all valve controller-specific binary sensors:
sensors: list[PairedSensorBinarySensor | ValveControllerBinarySensor] = [
ValveControllerBinarySensor(
entry, data.valve_controller_coordinators, description
)
for description in VALVE_CONTROLLER_DESCRIPTIONS
]
# Add all paired sensor-specific binary sensors:
sensors.extend(
[
PairedSensorBinarySensor(entry, coordinator, description)
for coordinator in data.paired_sensor_manager.coordinators.values()
for description in PAIRED_SENSOR_DESCRIPTIONS
]
)
async_add_entities(sensors)
class PairedSensorBinarySensor(PairedSensorEntity, BinarySensorEntity):
"""Define a binary sensor related to a Guardian valve controller."""
entity_description: BinarySensorEntityDescription
def __init__(
self,
entry: ConfigEntry,
coordinator: GuardianDataUpdateCoordinator,
description: BinarySensorEntityDescription,
) -> None:
"""Initialize."""
super().__init__(entry, coordinator, description)
self._attr_is_on = True
@callback
def _async_update_from_latest_data(self) -> None:
"""Update the entity's underlying data."""
if self.entity_description.key == SENSOR_KIND_LEAK_DETECTED:
self._attr_is_on = self.coordinator.data["wet"]
elif self.entity_description.key == SENSOR_KIND_MOVED:
self._attr_is_on = self.coordinator.data["moved"]
class ValveControllerBinarySensor(ValveControllerEntity, BinarySensorEntity):
"""Define a binary sensor related to a Guardian valve controller."""
entity_description: ValveControllerBinarySensorDescription
def __init__(
self,
entry: ConfigEntry,
coordinators: dict[str, GuardianDataUpdateCoordinator],
description: ValveControllerBinarySensorDescription,
) -> None:
"""Initialize."""
super().__init__(entry, coordinators, description)
self._attr_is_on = True
@callback
def _async_update_from_latest_data(self) -> None:
"""Update the entity."""
if self.entity_description.key == SENSOR_KIND_LEAK_DETECTED:
self._attr_is_on = self.coordinator.data["wet"]