143 lines
4.7 KiB
Python
143 lines
4.7 KiB
Python
"""Z-Wave workarounds."""
|
|
from . import const
|
|
|
|
# Manufacturers
|
|
FIBARO = 0x010f
|
|
GE = 0x0063
|
|
PHILIO = 0x013c
|
|
SOMFY = 0x0047
|
|
WENZHOU = 0x0118
|
|
VIZIA = 0x001D
|
|
|
|
# Product IDs
|
|
GE_FAN_CONTROLLER_12730 = 0x3034
|
|
GE_FAN_CONTROLLER_14287 = 0x3131
|
|
JASCO_FAN_CONTROLLER_14314 = 0x3138
|
|
PHILIO_SLIM_SENSOR = 0x0002
|
|
PHILIO_3_IN_1_SENSOR_GEN_4 = 0x000d
|
|
PHILIO_PAN07 = 0x0005
|
|
VIZIA_FAN_CONTROLLER_VRF01 = 0x0334
|
|
|
|
# Product Types
|
|
FGFS101_FLOOD_SENSOR_TYPE = 0x0b00
|
|
FGRM222_SHUTTER2 = 0x0301
|
|
FGR222_SHUTTER2 = 0x0302
|
|
GE_DIMMER = 0x4944
|
|
PHILIO_SWITCH = 0x0001
|
|
PHILIO_SENSOR = 0x0002
|
|
SOMFY_ZRTSI = 0x5a52
|
|
VIZIA_DIMMER = 0x1001
|
|
|
|
# Mapping devices
|
|
PHILIO_SLIM_SENSOR_MOTION_MTII = (PHILIO, PHILIO_SENSOR, PHILIO_SLIM_SENSOR, 0)
|
|
PHILIO_3_IN_1_SENSOR_GEN_4_MOTION_MTII = (
|
|
PHILIO, PHILIO_SENSOR, PHILIO_3_IN_1_SENSOR_GEN_4, 0)
|
|
PHILIO_PAN07_MTI_INSTANCE = (PHILIO, PHILIO_SWITCH, PHILIO_PAN07, 1)
|
|
WENZHOU_SLIM_SENSOR_MOTION_MTII = (
|
|
WENZHOU, PHILIO_SENSOR, PHILIO_SLIM_SENSOR, 0)
|
|
|
|
# Workarounds
|
|
WORKAROUND_NO_OFF_EVENT = 'trigger_no_off_event'
|
|
WORKAROUND_NO_POSITION = 'workaround_no_position'
|
|
WORKAROUND_REFRESH_NODE_ON_UPDATE = 'refresh_node_on_update'
|
|
WORKAROUND_IGNORE = 'workaround_ignore'
|
|
|
|
# List of workarounds by (manufacturer_id, product_type, product_id, index)
|
|
DEVICE_MAPPINGS_MTII = {
|
|
PHILIO_SLIM_SENSOR_MOTION_MTII: WORKAROUND_NO_OFF_EVENT,
|
|
PHILIO_3_IN_1_SENSOR_GEN_4_MOTION_MTII: WORKAROUND_NO_OFF_EVENT,
|
|
WENZHOU_SLIM_SENSOR_MOTION_MTII: WORKAROUND_NO_OFF_EVENT,
|
|
}
|
|
|
|
# List of workarounds by (manufacturer_id, product_type, product_id, instance)
|
|
DEVICE_MAPPINGS_MTI_INSTANCE = {
|
|
PHILIO_PAN07_MTI_INSTANCE: WORKAROUND_REFRESH_NODE_ON_UPDATE,
|
|
}
|
|
|
|
SOMFY_ZRTSI_CONTROLLER_MT = (SOMFY, SOMFY_ZRTSI)
|
|
|
|
# List of workarounds by (manufacturer_id, product_type)
|
|
DEVICE_MAPPINGS_MT = {
|
|
SOMFY_ZRTSI_CONTROLLER_MT: WORKAROUND_NO_POSITION,
|
|
}
|
|
|
|
# Component mapping devices
|
|
FIBARO_FGFS101_SENSOR_ALARM = (
|
|
FIBARO, FGFS101_FLOOD_SENSOR_TYPE, const.COMMAND_CLASS_SENSOR_ALARM)
|
|
FIBARO_FGRM222_BINARY = (
|
|
FIBARO, FGRM222_SHUTTER2, const.COMMAND_CLASS_SWITCH_BINARY)
|
|
FIBARO_FGR222_BINARY = (
|
|
FIBARO, FGR222_SHUTTER2, const.COMMAND_CLASS_SWITCH_BINARY)
|
|
GE_FAN_CONTROLLER_12730_MULTILEVEL = (
|
|
GE, GE_DIMMER, GE_FAN_CONTROLLER_12730,
|
|
const.COMMAND_CLASS_SWITCH_MULTILEVEL)
|
|
GE_FAN_CONTROLLER_14287_MULTILEVEL = (
|
|
GE, GE_DIMMER, GE_FAN_CONTROLLER_14287,
|
|
const.COMMAND_CLASS_SWITCH_MULTILEVEL)
|
|
JASCO_FAN_CONTROLLER_14314_MULTILEVEL = (
|
|
GE, GE_DIMMER, JASCO_FAN_CONTROLLER_14314,
|
|
const.COMMAND_CLASS_SWITCH_MULTILEVEL)
|
|
VIZIA_FAN_CONTROLLER_VRF01_MULTILEVEL = (
|
|
VIZIA, VIZIA_DIMMER, VIZIA_FAN_CONTROLLER_VRF01,
|
|
const.COMMAND_CLASS_SWITCH_MULTILEVEL)
|
|
|
|
# List of component workarounds by
|
|
# (manufacturer_id, product_type, command_class)
|
|
DEVICE_COMPONENT_MAPPING = {
|
|
FIBARO_FGFS101_SENSOR_ALARM: 'binary_sensor',
|
|
FIBARO_FGRM222_BINARY: WORKAROUND_IGNORE,
|
|
FIBARO_FGR222_BINARY: WORKAROUND_IGNORE,
|
|
}
|
|
|
|
# List of component workarounds by
|
|
# (manufacturer_id, product_type, product_id, command_class)
|
|
DEVICE_COMPONENT_MAPPING_MTI = {
|
|
GE_FAN_CONTROLLER_12730_MULTILEVEL: 'fan',
|
|
GE_FAN_CONTROLLER_14287_MULTILEVEL: 'fan',
|
|
JASCO_FAN_CONTROLLER_14314_MULTILEVEL: 'fan',
|
|
VIZIA_FAN_CONTROLLER_VRF01_MULTILEVEL: 'fan',
|
|
}
|
|
|
|
|
|
def get_device_component_mapping(value):
|
|
"""Get mapping of value to another component."""
|
|
if (value.node.manufacturer_id.strip() and
|
|
value.node.product_type.strip()):
|
|
manufacturer_id = int(value.node.manufacturer_id, 16)
|
|
product_type = int(value.node.product_type, 16)
|
|
product_id = int(value.node.product_id, 16)
|
|
result = DEVICE_COMPONENT_MAPPING.get(
|
|
(manufacturer_id, product_type, value.command_class))
|
|
if result:
|
|
return result
|
|
|
|
result = DEVICE_COMPONENT_MAPPING_MTI.get(
|
|
(manufacturer_id, product_type, product_id, value.command_class))
|
|
if result:
|
|
return result
|
|
|
|
return None
|
|
|
|
|
|
def get_device_mapping(value):
|
|
"""Get mapping of value to a workaround."""
|
|
if (value.node.manufacturer_id.strip() and
|
|
value.node.product_id.strip() and
|
|
value.node.product_type.strip()):
|
|
manufacturer_id = int(value.node.manufacturer_id, 16)
|
|
product_type = int(value.node.product_type, 16)
|
|
product_id = int(value.node.product_id, 16)
|
|
result = DEVICE_MAPPINGS_MTII.get(
|
|
(manufacturer_id, product_type, product_id, value.index))
|
|
if result:
|
|
return result
|
|
|
|
result = DEVICE_MAPPINGS_MTI_INSTANCE.get(
|
|
(manufacturer_id, product_type, product_id, value.instance))
|
|
if result:
|
|
return result
|
|
|
|
return DEVICE_MAPPINGS_MT.get((manufacturer_id, product_type))
|
|
|
|
return None
|