core/homeassistant/components/modbus/climate.py

245 lines
7.3 KiB
Python

"""Support for Generic Modbus Thermostats."""
import logging
import struct
import voluptuous as vol
from homeassistant.components.climate import PLATFORM_SCHEMA, ClimateDevice
from homeassistant.components.climate.const import (
HVAC_MODE_AUTO,
SUPPORT_TARGET_TEMPERATURE,
)
from homeassistant.const import (
ATTR_TEMPERATURE,
CONF_NAME,
CONF_SLAVE,
TEMP_CELSIUS,
TEMP_FAHRENHEIT,
)
import homeassistant.helpers.config_validation as cv
from . import CONF_HUB, DEFAULT_HUB, DOMAIN as MODBUS_DOMAIN
_LOGGER = logging.getLogger(__name__)
CONF_TARGET_TEMP = "target_temp_register"
CONF_CURRENT_TEMP = "current_temp_register"
CONF_DATA_TYPE = "data_type"
CONF_COUNT = "data_count"
CONF_PRECISION = "precision"
CONF_SCALE = "scale"
CONF_OFFSET = "offset"
CONF_UNIT = "temperature_unit"
DATA_TYPE_INT = "int"
DATA_TYPE_UINT = "uint"
DATA_TYPE_FLOAT = "float"
CONF_MAX_TEMP = "max_temp"
CONF_MIN_TEMP = "min_temp"
CONF_STEP = "temp_step"
SUPPORT_FLAGS = SUPPORT_TARGET_TEMPERATURE
HVAC_MODES = [HVAC_MODE_AUTO]
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
{
vol.Required(CONF_CURRENT_TEMP): cv.positive_int,
vol.Required(CONF_NAME): cv.string,
vol.Required(CONF_SLAVE): cv.positive_int,
vol.Required(CONF_TARGET_TEMP): cv.positive_int,
vol.Optional(CONF_COUNT, default=2): cv.positive_int,
vol.Optional(CONF_DATA_TYPE, default=DATA_TYPE_FLOAT): vol.In(
[DATA_TYPE_INT, DATA_TYPE_UINT, DATA_TYPE_FLOAT]
),
vol.Optional(CONF_HUB, default=DEFAULT_HUB): cv.string,
vol.Optional(CONF_PRECISION, default=1): cv.positive_int,
vol.Optional(CONF_SCALE, default=1): vol.Coerce(float),
vol.Optional(CONF_OFFSET, default=0): vol.Coerce(float),
vol.Optional(CONF_MAX_TEMP, default=5): cv.positive_int,
vol.Optional(CONF_MIN_TEMP, default=35): cv.positive_int,
vol.Optional(CONF_STEP, default=0.5): vol.Coerce(float),
vol.Optional(CONF_UNIT, default="C"): cv.string,
}
)
def setup_platform(hass, config, add_entities, discovery_info=None):
"""Set up the Modbus Thermostat Platform."""
name = config.get(CONF_NAME)
modbus_slave = config.get(CONF_SLAVE)
target_temp_register = config.get(CONF_TARGET_TEMP)
current_temp_register = config.get(CONF_CURRENT_TEMP)
data_type = config.get(CONF_DATA_TYPE)
count = config.get(CONF_COUNT)
precision = config.get(CONF_PRECISION)
scale = config.get(CONF_SCALE)
offset = config.get(CONF_OFFSET)
unit = config.get(CONF_UNIT)
max_temp = config.get(CONF_MAX_TEMP)
min_temp = config.get(CONF_MIN_TEMP)
temp_step = config.get(CONF_STEP)
hub_name = config.get(CONF_HUB)
hub = hass.data[MODBUS_DOMAIN][hub_name]
add_entities(
[
ModbusThermostat(
hub,
name,
modbus_slave,
target_temp_register,
current_temp_register,
data_type,
count,
precision,
scale,
offset,
unit,
max_temp,
min_temp,
temp_step,
)
],
True,
)
class ModbusThermostat(ClimateDevice):
"""Representation of a Modbus Thermostat."""
def __init__(
self,
hub,
name,
modbus_slave,
target_temp_register,
current_temp_register,
data_type,
count,
precision,
scale,
offset,
unit,
max_temp,
min_temp,
temp_step,
):
"""Initialize the unit."""
self._hub = hub
self._name = name
self._slave = modbus_slave
self._target_temperature_register = target_temp_register
self._current_temperature_register = current_temp_register
self._target_temperature = None
self._current_temperature = None
self._data_type = data_type
self._count = int(count)
self._precision = precision
self._scale = scale
self._offset = offset
self._unit = unit
self._max_temp = max_temp
self._min_temp = min_temp
self._temp_step = temp_step
self._structure = ">f"
data_types = {
DATA_TYPE_INT: {1: "h", 2: "i", 4: "q"},
DATA_TYPE_UINT: {1: "H", 2: "I", 4: "Q"},
DATA_TYPE_FLOAT: {1: "e", 2: "f", 4: "d"},
}
self._structure = ">{}".format(data_types[self._data_type][self._count])
@property
def supported_features(self):
"""Return the list of supported features."""
return SUPPORT_FLAGS
def update(self):
"""Update Target & Current Temperature."""
self._target_temperature = self.read_register(self._target_temperature_register)
self._current_temperature = self.read_register(
self._current_temperature_register
)
@property
def hvac_mode(self):
"""Return the current HVAC mode."""
return HVAC_MODE_AUTO
@property
def hvac_modes(self):
"""Return the possible HVAC modes."""
return HVAC_MODES
@property
def name(self):
"""Return the name of the climate device."""
return self._name
@property
def current_temperature(self):
"""Return the current temperature."""
return self._current_temperature
@property
def target_temperature(self):
"""Return the target temperature."""
return self._target_temperature
@property
def temperature_unit(self):
"""Return the unit of measurement."""
return TEMP_FAHRENHEIT if self._unit == "F" else TEMP_CELSIUS
@property
def min_temp(self):
"""Return the minimum temperature."""
return self._min_temp
@property
def max_temp(self):
"""Return the maximum temperature."""
return self._max_temp
@property
def target_temperature_step(self):
"""Return the supported step of target temperature."""
return self._temp_step
def set_temperature(self, **kwargs):
"""Set new target temperature."""
target_temperature = int(
(kwargs.get(ATTR_TEMPERATURE) - self._offset) / self._scale
)
if target_temperature is None:
return
byte_string = struct.pack(self._structure, target_temperature)
register_value = struct.unpack(">h", byte_string[0:2])[0]
try:
self.write_register(self._target_temperature_register, register_value)
except AttributeError as ex:
_LOGGER.error(ex)
def read_register(self, register):
"""Read holding register using the Modbus hub slave."""
try:
result = self._hub.read_holding_registers(
self._slave, register, self._count
)
except AttributeError as ex:
_LOGGER.error(ex)
byte_string = b"".join(
[x.to_bytes(2, byteorder="big") for x in result.registers]
)
val = struct.unpack(self._structure, byte_string)[0]
register_value = format(
(self._scale * val) + self._offset, f".{self._precision}f"
)
register_value = float(register_value)
return register_value
def write_register(self, register, value):
"""Write register using the Modbus hub slave."""
self._hub.write_registers(self._slave, register, [value, 0])