"""Constants used in modbus integration.""" # configuration names CONF_BAUDRATE = "baudrate" CONF_BYTESIZE = "bytesize" CONF_HUB = "hub" CONF_PARITY = "parity" CONF_STOPBITS = "stopbits" CONF_REGISTER = "register" CONF_REGISTER_TYPE = "register_type" CONF_REGISTERS = "registers" CONF_REVERSE_ORDER = "reverse_order" CONF_SCALE = "scale" CONF_COUNT = "count" CONF_PRECISION = "precision" CONF_COILS = "coils" # integration names DEFAULT_HUB = "modbus_hub" MODBUS_DOMAIN = "modbus" # data types DATA_TYPE_CUSTOM = "custom" DATA_TYPE_FLOAT = "float" DATA_TYPE_INT = "int" DATA_TYPE_UINT = "uint" DATA_TYPE_STRING = "string" # call types CALL_TYPE_COIL = "coil" CALL_TYPE_DISCRETE = "discrete_input" CALL_TYPE_REGISTER_HOLDING = "holding" CALL_TYPE_REGISTER_INPUT = "input" # the following constants are TBD. # changing those in general causes a breaking change, because # the contents of configuration.yaml needs to be updated, # therefore they are left to a later date. # but kept here, with a reference to the file using them. # __init.py ATTR_ADDRESS = "address" ATTR_HUB = "hub" ATTR_UNIT = "unit" ATTR_VALUE = "value" SERVICE_WRITE_COIL = "write_coil" SERVICE_WRITE_REGISTER = "write_register" DEFAULT_SCAN_INTERVAL = 15 # seconds # binary_sensor.py CONF_INPUTS = "inputs" CONF_INPUT_TYPE = "input_type" CONF_BINARY_SENSORS = "binary_sensors" CONF_BINARY_SENSOR = "binary_sensor" # sensor.py # CONF_DATA_TYPE = "data_type" DEFAULT_STRUCT_FORMAT = { DATA_TYPE_INT: {1: "h", 2: "i", 4: "q"}, DATA_TYPE_UINT: {1: "H", 2: "I", 4: "Q"}, DATA_TYPE_FLOAT: {1: "e", 2: "f", 4: "d"}, } CONF_SENSOR = "sensor" CONF_SENSORS = "sensors" # switch.py CONF_STATE_OFF = "state_off" CONF_STATE_ON = "state_on" CONF_VERIFY_REGISTER = "verify_register" CONF_VERIFY_STATE = "verify_state" CONF_SWITCH = "switch" CONF_SWITCHES = "switches" # climate.py CONF_CLIMATES = "climates" CONF_CLIMATE = "climate" CONF_TARGET_TEMP = "target_temp_register" CONF_CURRENT_TEMP = "current_temp_register" CONF_CURRENT_TEMP_REGISTER_TYPE = "current_temp_register_type" CONF_DATA_TYPE = "data_type" CONF_DATA_COUNT = "data_count" CONF_UNIT = "temperature_unit" CONF_MAX_TEMP = "max_temp" CONF_MIN_TEMP = "min_temp" CONF_STEP = "temp_step" DEFAULT_STRUCTURE_PREFIX = ">f" DEFAULT_TEMP_UNIT = "C" # cover.py CONF_COVER = "cover" CONF_STATE_OPEN = "state_open" CONF_STATE_CLOSED = "state_closed" CONF_STATE_OPENING = "state_opening" CONF_STATE_CLOSING = "state_closing" CONF_STATUS_REGISTER = "status_register" CONF_STATUS_REGISTER_TYPE = "status_register_type" DEFAULT_SLAVE = 1