# Describes the format for available services for KEBA charging staitons request_data: description: > Request new data from the charging station. authorize: description: > Authorizes a charging process with the predefined RFID tag of the configuration file. deauthorize: description: > Deauthorizes the running charging process with the predefined RFID tag of the configuration file. set_energy: description: Sets the energy target after which the charging process stops. fields: energy: description: > The energy target to stop charging in kWh. Setting 0 disables the limit. example: 10.0 set_current: description: Sets the maximum current for charging processes. fields: current: description: > The maximum current used for the charging process in A. Allowed are values between 6 A and 63 A. Invalid values are discardedand the default is set to 6 A. The value is also depending on the DIP-switchsettings and the used cable of the charging station example: 16 enable: description: > Starts a charging process if charging station is authorized. disable: description: > Stops the charging process if charging station is authorized. set_failsafe: description: > Set the failsafe mode of the charging station. If all parameters are 0, the failsafe mode will be disabled. fields: failsafe_timeout: description: > Timeout in seconds after which the failsafe mode is triggered, if set_current was not executed during this time. example: 30 failsafe_fallback: description: > Fallback current in A to be set after timeout. example: 6 failsafe_persist: description: > If failsafe_persist is 0, the failsafe option is only until charging station reboot. If failsafe_persist is 1, the failsafe option will survive a reboot. example: 0