# Describes the format for available opentherm_gw services reset_gateway: name: Reset gateway description: Reset the OpenTherm Gateway. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: set_central_heating_ovrd: name: Set central heating override description: > Set the central heating override option on the gateway. When overriding the control setpoint (via a set_control_setpoint service call with a value other than 0), the gateway automatically enables the central heating override to start heating. This service can then be used to control the central heating override status. To return control of the central heating to the thermostat, call the set_control_setpoint service with temperature value 0. You will only need this if you are writing your own software thermostat. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: ch_override: name: Central heating override description: > The desired boolean value for the central heating override. required: true selector: boolean: set_clock: name: Set clock description: Set the clock and day of the week on the connected thermostat. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: date: name: Date description: Optional date from which the day of the week will be extracted. Defaults to today. example: "2018-10-23" selector: text: time: name: Time description: Optional time in 24h format which will be provided to the thermostat. Defaults to the current time. example: "19:34" selector: text: set_control_setpoint: name: Set control set point description: > Set the central heating control setpoint override on the gateway. You will only need this if you are writing your own software thermostat. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: temperature: name: Temperature description: > The central heating setpoint to set on the gateway. Values between 0 and 90 are accepted, but not all boilers support this range. A value of 0 disables the central heating setpoint override. required: true selector: number: min: 0 max: 90 step: 0.1 unit_of_measurement: '°' set_hot_water_ovrd: name: Set hot water override description: > Set the domestic hot water enable option on the gateway. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: dhw_override: name: Domestic hot water override description: > Control the domestic hot water enable option. If the boiler has been configured to let the room unit control when to keep a small amount of water preheated, this command can influence that. Value should be 0 or 1 to enable the override in off or on state, or "A" to disable the override. required: true example: "1" selector: text: set_hot_water_setpoint: name: Set hot water set point description: > Set the domestic hot water setpoint on the gateway. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: temperature: name: Temperature description: > The domestic hot water setpoint to set on the gateway. Not all boilers support this feature. Values between 0 and 90 are accepted, but not all boilers support this range. Check the values of the slave_dhw_min_setp and slave_dhw_max_setp sensors to see the supported range on your boiler. selector: number: min: 0 max: 90 step: 0.1 unit_of_measurement: '°' set_gpio_mode: name: Set gpio mode description: Change the function of the GPIO pins of the gateway. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: id: name: ID description: The ID of the GPIO pin. required: true selector: select: options: - 'A' - 'B' mode: name: Mode description: > Mode to set on the GPIO pin. Values 0 through 6 are accepted for both GPIOs, 7 is only accepted for GPIO "B". See https://www.home-assistant.io/integrations/opentherm_gw/#gpio-modes for an explanation of the values. required: true selector: number: min: 0 max: 7 set_led_mode: name: Set LED mode description: Change the function of the LEDs of the gateway. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: id: name: ID description: The ID of the LED. required: true selector: select: options: - 'A' - 'B' - 'C' - 'D' - 'E' - 'F' mode: name: Mode description: > The function to assign to the LED. See https://www.home-assistant.io/integrations/opentherm_gw/#led-modes for an explanation of the values. required: true selector: select: options: - 'B' - 'C' - 'E' - 'F' - 'H' - 'M' - 'O' - 'P' - 'R' - 'T' - 'W' - 'X' set_max_modulation: name: Set max modulation description: > Override the maximum relative modulation level. You will only need this if you are writing your own software thermostat. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: level: name: Level description: > The modulation level to provide to the gateway. Provide a value of -1 to clear the override and forward the value from the thermostat again. required: true selector: number: min: -1 max: 100 set_outside_temperature: name: Set outside temperature description: > Provide an outside temperature to the thermostat. If your thermostat is unable to display an outside temperature and does not support OTC (Outside Temperature Correction), this has no effect. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: temperature: name: Temperature description: > The temperature to provide to the thermostat. Values between -40.0 and 64.0 will be accepted, but not all thermostats can display the full range. Any value above 64.0 will clear a previously configured value (suggestion: 99) required: true selector: number: min: -40 max: 99 unit_of_measurement: "°" set_setback_temperature: name: Set setback temperature description: Configure the setback temperature to be used with the GPIO away mode function. fields: gateway_id: name: Gateway ID description: The gateway_id of the OpenTherm Gateway. required: true example: "opentherm_gateway" selector: text: temperature: name: Temperature description: The setback temperature to configure on the gateway. required: true selector: number: min: 0 max: 30 step: 0.1 unit_of_measurement: "°"