"""Constants for 1-Wire integration.""" from pi1wire import InvalidCRCException, UnsupportResponseException from pyownet.protocol import Error as ProtocolError from homeassistant.components.binary_sensor import DOMAIN as BINARY_SENSOR_DOMAIN from homeassistant.components.onewire.const import DOMAIN, PRESSURE_CBAR from homeassistant.components.sensor import DOMAIN as SENSOR_DOMAIN from homeassistant.components.switch import DOMAIN as SWITCH_DOMAIN from homeassistant.const import ( DEVICE_CLASS_CURRENT, DEVICE_CLASS_HUMIDITY, DEVICE_CLASS_ILLUMINANCE, DEVICE_CLASS_PRESSURE, DEVICE_CLASS_TEMPERATURE, DEVICE_CLASS_VOLTAGE, ELECTRICAL_CURRENT_AMPERE, LIGHT_LUX, PERCENTAGE, PRESSURE_MBAR, STATE_OFF, STATE_ON, TEMP_CELSIUS, VOLT, ) MOCK_OWPROXY_DEVICES = { "00.111111111111": { "inject_reads": [ b"", # read device type ], SENSOR_DOMAIN: [], }, "05.111111111111": { "inject_reads": [ b"DS2405", # read device type ], "device_info": { "identifiers": {(DOMAIN, "05.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2405", "name": "05.111111111111", }, SWITCH_DOMAIN: [ { "entity_id": "switch.05_111111111111_pio", "unique_id": "/05.111111111111/PIO", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, ], }, "10.111111111111": { "inject_reads": [ b"DS18S20", # read device type ], "device_info": { "identifiers": {(DOMAIN, "10.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS18S20", "name": "10.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.my_ds18b20_temperature", "unique_id": "/10.111111111111/temperature", "injected_value": b" 25.123", "result": "25.1", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "12.111111111111": { "inject_reads": [ b"DS2406", # read device type ], "device_info": { "identifiers": {(DOMAIN, "12.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2406", "name": "12.111111111111", }, BINARY_SENSOR_DOMAIN: [ { "entity_id": "binary_sensor.12_111111111111_sensed_a", "unique_id": "/12.111111111111/sensed.A", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.12_111111111111_sensed_b", "unique_id": "/12.111111111111/sensed.B", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, ], SENSOR_DOMAIN: [ { "entity_id": "sensor.12_111111111111_temperature", "unique_id": "/12.111111111111/TAI8570/temperature", "injected_value": b" 25.123", "result": "25.1", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, "disabled": True, }, { "entity_id": "sensor.12_111111111111_pressure", "unique_id": "/12.111111111111/TAI8570/pressure", "injected_value": b" 1025.123", "result": "1025.1", "unit": PRESSURE_MBAR, "class": DEVICE_CLASS_PRESSURE, "disabled": True, }, ], SWITCH_DOMAIN: [ { "entity_id": "switch.12_111111111111_pio_a", "unique_id": "/12.111111111111/PIO.A", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.12_111111111111_pio_b", "unique_id": "/12.111111111111/PIO.B", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.12_111111111111_latch_a", "unique_id": "/12.111111111111/latch.A", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.12_111111111111_latch_b", "unique_id": "/12.111111111111/latch.B", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, ], }, "1D.111111111111": { "inject_reads": [ b"DS2423", # read device type ], "device_info": { "identifiers": {(DOMAIN, "1D.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2423", "name": "1D.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.1d_111111111111_counter_a", "unique_id": "/1D.111111111111/counter.A", "injected_value": b" 251123", "result": "251123", "unit": "count", "class": None, }, { "entity_id": "sensor.1d_111111111111_counter_b", "unique_id": "/1D.111111111111/counter.B", "injected_value": b" 248125", "result": "248125", "unit": "count", "class": None, }, ], }, "1F.111111111111": { "inject_reads": [ b"DS2409", # read device type ], "device_info": { "identifiers": {(DOMAIN, "1F.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2409", "name": "1F.111111111111", }, "branches": { "aux": {}, "main": { "1D.111111111111": { "inject_reads": [ b"DS2423", # read device type ], "device_info": { "identifiers": {(DOMAIN, "1D.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2423", "name": "1D.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.1d_111111111111_counter_a", "device_file": "/1F.111111111111/main/1D.111111111111/counter.A", "unique_id": "/1D.111111111111/counter.A", "injected_value": b" 251123", "result": "251123", "unit": "count", "class": None, }, { "entity_id": "sensor.1d_111111111111_counter_b", "device_file": "/1F.111111111111/main/1D.111111111111/counter.B", "unique_id": "/1D.111111111111/counter.B", "injected_value": b" 248125", "result": "248125", "unit": "count", "class": None, }, ], }, }, }, }, "22.111111111111": { "inject_reads": [ b"DS1822", # read device type ], "device_info": { "identifiers": {(DOMAIN, "22.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS1822", "name": "22.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.22_111111111111_temperature", "unique_id": "/22.111111111111/temperature", "injected_value": ProtocolError, "result": "unknown", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "26.111111111111": { "inject_reads": [ b"DS2438", # read device type ], "device_info": { "identifiers": {(DOMAIN, "26.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2438", "name": "26.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.26_111111111111_temperature", "unique_id": "/26.111111111111/temperature", "injected_value": b" 25.123", "result": "25.1", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, { "entity_id": "sensor.26_111111111111_humidity", "unique_id": "/26.111111111111/humidity", "injected_value": b" 72.7563", "result": "72.8", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, "disabled": True, }, { "entity_id": "sensor.26_111111111111_humidity_hih3600", "unique_id": "/26.111111111111/HIH3600/humidity", "injected_value": b" 73.7563", "result": "73.8", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, "disabled": True, }, { "entity_id": "sensor.26_111111111111_humidity_hih4000", "unique_id": "/26.111111111111/HIH4000/humidity", "injected_value": b" 74.7563", "result": "74.8", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, "disabled": True, }, { "entity_id": "sensor.26_111111111111_humidity_hih5030", "unique_id": "/26.111111111111/HIH5030/humidity", "injected_value": b" 75.7563", "result": "75.8", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, "disabled": True, }, { "entity_id": "sensor.26_111111111111_humidity_htm1735", "unique_id": "/26.111111111111/HTM1735/humidity", "injected_value": ProtocolError, "result": "unknown", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, "disabled": True, }, { "entity_id": "sensor.26_111111111111_pressure", "unique_id": "/26.111111111111/B1-R1-A/pressure", "injected_value": b" 969.265", "result": "969.3", "unit": PRESSURE_MBAR, "class": DEVICE_CLASS_PRESSURE, "disabled": True, }, { "entity_id": "sensor.26_111111111111_illuminance", "unique_id": "/26.111111111111/S3-R1-A/illuminance", "injected_value": b" 65.8839", "result": "65.9", "unit": LIGHT_LUX, "class": DEVICE_CLASS_ILLUMINANCE, "disabled": True, }, { "entity_id": "sensor.26_111111111111_voltage_vad", "unique_id": "/26.111111111111/VAD", "injected_value": b" 2.97", "result": "3.0", "unit": VOLT, "class": DEVICE_CLASS_VOLTAGE, "disabled": True, }, { "entity_id": "sensor.26_111111111111_voltage_vdd", "unique_id": "/26.111111111111/VDD", "injected_value": b" 4.74", "result": "4.7", "unit": VOLT, "class": DEVICE_CLASS_VOLTAGE, "disabled": True, }, { "entity_id": "sensor.26_111111111111_current", "unique_id": "/26.111111111111/IAD", "injected_value": b" 1", "result": "1.0", "unit": ELECTRICAL_CURRENT_AMPERE, "class": DEVICE_CLASS_CURRENT, "disabled": True, }, ], }, "28.111111111111": { "inject_reads": [ b"DS18B20", # read device type ], "device_info": { "identifiers": {(DOMAIN, "28.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS18B20", "name": "28.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.28_111111111111_temperature", "unique_id": "/28.111111111111/temperature", "injected_value": b" 26.984", "result": "27.0", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "29.111111111111": { "inject_reads": [ b"DS2408", # read device type ], "device_info": { "identifiers": {(DOMAIN, "29.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS2408", "name": "29.111111111111", }, BINARY_SENSOR_DOMAIN: [ { "entity_id": "binary_sensor.29_111111111111_sensed_0", "unique_id": "/29.111111111111/sensed.0", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_1", "unique_id": "/29.111111111111/sensed.1", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_2", "unique_id": "/29.111111111111/sensed.2", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_3", "unique_id": "/29.111111111111/sensed.3", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_4", "unique_id": "/29.111111111111/sensed.4", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_5", "unique_id": "/29.111111111111/sensed.5", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_6", "unique_id": "/29.111111111111/sensed.6", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "binary_sensor.29_111111111111_sensed_7", "unique_id": "/29.111111111111/sensed.7", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, ], SWITCH_DOMAIN: [ { "entity_id": "switch.29_111111111111_pio_0", "unique_id": "/29.111111111111/PIO.0", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_1", "unique_id": "/29.111111111111/PIO.1", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_2", "unique_id": "/29.111111111111/PIO.2", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_3", "unique_id": "/29.111111111111/PIO.3", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_4", "unique_id": "/29.111111111111/PIO.4", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_5", "unique_id": "/29.111111111111/PIO.5", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_6", "unique_id": "/29.111111111111/PIO.6", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_pio_7", "unique_id": "/29.111111111111/PIO.7", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_0", "unique_id": "/29.111111111111/latch.0", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_1", "unique_id": "/29.111111111111/latch.1", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_2", "unique_id": "/29.111111111111/latch.2", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_3", "unique_id": "/29.111111111111/latch.3", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_4", "unique_id": "/29.111111111111/latch.4", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_5", "unique_id": "/29.111111111111/latch.5", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_6", "unique_id": "/29.111111111111/latch.6", "injected_value": b" 1", "result": STATE_ON, "unit": None, "class": None, "disabled": True, }, { "entity_id": "switch.29_111111111111_latch_7", "unique_id": "/29.111111111111/latch.7", "injected_value": b" 0", "result": STATE_OFF, "unit": None, "class": None, "disabled": True, }, ], }, "3B.111111111111": { "inject_reads": [ b"DS1825", # read device type ], "device_info": { "identifiers": {(DOMAIN, "3B.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS1825", "name": "3B.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.3b_111111111111_temperature", "unique_id": "/3B.111111111111/temperature", "injected_value": b" 28.243", "result": "28.2", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "42.111111111111": { "inject_reads": [ b"DS28EA00", # read device type ], "device_info": { "identifiers": {(DOMAIN, "42.111111111111")}, "manufacturer": "Maxim Integrated", "model": "DS28EA00", "name": "42.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.42_111111111111_temperature", "unique_id": "/42.111111111111/temperature", "injected_value": b" 29.123", "result": "29.1", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "EF.111111111111": { "inject_reads": [ b"HobbyBoards_EF", # read type ], "device_info": { "identifiers": {(DOMAIN, "EF.111111111111")}, "manufacturer": "Maxim Integrated", "model": "HobbyBoards_EF", "name": "EF.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.ef_111111111111_humidity", "unique_id": "/EF.111111111111/humidity/humidity_corrected", "injected_value": b" 67.745", "result": "67.7", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, }, { "entity_id": "sensor.ef_111111111111_humidity_raw", "unique_id": "/EF.111111111111/humidity/humidity_raw", "injected_value": b" 65.541", "result": "65.5", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, }, { "entity_id": "sensor.ef_111111111111_temperature", "unique_id": "/EF.111111111111/humidity/temperature", "injected_value": b" 25.123", "result": "25.1", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "EF.111111111112": { "inject_reads": [ b"HB_MOISTURE_METER", # read type b" 1", # read is_leaf_0 b" 1", # read is_leaf_1 b" 0", # read is_leaf_2 b" 0", # read is_leaf_3 ], "device_info": { "identifiers": {(DOMAIN, "EF.111111111112")}, "manufacturer": "Maxim Integrated", "model": "HB_MOISTURE_METER", "name": "EF.111111111112", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.ef_111111111112_wetness_0", "unique_id": "/EF.111111111112/moisture/sensor.0", "injected_value": b" 41.745", "result": "41.7", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, }, { "entity_id": "sensor.ef_111111111112_wetness_1", "unique_id": "/EF.111111111112/moisture/sensor.1", "injected_value": b" 42.541", "result": "42.5", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, }, { "entity_id": "sensor.ef_111111111112_moisture_2", "unique_id": "/EF.111111111112/moisture/sensor.2", "injected_value": b" 43.123", "result": "43.1", "unit": PRESSURE_CBAR, "class": DEVICE_CLASS_PRESSURE, }, { "entity_id": "sensor.ef_111111111112_moisture_3", "unique_id": "/EF.111111111112/moisture/sensor.3", "injected_value": b" 44.123", "result": "44.1", "unit": PRESSURE_CBAR, "class": DEVICE_CLASS_PRESSURE, }, ], }, "7E.111111111111": { "inject_reads": [ b"EDS", # read type b"EDS0068", # read device_type - note EDS specific ], "device_info": { "identifiers": {(DOMAIN, "7E.111111111111")}, "manufacturer": "Maxim Integrated", "model": "EDS", "name": "7E.111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.7e_111111111111_temperature", "unique_id": "/7E.111111111111/EDS0068/temperature", "injected_value": b" 13.9375", "result": "13.9", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, { "entity_id": "sensor.7e_111111111111_pressure", "unique_id": "/7E.111111111111/EDS0068/pressure", "injected_value": b" 1012.21", "result": "1012.2", "unit": PRESSURE_MBAR, "class": DEVICE_CLASS_PRESSURE, }, { "entity_id": "sensor.7e_111111111111_illuminance", "unique_id": "/7E.111111111111/EDS0068/light", "injected_value": b" 65.8839", "result": "65.9", "unit": LIGHT_LUX, "class": DEVICE_CLASS_ILLUMINANCE, }, { "entity_id": "sensor.7e_111111111111_humidity", "unique_id": "/7E.111111111111/EDS0068/humidity", "injected_value": b" 41.375", "result": "41.4", "unit": PERCENTAGE, "class": DEVICE_CLASS_HUMIDITY, }, ], }, "7E.222222222222": { "inject_reads": [ b"EDS", # read type b"EDS0066", # read device_type - note EDS specific ], "device_info": { "identifiers": {(DOMAIN, "7E.222222222222")}, "manufacturer": "Maxim Integrated", "model": "EDS", "name": "7E.222222222222", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.7e_222222222222_temperature", "unique_id": "/7E.222222222222/EDS0066/temperature", "injected_value": b" 13.9375", "result": "13.9", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, { "entity_id": "sensor.7e_222222222222_pressure", "unique_id": "/7E.222222222222/EDS0066/pressure", "injected_value": b" 1012.21", "result": "1012.2", "unit": PRESSURE_MBAR, "class": DEVICE_CLASS_PRESSURE, }, ], }, } MOCK_SYSBUS_DEVICES = { "00-111111111111": {SENSOR_DOMAIN: []}, "10-111111111111": { "device_info": { "identifiers": {(DOMAIN, "10-111111111111")}, "manufacturer": "Maxim Integrated", "model": "10", "name": "10-111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.my_ds18b20_temperature", "unique_id": "/sys/bus/w1/devices/10-111111111111/w1_slave", "injected_value": 25.123, "result": "25.1", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "12-111111111111": {SENSOR_DOMAIN: []}, "1D-111111111111": {SENSOR_DOMAIN: []}, "22-111111111111": { "device_info": { "identifiers": {(DOMAIN, "22-111111111111")}, "manufacturer": "Maxim Integrated", "model": "22", "name": "22-111111111111", }, "sensor": [ { "entity_id": "sensor.22_111111111111_temperature", "unique_id": "/sys/bus/w1/devices/22-111111111111/w1_slave", "injected_value": FileNotFoundError, "result": "unknown", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "26-111111111111": {SENSOR_DOMAIN: []}, "28-111111111111": { "device_info": { "identifiers": {(DOMAIN, "28-111111111111")}, "manufacturer": "Maxim Integrated", "model": "28", "name": "28-111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.28_111111111111_temperature", "unique_id": "/sys/bus/w1/devices/28-111111111111/w1_slave", "injected_value": InvalidCRCException, "result": "unknown", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "29-111111111111": {SENSOR_DOMAIN: []}, "3B-111111111111": { "device_info": { "identifiers": {(DOMAIN, "3B-111111111111")}, "manufacturer": "Maxim Integrated", "model": "3B", "name": "3B-111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.3b_111111111111_temperature", "unique_id": "/sys/bus/w1/devices/3B-111111111111/w1_slave", "injected_value": 29.993, "result": "30.0", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "42-111111111111": { "device_info": { "identifiers": {(DOMAIN, "42-111111111111")}, "manufacturer": "Maxim Integrated", "model": "42", "name": "42-111111111111", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.42_111111111111_temperature", "unique_id": "/sys/bus/w1/devices/42-111111111111/w1_slave", "injected_value": UnsupportResponseException, "result": "unknown", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "42-111111111112": { "device_info": { "identifiers": {(DOMAIN, "42-111111111112")}, "manufacturer": "Maxim Integrated", "model": "42", "name": "42-111111111112", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.42_111111111112_temperature", "unique_id": "/sys/bus/w1/devices/42-111111111112/w1_slave", "injected_value": [UnsupportResponseException] * 9 + [27.993], "result": "28.0", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "42-111111111113": { "device_info": { "identifiers": {(DOMAIN, "42-111111111113")}, "manufacturer": "Maxim Integrated", "model": "42", "name": "42-111111111113", }, SENSOR_DOMAIN: [ { "entity_id": "sensor.42_111111111113_temperature", "unique_id": "/sys/bus/w1/devices/42-111111111113/w1_slave", "injected_value": [UnsupportResponseException] * 10 + [27.993], "result": "unknown", "unit": TEMP_CELSIUS, "class": DEVICE_CLASS_TEMPERATURE, }, ], }, "EF-111111111111": { SENSOR_DOMAIN: [], }, "EF-111111111112": { SENSOR_DOMAIN: [], }, }