"""Voluptuous schemas for the KNX integration.""" from __future__ import annotations from abc import ABC from collections import OrderedDict from typing import Any, ClassVar, Final import voluptuous as vol from xknx import XKNX from xknx.devices.climate import SetpointShiftMode from xknx.dpt import DPTBase, DPTNumeric from xknx.exceptions import ConversionError, CouldNotParseAddress from xknx.io import DEFAULT_MCAST_GRP, DEFAULT_MCAST_PORT from xknx.telegram.address import IndividualAddress, parse_device_group_address from homeassistant.components.binary_sensor import ( DEVICE_CLASSES as BINARY_SENSOR_DEVICE_CLASSES, ) from homeassistant.components.climate.const import HVAC_MODE_HEAT, HVAC_MODES from homeassistant.components.cover import DEVICE_CLASSES as COVER_DEVICE_CLASSES from homeassistant.components.number import NumberMode from homeassistant.components.sensor import CONF_STATE_CLASS, STATE_CLASSES_SCHEMA from homeassistant.const import ( CONF_DEVICE_CLASS, CONF_ENTITY_CATEGORY, CONF_ENTITY_ID, CONF_EVENT, CONF_HOST, CONF_MODE, CONF_NAME, CONF_PORT, CONF_TYPE, Platform, ) import homeassistant.helpers.config_validation as cv from homeassistant.helpers.entity import ENTITY_CATEGORIES_SCHEMA from .const import ( CONF_INVERT, CONF_KNX_EXPOSE, CONF_KNX_INDIVIDUAL_ADDRESS, CONF_KNX_ROUTING, CONF_KNX_TUNNELING, CONF_PAYLOAD, CONF_PAYLOAD_LENGTH, CONF_RESET_AFTER, CONF_RESPOND_TO_READ, CONF_STATE_ADDRESS, CONF_SYNC_STATE, CONTROLLER_MODES, KNX_ADDRESS, PRESET_MODES, ColorTempModes, ) ################## # KNX VALIDATORS ################## def ga_validator(value: Any) -> str | int: """Validate that value is parsable as GroupAddress or InternalGroupAddress.""" if isinstance(value, (str, int)): try: parse_device_group_address(value) return value except CouldNotParseAddress: pass raise vol.Invalid( f"value '{value}' is not a valid KNX group address '
//', '
/' " "or '' (eg.'1/2/3', '9/234', '123'), nor xknx internal address 'i-'." ) ga_list_validator = vol.All(cv.ensure_list, [ga_validator]) ia_validator = vol.Any( cv.matches_regex(IndividualAddress.ADDRESS_RE.pattern), vol.All(vol.Coerce(int), vol.Range(min=1, max=65535)), msg="value does not match pattern for KNX individual address '..' (eg.'1.1.100')", ) def number_limit_sub_validator(entity_config: OrderedDict) -> OrderedDict: """Validate a number entity configurations dependent on configured value type.""" value_type = entity_config[CONF_TYPE] min_config: float | None = entity_config.get(NumberSchema.CONF_MIN) max_config: float | None = entity_config.get(NumberSchema.CONF_MAX) step_config: float | None = entity_config.get(NumberSchema.CONF_STEP) dpt_class = DPTNumeric.parse_transcoder(value_type) if dpt_class is None: raise vol.Invalid(f"'type: {value_type}' is not a valid numeric sensor type.") # Inifinity is not supported by Home Assistant frontend so user defined # config is required if if xknx DPTNumeric subclass defines it as limit. if min_config is None and dpt_class.value_min == float("-inf"): raise vol.Invalid(f"'min' key required for value type '{value_type}'") if min_config is not None and min_config < dpt_class.value_min: raise vol.Invalid( f"'min: {min_config}' undercuts possible minimum" f" of value type '{value_type}': {dpt_class.value_min}" ) if max_config is None and dpt_class.value_max == float("inf"): raise vol.Invalid(f"'max' key required for value type '{value_type}'") if max_config is not None and max_config > dpt_class.value_max: raise vol.Invalid( f"'max: {max_config}' exceeds possible maximum" f" of value type '{value_type}': {dpt_class.value_max}" ) if step_config is not None and step_config < dpt_class.resolution: raise vol.Invalid( f"'step: {step_config}' undercuts possible minimum step" f" of value type '{value_type}': {dpt_class.resolution}" ) return entity_config def numeric_type_validator(value: Any) -> str | int: """Validate that value is parsable as numeric sensor type.""" if isinstance(value, (str, int)) and DPTNumeric.parse_transcoder(value) is not None: return value raise vol.Invalid(f"value '{value}' is not a valid numeric sensor type.") def _max_payload_value(payload_length: int) -> int: if payload_length == 0: return 0x3F return int(256 ** payload_length) - 1 def button_payload_sub_validator(entity_config: OrderedDict) -> OrderedDict: """Validate a button entity payload configuration.""" if _type := entity_config.get(CONF_TYPE): _payload = entity_config[ButtonSchema.CONF_VALUE] if (transcoder := DPTBase.parse_transcoder(_type)) is None: raise vol.Invalid(f"'type: {_type}' is not a valid sensor type.") entity_config[CONF_PAYLOAD_LENGTH] = transcoder.payload_length try: entity_config[CONF_PAYLOAD] = int.from_bytes( transcoder.to_knx(_payload), byteorder="big" ) except ConversionError as ex: raise vol.Invalid( f"'payload: {_payload}' not valid for 'type: {_type}'" ) from ex return entity_config _payload = entity_config[CONF_PAYLOAD] _payload_length = entity_config[CONF_PAYLOAD_LENGTH] if _payload > (max_payload := _max_payload_value(_payload_length)): raise vol.Invalid( f"'payload: {_payload}' exceeds possible maximum for " f"payload_length {_payload_length}: {max_payload}" ) return entity_config def select_options_sub_validator(entity_config: OrderedDict) -> OrderedDict: """Validate a select entity options configuration.""" options_seen = set() payloads_seen = set() payload_length = entity_config[CONF_PAYLOAD_LENGTH] for opt in entity_config[SelectSchema.CONF_OPTIONS]: option = opt[SelectSchema.CONF_OPTION] payload = opt[CONF_PAYLOAD] if payload > (max_payload := _max_payload_value(payload_length)): raise vol.Invalid( f"'payload: {payload}' for 'option: {option}' exceeds possible" f" maximum of 'payload_length: {payload_length}': {max_payload}" ) if option in options_seen: raise vol.Invalid(f"duplicate item for 'option' not allowed: {option}") options_seen.add(option) if payload in payloads_seen: raise vol.Invalid(f"duplicate item for 'payload' not allowed: {payload}") payloads_seen.add(payload) return entity_config def sensor_type_validator(value: Any) -> str | int: """Validate that value is parsable as sensor type.""" if isinstance(value, (str, int)) and DPTBase.parse_transcoder(value) is not None: return value raise vol.Invalid(f"value '{value}' is not a valid sensor type.") sync_state_validator = vol.Any( vol.All(vol.Coerce(int), vol.Range(min=2, max=1440)), cv.boolean, cv.matches_regex(r"^(init|expire|every)( \d*)?$"), ) ############## # CONNECTION ############## class ConnectionSchema: """ Voluptuous schema for KNX connection. DEPRECATED: Migrated to config and options flow. Will be removed in a future version of Home Assistant. """ CONF_KNX_LOCAL_IP = "local_ip" CONF_KNX_MCAST_GRP = "multicast_group" CONF_KNX_MCAST_PORT = "multicast_port" CONF_KNX_RATE_LIMIT = "rate_limit" CONF_KNX_ROUTE_BACK = "route_back" CONF_KNX_STATE_UPDATER = "state_updater" CONF_KNX_DEFAULT_STATE_UPDATER = True CONF_KNX_DEFAULT_RATE_LIMIT = 20 TUNNELING_SCHEMA = vol.Schema( { vol.Optional(CONF_PORT, default=DEFAULT_MCAST_PORT): cv.port, vol.Required(CONF_HOST): cv.string, vol.Optional(CONF_KNX_LOCAL_IP): cv.string, vol.Optional(CONF_KNX_ROUTE_BACK, default=False): cv.boolean, } ) ROUTING_SCHEMA = vol.Maybe(vol.Schema({vol.Optional(CONF_KNX_LOCAL_IP): cv.string})) SCHEMA = { vol.Exclusive(CONF_KNX_ROUTING, "connection_type"): ROUTING_SCHEMA, vol.Exclusive(CONF_KNX_TUNNELING, "connection_type"): TUNNELING_SCHEMA, vol.Optional( CONF_KNX_INDIVIDUAL_ADDRESS, default=XKNX.DEFAULT_ADDRESS ): ia_validator, vol.Optional(CONF_KNX_MCAST_GRP, default=DEFAULT_MCAST_GRP): cv.string, vol.Optional(CONF_KNX_MCAST_PORT, default=DEFAULT_MCAST_PORT): cv.port, vol.Optional( CONF_KNX_STATE_UPDATER, default=CONF_KNX_DEFAULT_STATE_UPDATER ): cv.boolean, vol.Optional(CONF_KNX_RATE_LIMIT, default=CONF_KNX_DEFAULT_RATE_LIMIT): vol.All( vol.Coerce(int), vol.Range(min=1, max=100) ), } ######### # EVENT ######### class EventSchema: """Voluptuous schema for KNX events.""" KNX_EVENT_FILTER_SCHEMA = vol.Schema( { vol.Required(KNX_ADDRESS): vol.All(cv.ensure_list, [cv.string]), vol.Optional(CONF_TYPE): sensor_type_validator, } ) SCHEMA = { vol.Optional(CONF_EVENT, default=[]): vol.All( cv.ensure_list, [KNX_EVENT_FILTER_SCHEMA] ) } ############# # PLATFORMS ############# class KNXPlatformSchema(ABC): """Voluptuous schema for KNX platform entity configuration.""" PLATFORM: ClassVar[Platform | str] ENTITY_SCHEMA: ClassVar[vol.Schema] @classmethod def platform_node(cls) -> dict[vol.Optional, vol.All]: """Return a schema node for the platform.""" return { vol.Optional(str(cls.PLATFORM)): vol.All( cv.ensure_list, [cls.ENTITY_SCHEMA] ) } class BinarySensorSchema(KNXPlatformSchema): """Voluptuous schema for KNX binary sensors.""" PLATFORM = Platform.BINARY_SENSOR CONF_STATE_ADDRESS = CONF_STATE_ADDRESS CONF_SYNC_STATE = CONF_SYNC_STATE CONF_INVERT = CONF_INVERT CONF_IGNORE_INTERNAL_STATE = "ignore_internal_state" CONF_CONTEXT_TIMEOUT = "context_timeout" CONF_RESET_AFTER = CONF_RESET_AFTER DEFAULT_NAME = "KNX Binary Sensor" ENTITY_SCHEMA = vol.All( # deprecated since September 2020 cv.deprecated("significant_bit"), cv.deprecated("automation"), vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator, vol.Optional(CONF_IGNORE_INTERNAL_STATE, default=False): cv.boolean, vol.Optional(CONF_INVERT, default=False): cv.boolean, vol.Required(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_CONTEXT_TIMEOUT): vol.All( vol.Coerce(float), vol.Range(min=0, max=10) ), vol.Optional(CONF_DEVICE_CLASS): vol.In(BINARY_SENSOR_DEVICE_CLASSES), vol.Optional(CONF_RESET_AFTER): cv.positive_float, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), ) class ButtonSchema(KNXPlatformSchema): """Voluptuous schema for KNX buttons.""" PLATFORM = Platform.BUTTON CONF_VALUE = "value" DEFAULT_NAME = "KNX Button" payload_or_value_msg = f"Please use only one of `{CONF_PAYLOAD}` or `{CONF_VALUE}`" length_or_type_msg = ( f"Please use only one of `{CONF_PAYLOAD_LENGTH}` or `{CONF_TYPE}`" ) ENTITY_SCHEMA = vol.All( vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Required(KNX_ADDRESS): ga_validator, vol.Exclusive( CONF_PAYLOAD, "payload_or_value", msg=payload_or_value_msg ): object, vol.Exclusive( CONF_VALUE, "payload_or_value", msg=payload_or_value_msg ): object, vol.Exclusive( CONF_PAYLOAD_LENGTH, "length_or_type", msg=length_or_type_msg ): object, vol.Exclusive( CONF_TYPE, "length_or_type", msg=length_or_type_msg ): object, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), vol.Any( vol.Schema( # encoded value { vol.Required(CONF_VALUE): vol.Any(int, float, str), vol.Required(CONF_TYPE): sensor_type_validator, }, extra=vol.ALLOW_EXTRA, ), vol.Schema( # raw payload - default is DPT 1 style True { vol.Optional(CONF_PAYLOAD, default=1): cv.positive_int, vol.Optional(CONF_PAYLOAD_LENGTH, default=0): vol.All( vol.Coerce(int), vol.Range(min=0, max=14) ), vol.Optional(CONF_VALUE): None, vol.Optional(CONF_TYPE): None, }, extra=vol.ALLOW_EXTRA, ), ), # calculate raw CONF_PAYLOAD and CONF_PAYLOAD_LENGTH # from CONF_VALUE and CONF_TYPE if given and check payload size button_payload_sub_validator, ) class ClimateSchema(KNXPlatformSchema): """Voluptuous schema for KNX climate devices.""" PLATFORM = Platform.CLIMATE CONF_ACTIVE_STATE_ADDRESS = "active_state_address" CONF_SETPOINT_SHIFT_ADDRESS = "setpoint_shift_address" CONF_SETPOINT_SHIFT_STATE_ADDRESS = "setpoint_shift_state_address" CONF_SETPOINT_SHIFT_MODE = "setpoint_shift_mode" CONF_SETPOINT_SHIFT_MAX = "setpoint_shift_max" CONF_SETPOINT_SHIFT_MIN = "setpoint_shift_min" CONF_TEMPERATURE_ADDRESS = "temperature_address" CONF_TEMPERATURE_STEP = "temperature_step" CONF_TARGET_TEMPERATURE_ADDRESS = "target_temperature_address" CONF_TARGET_TEMPERATURE_STATE_ADDRESS = "target_temperature_state_address" CONF_OPERATION_MODE_ADDRESS = "operation_mode_address" CONF_OPERATION_MODE_STATE_ADDRESS = "operation_mode_state_address" CONF_CONTROLLER_STATUS_ADDRESS = "controller_status_address" CONF_CONTROLLER_STATUS_STATE_ADDRESS = "controller_status_state_address" CONF_CONTROLLER_MODE_ADDRESS = "controller_mode_address" CONF_CONTROLLER_MODE_STATE_ADDRESS = "controller_mode_state_address" CONF_COMMAND_VALUE_STATE_ADDRESS = "command_value_state_address" CONF_HEAT_COOL_ADDRESS = "heat_cool_address" CONF_HEAT_COOL_STATE_ADDRESS = "heat_cool_state_address" CONF_OPERATION_MODE_FROST_PROTECTION_ADDRESS = ( "operation_mode_frost_protection_address" ) CONF_OPERATION_MODE_NIGHT_ADDRESS = "operation_mode_night_address" CONF_OPERATION_MODE_COMFORT_ADDRESS = "operation_mode_comfort_address" CONF_OPERATION_MODE_STANDBY_ADDRESS = "operation_mode_standby_address" CONF_OPERATION_MODES = "operation_modes" CONF_CONTROLLER_MODES = "controller_modes" CONF_DEFAULT_CONTROLLER_MODE = "default_controller_mode" CONF_ON_OFF_ADDRESS = "on_off_address" CONF_ON_OFF_STATE_ADDRESS = "on_off_state_address" CONF_ON_OFF_INVERT = "on_off_invert" CONF_MIN_TEMP = "min_temp" CONF_MAX_TEMP = "max_temp" DEFAULT_NAME = "KNX Climate" DEFAULT_SETPOINT_SHIFT_MODE = "DPT6010" DEFAULT_SETPOINT_SHIFT_MAX = 6 DEFAULT_SETPOINT_SHIFT_MIN = -6 DEFAULT_TEMPERATURE_STEP = 0.1 DEFAULT_ON_OFF_INVERT = False ENTITY_SCHEMA = vol.All( # deprecated since September 2020 cv.deprecated("setpoint_shift_step", replacement_key=CONF_TEMPERATURE_STEP), # deprecated since 2021.6 cv.deprecated("create_temperature_sensors"), vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional( CONF_SETPOINT_SHIFT_MAX, default=DEFAULT_SETPOINT_SHIFT_MAX ): vol.All(int, vol.Range(min=0, max=32)), vol.Optional( CONF_SETPOINT_SHIFT_MIN, default=DEFAULT_SETPOINT_SHIFT_MIN ): vol.All(int, vol.Range(min=-32, max=0)), vol.Optional( CONF_TEMPERATURE_STEP, default=DEFAULT_TEMPERATURE_STEP ): vol.All(float, vol.Range(min=0, max=2)), vol.Required(CONF_TEMPERATURE_ADDRESS): ga_list_validator, vol.Required(CONF_TARGET_TEMPERATURE_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_TARGET_TEMPERATURE_ADDRESS): ga_list_validator, vol.Inclusive( CONF_SETPOINT_SHIFT_ADDRESS, "setpoint_shift", msg="'setpoint_shift_address' and 'setpoint_shift_state_address' " "are required for setpoint_shift configuration", ): ga_list_validator, vol.Inclusive( CONF_SETPOINT_SHIFT_STATE_ADDRESS, "setpoint_shift", msg="'setpoint_shift_address' and 'setpoint_shift_state_address' " "are required for setpoint_shift configuration", ): ga_list_validator, vol.Optional(CONF_SETPOINT_SHIFT_MODE): vol.Maybe( vol.All(vol.Upper, cv.enum(SetpointShiftMode)) ), vol.Optional(CONF_ACTIVE_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_COMMAND_VALUE_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_OPERATION_MODE_ADDRESS): ga_list_validator, vol.Optional(CONF_OPERATION_MODE_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_CONTROLLER_STATUS_ADDRESS): ga_list_validator, vol.Optional(CONF_CONTROLLER_STATUS_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_CONTROLLER_MODE_ADDRESS): ga_list_validator, vol.Optional(CONF_CONTROLLER_MODE_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_HEAT_COOL_ADDRESS): ga_list_validator, vol.Optional(CONF_HEAT_COOL_STATE_ADDRESS): ga_list_validator, vol.Optional( CONF_OPERATION_MODE_FROST_PROTECTION_ADDRESS ): ga_list_validator, vol.Optional(CONF_OPERATION_MODE_NIGHT_ADDRESS): ga_list_validator, vol.Optional(CONF_OPERATION_MODE_COMFORT_ADDRESS): ga_list_validator, vol.Optional(CONF_OPERATION_MODE_STANDBY_ADDRESS): ga_list_validator, vol.Optional(CONF_ON_OFF_ADDRESS): ga_list_validator, vol.Optional(CONF_ON_OFF_STATE_ADDRESS): ga_list_validator, vol.Optional( CONF_ON_OFF_INVERT, default=DEFAULT_ON_OFF_INVERT ): cv.boolean, vol.Optional(CONF_OPERATION_MODES): vol.All( cv.ensure_list, [vol.In(PRESET_MODES)] ), vol.Optional(CONF_CONTROLLER_MODES): vol.All( cv.ensure_list, [vol.In(CONTROLLER_MODES)] ), vol.Optional( CONF_DEFAULT_CONTROLLER_MODE, default=HVAC_MODE_HEAT ): vol.In(HVAC_MODES), vol.Optional(CONF_MIN_TEMP): vol.Coerce(float), vol.Optional(CONF_MAX_TEMP): vol.Coerce(float), vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), ) class CoverSchema(KNXPlatformSchema): """Voluptuous schema for KNX covers.""" PLATFORM = Platform.COVER CONF_MOVE_LONG_ADDRESS = "move_long_address" CONF_MOVE_SHORT_ADDRESS = "move_short_address" CONF_STOP_ADDRESS = "stop_address" CONF_POSITION_ADDRESS = "position_address" CONF_POSITION_STATE_ADDRESS = "position_state_address" CONF_ANGLE_ADDRESS = "angle_address" CONF_ANGLE_STATE_ADDRESS = "angle_state_address" CONF_TRAVELLING_TIME_DOWN = "travelling_time_down" CONF_TRAVELLING_TIME_UP = "travelling_time_up" CONF_INVERT_POSITION = "invert_position" CONF_INVERT_ANGLE = "invert_angle" DEFAULT_TRAVEL_TIME = 25 DEFAULT_NAME = "KNX Cover" ENTITY_SCHEMA = vol.All( vol.Schema( { vol.Required( vol.Any(CONF_MOVE_LONG_ADDRESS, CONF_POSITION_ADDRESS), msg=f"At least one of '{CONF_MOVE_LONG_ADDRESS}' or '{CONF_POSITION_ADDRESS}' is required.", ): object, }, extra=vol.ALLOW_EXTRA, ), vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_MOVE_LONG_ADDRESS): ga_list_validator, vol.Optional(CONF_MOVE_SHORT_ADDRESS): ga_list_validator, vol.Optional(CONF_STOP_ADDRESS): ga_list_validator, vol.Optional(CONF_POSITION_ADDRESS): ga_list_validator, vol.Optional(CONF_POSITION_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_ANGLE_ADDRESS): ga_list_validator, vol.Optional(CONF_ANGLE_STATE_ADDRESS): ga_list_validator, vol.Optional( CONF_TRAVELLING_TIME_DOWN, default=DEFAULT_TRAVEL_TIME ): cv.positive_float, vol.Optional( CONF_TRAVELLING_TIME_UP, default=DEFAULT_TRAVEL_TIME ): cv.positive_float, vol.Optional(CONF_INVERT_POSITION, default=False): cv.boolean, vol.Optional(CONF_INVERT_ANGLE, default=False): cv.boolean, vol.Optional(CONF_DEVICE_CLASS): vol.In(COVER_DEVICE_CLASSES), vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), ) class ExposeSchema(KNXPlatformSchema): """Voluptuous schema for KNX exposures.""" PLATFORM = CONF_KNX_EXPOSE CONF_KNX_EXPOSE_TYPE = CONF_TYPE CONF_KNX_EXPOSE_ATTRIBUTE = "attribute" CONF_KNX_EXPOSE_BINARY = "binary" CONF_KNX_EXPOSE_DEFAULT = "default" EXPOSE_TIME_TYPES: Final = [ "time", "date", "datetime", ] EXPOSE_TIME_SCHEMA = vol.Schema( { vol.Required(CONF_KNX_EXPOSE_TYPE): vol.All( cv.string, str.lower, vol.In(EXPOSE_TIME_TYPES) ), vol.Required(KNX_ADDRESS): ga_validator, } ) EXPOSE_SENSOR_SCHEMA = vol.Schema( { vol.Required(CONF_KNX_EXPOSE_TYPE): vol.Any( CONF_KNX_EXPOSE_BINARY, sensor_type_validator ), vol.Required(KNX_ADDRESS): ga_validator, vol.Required(CONF_ENTITY_ID): cv.entity_id, vol.Optional(CONF_KNX_EXPOSE_ATTRIBUTE): cv.string, vol.Optional(CONF_KNX_EXPOSE_DEFAULT): cv.match_all, } ) ENTITY_SCHEMA = vol.Any(EXPOSE_SENSOR_SCHEMA, EXPOSE_TIME_SCHEMA) class FanSchema(KNXPlatformSchema): """Voluptuous schema for KNX fans.""" PLATFORM = Platform.FAN CONF_STATE_ADDRESS = CONF_STATE_ADDRESS CONF_OSCILLATION_ADDRESS = "oscillation_address" CONF_OSCILLATION_STATE_ADDRESS = "oscillation_state_address" CONF_MAX_STEP = "max_step" DEFAULT_NAME = "KNX Fan" ENTITY_SCHEMA = vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Required(KNX_ADDRESS): ga_list_validator, vol.Optional(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_OSCILLATION_ADDRESS): ga_list_validator, vol.Optional(CONF_OSCILLATION_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_MAX_STEP): cv.byte, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ) class LightSchema(KNXPlatformSchema): """Voluptuous schema for KNX lights.""" PLATFORM = Platform.LIGHT CONF_STATE_ADDRESS = CONF_STATE_ADDRESS CONF_BRIGHTNESS_ADDRESS = "brightness_address" CONF_BRIGHTNESS_STATE_ADDRESS = "brightness_state_address" CONF_COLOR_ADDRESS = "color_address" CONF_COLOR_STATE_ADDRESS = "color_state_address" CONF_COLOR_TEMP_ADDRESS = "color_temperature_address" CONF_COLOR_TEMP_STATE_ADDRESS = "color_temperature_state_address" CONF_COLOR_TEMP_MODE = "color_temperature_mode" CONF_HUE_ADDRESS = "hue_address" CONF_HUE_STATE_ADDRESS = "hue_state_address" CONF_RGBW_ADDRESS = "rgbw_address" CONF_RGBW_STATE_ADDRESS = "rgbw_state_address" CONF_SATURATION_ADDRESS = "saturation_address" CONF_SATURATION_STATE_ADDRESS = "saturation_state_address" CONF_XYY_ADDRESS = "xyy_address" CONF_XYY_STATE_ADDRESS = "xyy_state_address" CONF_MIN_KELVIN = "min_kelvin" CONF_MAX_KELVIN = "max_kelvin" DEFAULT_NAME = "KNX Light" DEFAULT_COLOR_TEMP_MODE = "absolute" DEFAULT_MIN_KELVIN = 2700 # 370 mireds DEFAULT_MAX_KELVIN = 6000 # 166 mireds CONF_INDIVIDUAL_COLORS = "individual_colors" CONF_RED = "red" CONF_GREEN = "green" CONF_BLUE = "blue" CONF_WHITE = "white" _hs_color_inclusion_msg = ( "'hue_address', 'saturation_address' and 'brightness_address'" " are required for hs_color configuration" ) HS_COLOR_SCHEMA = { vol.Optional(CONF_HUE_ADDRESS): ga_list_validator, vol.Optional(CONF_HUE_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_SATURATION_ADDRESS): ga_list_validator, vol.Optional(CONF_SATURATION_STATE_ADDRESS): ga_list_validator, } INDIVIDUAL_COLOR_SCHEMA = vol.Schema( { vol.Optional(KNX_ADDRESS): ga_list_validator, vol.Optional(CONF_STATE_ADDRESS): ga_list_validator, vol.Required(CONF_BRIGHTNESS_ADDRESS): ga_list_validator, vol.Optional(CONF_BRIGHTNESS_STATE_ADDRESS): ga_list_validator, } ) ENTITY_SCHEMA = vol.All( vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(KNX_ADDRESS): ga_list_validator, vol.Optional(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_BRIGHTNESS_ADDRESS): ga_list_validator, vol.Optional(CONF_BRIGHTNESS_STATE_ADDRESS): ga_list_validator, vol.Exclusive(CONF_INDIVIDUAL_COLORS, "color"): { vol.Inclusive( CONF_RED, "individual_colors", msg="'red', 'green' and 'blue' are required for individual colors configuration", ): INDIVIDUAL_COLOR_SCHEMA, vol.Inclusive( CONF_GREEN, "individual_colors", msg="'red', 'green' and 'blue' are required for individual colors configuration", ): INDIVIDUAL_COLOR_SCHEMA, vol.Inclusive( CONF_BLUE, "individual_colors", msg="'red', 'green' and 'blue' are required for individual colors configuration", ): INDIVIDUAL_COLOR_SCHEMA, vol.Optional(CONF_WHITE): INDIVIDUAL_COLOR_SCHEMA, }, vol.Exclusive(CONF_COLOR_ADDRESS, "color"): ga_list_validator, vol.Optional(CONF_COLOR_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_COLOR_TEMP_ADDRESS): ga_list_validator, vol.Optional(CONF_COLOR_TEMP_STATE_ADDRESS): ga_list_validator, vol.Optional( CONF_COLOR_TEMP_MODE, default=DEFAULT_COLOR_TEMP_MODE ): vol.All(vol.Upper, cv.enum(ColorTempModes)), **HS_COLOR_SCHEMA, vol.Exclusive(CONF_RGBW_ADDRESS, "color"): ga_list_validator, vol.Optional(CONF_RGBW_STATE_ADDRESS): ga_list_validator, vol.Exclusive(CONF_XYY_ADDRESS, "color"): ga_list_validator, vol.Optional(CONF_XYY_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_MIN_KELVIN, default=DEFAULT_MIN_KELVIN): vol.All( vol.Coerce(int), vol.Range(min=1) ), vol.Optional(CONF_MAX_KELVIN, default=DEFAULT_MAX_KELVIN): vol.All( vol.Coerce(int), vol.Range(min=1) ), vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), vol.Any( vol.Schema( {vol.Required(KNX_ADDRESS): object}, extra=vol.ALLOW_EXTRA, ), vol.Schema( # brightness addresses are required in INDIVIDUAL_COLOR_SCHEMA {vol.Required(CONF_INDIVIDUAL_COLORS): object}, extra=vol.ALLOW_EXTRA, ), msg="either 'address' or 'individual_colors' is required", ), vol.Any( vol.Schema( # 'brightness' is non-optional for hs-color { vol.Inclusive( CONF_BRIGHTNESS_ADDRESS, "hs_color", msg=_hs_color_inclusion_msg ): object, vol.Inclusive( CONF_HUE_ADDRESS, "hs_color", msg=_hs_color_inclusion_msg ): object, vol.Inclusive( CONF_SATURATION_ADDRESS, "hs_color", msg=_hs_color_inclusion_msg ): object, }, extra=vol.ALLOW_EXTRA, ), vol.Schema( # hs-colors not used { vol.Optional(CONF_HUE_ADDRESS): None, vol.Optional(CONF_SATURATION_ADDRESS): None, }, extra=vol.ALLOW_EXTRA, ), msg=_hs_color_inclusion_msg, ), ) class NotifySchema(KNXPlatformSchema): """Voluptuous schema for KNX notifications.""" PLATFORM = Platform.NOTIFY DEFAULT_NAME = "KNX Notify" ENTITY_SCHEMA = vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Required(KNX_ADDRESS): ga_validator, } ) class NumberSchema(KNXPlatformSchema): """Voluptuous schema for KNX numbers.""" PLATFORM = Platform.NUMBER CONF_MAX = "max" CONF_MIN = "min" CONF_STEP = "step" DEFAULT_NAME = "KNX Number" ENTITY_SCHEMA = vol.All( vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_RESPOND_TO_READ, default=False): cv.boolean, vol.Optional(CONF_MODE, default=NumberMode.AUTO): vol.Coerce( NumberMode ), vol.Required(CONF_TYPE): numeric_type_validator, vol.Required(KNX_ADDRESS): ga_list_validator, vol.Optional(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_MAX): vol.Coerce(float), vol.Optional(CONF_MIN): vol.Coerce(float), vol.Optional(CONF_STEP): cv.positive_float, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), number_limit_sub_validator, ) class SceneSchema(KNXPlatformSchema): """Voluptuous schema for KNX scenes.""" PLATFORM = Platform.SCENE CONF_SCENE_NUMBER = "scene_number" DEFAULT_NAME = "KNX SCENE" ENTITY_SCHEMA = vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Required(KNX_ADDRESS): ga_list_validator, vol.Required(CONF_SCENE_NUMBER): vol.All( vol.Coerce(int), vol.Range(min=1, max=64) ), vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ) class SelectSchema(KNXPlatformSchema): """Voluptuous schema for KNX selects.""" PLATFORM = Platform.SELECT CONF_OPTION = "option" CONF_OPTIONS = "options" DEFAULT_NAME = "KNX Select" ENTITY_SCHEMA = vol.All( vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator, vol.Optional(CONF_RESPOND_TO_READ, default=False): cv.boolean, vol.Required(CONF_PAYLOAD_LENGTH): vol.All( vol.Coerce(int), vol.Range(min=0, max=14) ), vol.Required(CONF_OPTIONS): [ { vol.Required(CONF_OPTION): vol.Coerce(str), vol.Required(CONF_PAYLOAD): cv.positive_int, } ], vol.Required(KNX_ADDRESS): ga_list_validator, vol.Optional(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), select_options_sub_validator, ) class SensorSchema(KNXPlatformSchema): """Voluptuous schema for KNX sensors.""" PLATFORM = Platform.SENSOR CONF_ALWAYS_CALLBACK = "always_callback" CONF_STATE_ADDRESS = CONF_STATE_ADDRESS CONF_SYNC_STATE = CONF_SYNC_STATE DEFAULT_NAME = "KNX Sensor" ENTITY_SCHEMA = vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator, vol.Optional(CONF_ALWAYS_CALLBACK, default=False): cv.boolean, vol.Optional(CONF_STATE_CLASS): STATE_CLASSES_SCHEMA, vol.Required(CONF_TYPE): sensor_type_validator, vol.Required(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ) class SwitchSchema(KNXPlatformSchema): """Voluptuous schema for KNX switches.""" PLATFORM = Platform.SWITCH CONF_INVERT = CONF_INVERT CONF_STATE_ADDRESS = CONF_STATE_ADDRESS DEFAULT_NAME = "KNX Switch" ENTITY_SCHEMA = vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_INVERT, default=False): cv.boolean, vol.Optional(CONF_RESPOND_TO_READ, default=False): cv.boolean, vol.Required(KNX_ADDRESS): ga_list_validator, vol.Optional(CONF_STATE_ADDRESS): ga_list_validator, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ) class WeatherSchema(KNXPlatformSchema): """Voluptuous schema for KNX weather station.""" PLATFORM = Platform.WEATHER CONF_SYNC_STATE = CONF_SYNC_STATE CONF_KNX_TEMPERATURE_ADDRESS = "address_temperature" CONF_KNX_BRIGHTNESS_SOUTH_ADDRESS = "address_brightness_south" CONF_KNX_BRIGHTNESS_EAST_ADDRESS = "address_brightness_east" CONF_KNX_BRIGHTNESS_WEST_ADDRESS = "address_brightness_west" CONF_KNX_BRIGHTNESS_NORTH_ADDRESS = "address_brightness_north" CONF_KNX_WIND_SPEED_ADDRESS = "address_wind_speed" CONF_KNX_WIND_BEARING_ADDRESS = "address_wind_bearing" CONF_KNX_RAIN_ALARM_ADDRESS = "address_rain_alarm" CONF_KNX_FROST_ALARM_ADDRESS = "address_frost_alarm" CONF_KNX_WIND_ALARM_ADDRESS = "address_wind_alarm" CONF_KNX_DAY_NIGHT_ADDRESS = "address_day_night" CONF_KNX_AIR_PRESSURE_ADDRESS = "address_air_pressure" CONF_KNX_HUMIDITY_ADDRESS = "address_humidity" DEFAULT_NAME = "KNX Weather Station" ENTITY_SCHEMA = vol.All( # deprecated since 2021.6 cv.deprecated("create_sensors"), vol.Schema( { vol.Optional(CONF_NAME, default=DEFAULT_NAME): cv.string, vol.Optional(CONF_SYNC_STATE, default=True): sync_state_validator, vol.Required(CONF_KNX_TEMPERATURE_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_BRIGHTNESS_SOUTH_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_BRIGHTNESS_EAST_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_BRIGHTNESS_WEST_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_BRIGHTNESS_NORTH_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_WIND_SPEED_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_WIND_BEARING_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_RAIN_ALARM_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_FROST_ALARM_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_WIND_ALARM_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_DAY_NIGHT_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_AIR_PRESSURE_ADDRESS): ga_list_validator, vol.Optional(CONF_KNX_HUMIDITY_ADDRESS): ga_list_validator, vol.Optional(CONF_ENTITY_CATEGORY): ENTITY_CATEGORIES_SCHEMA, } ), )