* Add tests to reach full coverage for helpers/state.py.
* Refactor reproduce_state function in helpers/state.py. Add two dicts,
as global constants, service_attributes and service_to_state. Use
these in combination with the dict of services per domain from
ServiceRegistry, to find the correct service to use in a scene state
change.
* Use break statement in for loop, to break if service was selected
to update state, in preference to update state attributes, ie state
update takes precedence.
* Add ATTR_CODE and ATTR_CODE_FORMAT in const. Import these in
alarm_control_panel and lock platforms instead of making duplicate
constants in multiple modules.
* Use ATTR_MEDIA_CONTENT_TYPE and ATTR_MEDIA_CONTENT_ID in media_player
platform in SERVICE_PLAY_MEDIA and play_media methods, instead of
'media_type' and 'media_id'.
* Fix PEP257 in modified files.
The default configuration of the mFi controller generates self-signed
certificates which are valid for short periods of time, and which are
regnerated on start or as needed. This makes requests mad. Since most
people will be using the self-signed certificates anyway, add options
to let them choose non-TLS, or unverified connections if they want/need.
This bumps the mficlient requirement to 0.3.0 for proper handling of
verify=False.
Converts 0..255 values that HA expects into a device 0..SCALE value
Example:
HA considers "hall light" at 25 brightness or 10% of 255
Device considers "hall light" at 100 brightness or 10% of 1000
This allows our existing MQTT devices to not change their data format to be used in HA
The exception we were catching incorrectly referenced the client variable
in local scope instead of the module. Also, if we fail to connect we can
get a requests exception, so catch and handle that as well.
The older (unsupported AirCam) models behave differently and also apparently
suffer some under the last release of the NVR that supported them. Since they
are EOL and not supported by current software, filter them out so we don't
break while trying to extract an image from them.
This adds tests for the uvc camera module. It's a good thing too,
because I found a few bugs which are fixed here as well:
- Graceful handling of non-integer port
- Failure to take the first host that works when probing host,internalHost
- Failure to detect if neither of them actually work
This also converts the code to only call add_devices once with a listcomp.
* Add mysensors binary sensor.
* Add discovery platforms to binary_sensor base component.
* Replace device_state_attributes with state_attributes in
binary_sensor base class.
* Fix docstrings.
* Add discovery of binary sensor to mysensors component.
* Add child.type as argument to mysensors device_class.
* Move binary sensor types from sensor to binary_sensor module.
* Fix binary_sensor attribute tests. Use state_attributes instead of
device_state_attributes.
Ubiquiti's Unifi WAP infrastructure has a central controller (like mfi and uvc)
that can be queried for client status. This adds a device_tracker module that
can report the state of any client connected to the controller.
This adds a 'sensor_class' property and attribute, which should be either
None or one of several defined SENSOR_CLASSES to indicate contextual
information about what the sensor is measuring.
* Make a flatter one level inheritance, with MySensorsLight as parent
with four children, one per light type.
* Break out helper methods. One per plain light, dimmer and RGB/RGBW
children and per update, turn_on and turn_off, nine in total. Put
these in the parent.
* Call the helper methods as needed from the child methods update,
turn_on and turn_off.
* Change name of MySensorsLightLight to MySensorsLightPlain.
* Fix module docstrings according to pep257.
* Change name of color util method from rgb_hex_to_list to
rgb_hex_to_rgb_list.
* Add unit tests for rgb_hex_to_rgb_list.
This bumps the somecomfort requirement to 0.2.1 to pull in a change
that makes handling no-fan systems graceful. Adds a test that should
prove it gives us what we want.
If no fan, then fan is always idle and fanmode is None.
This allows you to get every door, window, smoke, etc zone from your security
panel into HA. This uses the live eventing feature of pynx584, which means you
get instantaneous signaling into HA when a door opens or something happens,
which is handy for automating lights on when doors open after dark, etc.
Requires update to pynx584 0.2
This lets you optionally only add thermostats by location or
specific device id, instead of all the thermostats in your
account. This would be helpful if you have two devices in different
houses (i.e vacation home), etc.