Commit Graph

9 Commits (cd26384634170aeead9c0ad4f5a2c8d35215d4c0)

Author SHA1 Message Date
HomeAssistant Azure ee5c1ea3f7 [ci skip] Translation update 2020-09-12 00:05:00 +00:00
HomeAssistant Azure 65b227126d [ci skip] Translation update 2020-09-03 00:06:16 +00:00
HomeAssistant Azure 5ce62c8446 [ci skip] Translation update 2020-09-02 00:03:29 +00:00
J. Nick Koston 4a21b1f589
Update smart_meter_texas to use CoordinatorEntity (#39426) 2020-08-30 16:43:30 +02:00
HomeAssistant Azure 989a040b67 [ci skip] Translation update 2020-08-29 00:03:59 +00:00
Ville Skyttä b4bac0f7a0
Exception chaining and wrapping improvements (#39320)
* Remove unnecessary exception re-wraps

* Preserve exception chains on re-raise

We slap "from cause" to almost all possible cases here. In some cases it
could conceivably be better to do "from None" if we really want to hide
the cause. However those should be in the minority, and "from cause"
should be an improvement over the corresponding raise without a "from"
in all cases anyway.

The only case where we raise from None here is in plex, where the
exception for an original invalid SSL cert is not the root cause for
failure to validate a newly fetched one.

Follow local convention on exception variable names if there is a
consistent one, otherwise `err` to match with majority of codebase.

* Fix mistaken re-wrap in homematicip_cloud/hap.py

Missed the difference between HmipConnectionError and
HmipcConnectionError.

* Do not hide original error on plex new cert validation error

Original is not the cause for the new one, but showing old in the
traceback is useful nevertheless.
2020-08-28 13:50:32 +02:00
HomeAssistant Azure 195d4b6897 [ci skip] Translation update 2020-08-27 00:04:55 +00:00
Graham Wetzler 32db1d1eb2
Improve tests and config flow for Smart Meter Texas (#39089)
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
2020-08-21 19:20:42 +02:00
Graham Wetzler bb164bb32c
Smart Meter Texas integration (#37966)
* Run scaffold script

* Update version

* Bump version

* Initial commit

* Move meter and ESIID to device attributes

* Update internal to hourly due to api limit

* Format with Black

* Fix typo

* Update tests

* Update description

* Disable Pylint error

* Don't commit translations

* Remove meter number from sensor name

* Allow multiple meters per account

* Move data updates to a DataUpdateCoordinator

* Use setdefault to setup the component

* Move strings to const.py

* Fix tests

* Remove meter last updated attribute

* Bump smart-meter-texas version

* Fix logger call

Co-authored-by: J. Nick Koston <nick@koston.org>

* Remove unneeded manifest keys

Co-authored-by: J. Nick Koston <nick@koston.org>

* Remove icon property

Co-authored-by: J. Nick Koston <nick@koston.org>

* Handle instance where user already setup an account

Co-authored-by: J. Nick Koston <nick@koston.org>

* Remove icon constant

* Fix indentation

* Handle config flow errors better

* Use ESIID + meter number as unique ID for sensor

* Update config flow tests to reach 100% coverage

* Avoid reading meters on startup

Cherrypick @bdraco's suggestion

* Run scaffold script

* Update version

* Bump version

* Initial commit

* Move meter and ESIID to device attributes

* Update internal to hourly due to api limit

* Format with Black

* Fix typo

* Update tests

* Update description

* Disable Pylint error

* Don't commit translations

* Remove meter number from sensor name

* Allow multiple meters per account

* Move data updates to a DataUpdateCoordinator

* Use setdefault to setup the component

* Move strings to const.py

* Fix tests

* Remove meter last updated attribute

* Bump smart-meter-texas version

* Fix logger call

Co-authored-by: J. Nick Koston <nick@koston.org>

* Remove unneeded manifest keys

Co-authored-by: J. Nick Koston <nick@koston.org>

* Remove icon property

Co-authored-by: J. Nick Koston <nick@koston.org>

* Handle instance where user already setup an account

Co-authored-by: J. Nick Koston <nick@koston.org>

* Remove icon constant

* Fix indentation

* Handle config flow errors better

* Use ESIID + meter number as unique ID for sensor

* Update config flow tests to reach 100% coverage

* Remove unnecessary try/except block

This checks for the same exception just prior in execution on L51.

* Remove unused return values

* Add tests

* Improve tests and coverage

* Use more pythonic control flow

* Remove all uses of hass.data

Co-authored-by: J. Nick Koston <nick@koston.org>
2020-08-19 13:16:45 -05:00