* Use platform tag to register components on hue SensorManager
instead of a boolean flag to decide between sensor and binary sensor,
so it could be used externally (or to get ready for inclusion of other comps)
* Make new item discovery platform agnostic for SensorManager
instances whenever the volume was requested a division calculation was made
resulting in a TypeError. The volume adjustment from `0-100` to `0-1` is now
calculated during the `update()` method.
* Fix delijn sensor stuck on last passage
If the returned passage is an empty list that means there are
no next passages, so the sensor should be updated accordingly
* Mark the sensor as unavailable instead of emptying data
* use available property
* add available property
instances whenever the volume was requested a division calculation was made
resulting in a TypeError. The volume adjustment from `0-100` to `0-1` is now
calculated during the `update()` method.
* Add limit parameter to service call methods
* Break out prep part of async_call_from_config for use elsewhere
* Minor cleanup
* Fix improper use of asyncio.wait
* Fix state update
Call change listener immediately if its a callback
* Fix exception handling and logging
* Merge Script helper if_running/run_mode parameters into script_mode
- Remove background/blocking _ScriptRun subclasses which are no longer needed.
* Add queued script mode
* Disable timeout when making fully blocking script call
* Don't call change listener when restarting script
This makes restart mode behavior consistent with parallel & queue modes.
* Changes per review
- Call all script services (except script.turn_off) with no time limit.
- Fix handling of lock in _QueuedScriptRun and add comments to make it
clearer how this code works.
* Changes per review 2
- Move cancel shielding "up" from _ScriptRun.async_run to Script.async_run
(and apply to new style scripts only.) This makes sure Script class also
properly handles cancellation which it wasn't doing before.
- In _ScriptRun._async_call_service_step, instead of using script.turn_off
service, just cancel service call and let it handle the cancellation
accordingly.
* Fix bugs
- Add missing call to change listener in Script.async_run
in cancelled path.
- Cancel service task if ServiceRegistry.async_call cancelled.
* Revert last changes to ServiceRegistry.async_call
* Minor Script helper fixes & test improvements
- Don't log asyncio.CancelledError exceptions.
- Make change_listener a public attribute.
- Test overhaul
- Parametrize tests.
- Use common test functions.
- Mock timeout so tests don't need to wait for real time to elapse.
- Add common function for waiting for script action step.
* Add config flow to Freebox
* Add manufacturer in device_tracker info
* Add device_info to sensor + switch
* Add device_info: connections
* Add config_flow test + update .coveragerc
* Typing
* Add device_type icon
* Remove one error log
* Fix pylint
* Add myself as CODEOWNER
* Handle sync in one place
* Separate the Freebox[Router/Device/Sensor] from __init__.py
* Add link step to config flow
* Make temperature sensors auto-discovered
* Use device activity instead of reachablility for device_tracker
* Store token file in .storage
Depending on host if list of Freebox integration on the future without breaking change
* Remove IP sensors + add Freebox router as a device with attrs : IPs, conection type, uptime, version & serial
* Add sensor should_poll=False
* Test typing
* Handle devices with no name
* None is the default for data
* Fix comment
* Use config_entry.unique_id
* Add async_unload_entry with asyncio
* Add and use bunch of data size and rate related constants (#31781)
* Review
* Remove useless "already_configured" error string
* Review : merge 2 device & 2 sensor classes
* Entities from platforms
* Fix unload + add device after setup + clean loggers
* async_add_entities True
* Review
* Use pathlib + refactor get_api
* device_tracker set + tests with CoroutineMock()
* Removing active & reachable from tracker attrs
* Review
* Fix pipeline
* typing
* typing
* typing
* Raise ConfigEntryNotReady when HttpRequestError at setup
* Review
* Multiple Freebox s
* Review: store sensors in router
* Freebox: a sensor story