The default configuration of the mFi controller generates self-signed
certificates which are valid for short periods of time, and which are
regnerated on start or as needed. This makes requests mad. Since most
people will be using the self-signed certificates anyway, add options
to let them choose non-TLS, or unverified connections if they want/need.
This bumps the mficlient requirement to 0.3.0 for proper handling of
verify=False.
Uses the (schiene)[https://pypi.python.org/pypi/schiene/0.14] API to communicate with the webserver of bahn.de
and pulls iformation about a specific connection from the (bahn.de)[http://www.bahn.de/p/view/index.shtml]
webpage. The departure time of the next train for the given connection is shown.
In case of delay, the delay is also shown. Additional `ATTRIBUTES` are used to
inform about e.g. the type of the train, price and if it is ontime.
Usage:
sensor:
platform: deutsche_bahn
from: name_of_start_station
to: name_of_final_station
Problems:
I'm testing it for quite some time, but I have never seen the `ATTRIBUTES` in case
of a delayed train. The `ATTRIBUTES` are directly passed from the `schiene` API. So this
usecase has not been tested yet.
deutsche_bahn ist not supporting the `schiene` api unlike in the swiss_public_transport case.
It's not guaranteed that `schiene` will work forever, infact it can happen that Bahn AG will
intentionally brake the API at some point. In the past Bahn AG has not allways been very supportive
to the opensource community.
This adds tests for the uvc camera module. It's a good thing too,
because I found a few bugs which are fixed here as well:
- Graceful handling of non-integer port
- Failure to take the first host that works when probing host,internalHost
- Failure to detect if neither of them actually work
This also converts the code to only call add_devices once with a listcomp.
Ubiquiti's Unifi WAP infrastructure has a central controller (like mfi and uvc)
that can be queried for client status. This adds a device_tracker module that
can report the state of any client connected to the controller.
This bumps the somecomfort requirement to 0.2.1 to pull in a change
that makes handling no-fan systems graceful. Adds a test that should
prove it gives us what we want.
If no fan, then fan is always idle and fanmode is None.
This allows you to get every door, window, smoke, etc zone from your security
panel into HA. This uses the live eventing feature of pynx584, which means you
get instantaneous signaling into HA when a door opens or something happens,
which is handy for automating lights on when doors open after dark, etc.
Requires update to pynx584 0.2
This is extremely useful if you want to support wemos that are on
another subnet or across a VPN. It also lets you sidestep the discovery
process, which is problematic for a lot of people and situations.
In order for this to work, we need to bump the pywemo requirement to
0.3.10, which includes my changes to make this possible.
WeMo devices can be manually configured by adding a static section to
the config, like this:
switch:
platform: wemo
static:
- 192.168.100.5
- 192.168.100.6