Unfortunately, Ubiquiti changed their (supposedly versioned) API in
3.2.0 which causes us to have to refer to cameras by id instead of
UUID. The firmware for 3.2.x also changed the on-camera login procedures
and snapshot functionality significantly.
This bumps the requirement for uvcclient to 0.9.0, which supports the
newer API and makes the tweaks necessary to interact properly.
* flux platform as a switch
* use track_time_change. broken :(
* use track_utc_time_change instead of track_time_change
* add some basic tests
* use brightness from RGB_to_xy
* config_schema validation
* back to platform schema. what was i doing?
* more broken tests :(
* 644
* fix some time bugs
* add working tests. config validation still not right
* bug fixes and more test cases.
* List entity_ids in config and only react to them
This allows us to define a list of entity_ids in the config to make the
template sensor, binary sensor and switch only react to state changes of
these entities instead of listening to all state changes.
* Forgot to import the track_state_change function
* Changed test for added entity_ids to config
* Use default MATCH_ALL and remove event_listener
* Allow time condition windows to cross midnight.
* Address comments.
Fold _in_time_window back into the time() condition test.
Use specific time values to test the time window.
* Add support for Logentries
Supports sending has events to Logentries web hook endpoint
see logentries.com for more
Inspired by the Splunk component
* bugfix
* fix summary
* fix test
* fix logentries url and tests
* update tests
* mock token
* Bug fixes
* typo
* typo
* fix string splitting
* remove redundant backslash
* Adds MoldIndicator sensor platform
This sensor may be used to get an indication for possible mold growth in rooms.
It calculates the humidity at a pre-calibrated indoor point (wall, window).
* Automatic conversion to Fahrenheit for mold_indicator
* Minor change to critical temp label
* Fixed docstrings and styles
* Minor changes to MoldIndicator implementation
* Added first (non-working) implementation for mold_indicator test
* Small style changes
* Minor improvements to mold_indicator
* Completed unit test for mold indicator
* Fix to moldindicator initialization
* Adds missing period. Now that really matters..
* Adds test for sensor_changed function
"unix" timestamp is number of seconds since Jan 1, 1970 UTC.
This allows scripts that use templates to generate time
deltas in seconds if desired from state attributes such
as last_updated.
Some examples:
timestamp now is
{{ as_timestamp(now) }}
timstamp of last change is
{{ as_timestamp(states.binary_sensor.garage_door.last_changed) }}
seconds since last change is