Commit Graph

9 Commits (5cab319798904d4ef2b2fe7ec0e9eca621a0c94e)

Author SHA1 Message Date
Matthias Urlichs 0121e3cb04 Remove usage of "run_until_complete" (#16617)
* De-run_forever()-ization

* Use asyncio.run (or our own implementation on Python <3.7)
* hass.start is only used by tests
* setup_and_run_hass() is now async
* Add "main" async hass.run method
* move SIGINT handling to helpers/signal.py
  * add flag to .run to disable hass's signal handlers
* Teach async_start and async_stop to not step on each other
  (more than necessary)

* shorten over-long lines

* restore missing "import asyncio"

* move run_asyncio to homeassistant.util.async_

* LOGGER: warn => warning

* Add "force" flag to async_stop

only useful for testing

* Add 'attrs==18.2.0' to requirements_all.txt

Required for keeping requirements_test_all.txt in sync, where it is in
turn required to prevent auto-downgrading "attrs" during "pip install"

* Fixes for mypy

* Fix "mock_signal" fixture

* Revert mistaken edit

* Flake8 fixes

* mypy fixes

* pylint fix

* Revert adding attrs== to requirements_test*.txt

solved by using "pip -c"

* Rename "run" to "async_run", as per calling conventions
2018-09-19 15:40:02 +02:00
Ville Skyttä 55ee8959ba Spelling fixes (#11940) 2018-01-27 11:58:27 -08:00
Pascal Vizeli 2438c6b7c2 Fix attribute entity (#8066)
* Bugfix entity attribute setter

* Fix tests

* Fix tests part 2

* Change filter only None

* Fix tests part 3

* Update entity.py

* Fix tests
2017-06-17 10:03:49 -07:00
Johan Bloemberg e5feeec7a4 Value of 0 should not be considered `unknown`. (#7139)
* Value of 0 should not be considered `unknown`.

* Reflect disconnect state in entity states.

* Due to adding unknown state on disconnect, the amount of reconnects can sometimes be more. Test for at least 2 reconnect attempts.
2017-04-18 20:24:44 -07:00
Johan Bloemberg bd3fbe8363 Upgrade to dsmr_parser 0.8, supporting protocol 3 and 5. (#6600)
* Upgrade to dsmr_parser 0.8, supporting protocol 3 and 5.

* Update tests for new import.
2017-03-14 20:16:43 +01:00
Johan Bloemberg 915a91dc1b DSMR: TCP, reconnecting and V4 CRC support (#5164)
* Add support for TCP connection.

* Implement reconnect logic.

* Actually register connect loop task and fix error handling.

* Fix lint, configure upstream requirement.

* Revert debug logging.

* Explicitly catch connection errors.

* Test reconnect on setup and reconnect after disconnect.

* Style.
2017-01-16 23:56:00 -08:00
Paulus Schoutsen 9eed03108f Run tests on Python 3.6 (#5162)
* Run tests on Python 3.6

* Fix dsmr test

* Fix async util tests

* Fix rest sensor test
2017-01-03 21:33:48 +01:00
Johan Bloemberg 776e53a7f0 Dsmr hourly gas usage. (#4609)
* Hourly rate of Gas consumption. Use proper unknown state.

* Import unknown state constant.

* doh

* Cleanup device add.

* Fix lint.

* Add test for derivative calculation.

* Remove conflict.

* Document and move calculation into update call.
2016-12-03 20:45:42 -08:00
Johan Bloemberg 64cfc4ff02 DSMR sensor (#4309)
* Initial implemenation of DSMR component.

* Fix linting

* Remove protocol V2.2 support until merged upstream.

* Generate requirements using script.

* Use updated dsmr-parser with protocol 2.2 support.

* Add tests.

* Isort and input validation.

* Add entities for gas and actual meter reading. Error handling. Use Throttle.

* Implement non-blocking serial reader.

* Improve logging.

* Merge entities into one, add icons, fix tests for asyncio.

* Add error logging for serial reader.

* Refactoring and documentation.

- refactor asyncio reader task to make sure it stops with HA
- document general principle of this component
- refactor entity reading to be more clear
- remove cruft from split entity implementation

* Use `port` configuration key.

* DSMR V2.2 seems to conflict in explaining which tariff is high and low.

http://www.netbeheernederland.nl/themas/hotspot/hotspot-documenten/?dossierid=11010056&title=Slimme%20meter&onderdeel=Documenten
> DSMR v2.2 Final P1
>> 6.1: table vs table note

    Meter Reading electricity delivered to client normal tariff) in 0,01 kWh - 1-0:1.8.1.255
    Meter Reading electricity delivered to client (low tariff) in 0,01 kWh - 1-0:1.8.2.255

    Note: Tariff code 1 is used for low tariff and tariff code 2 is used for normal tariff.

* Refactor to use asyncio.Protocol instead of loop+queue.

* Fix requirements

* Close transport when HA stops.

* Cleanup.

* Include as dependency for testing (until merged upstream.)

* Fix style.

* Update setup.cfg
2016-11-22 23:03:39 -08:00