* add CONF_STATE_CLASS to const.py
* move to `sensor/__init__.py`
* move to sensor/const.py
* Revert "move to sensor/const.py"
This reverts commit 604d0d066b.
* move it to `sensor/const.py` but import it from `sensor/__init__.py`
* add Modbus
* refactor ModbusRegisterSensor to match the ModbusSwitch interface
* Please pylint, mypy etc.
* Remove PLATFORM.
Co-authored-by: jan Iversen <jancasacondor@gmail.com>
Remove old style configuration from switch.
- The old style configuration allowed a number of illegal
configurations, instead of adding if...log. in setup we
only support the new configuration style.
Add new/changed configuration switch.
Removed verify_state and cleaned configuration to avoid possible
illegal configurations.
* Reuse HA constants for serial configuration.
Reusing HA consts reduces the need for translation.
Sort/group constants in const.
* Change const name ATTR_* to CONF_*
* Correct wrong import
* ATTR_* for service and CONF_* for schemas.
* Revert change to service call.
* Rename CONF_TEMPERATURE -> ATTR_TEMPERATURE
Avoid possible division problem in set_temperature.
* WRITE_COIL uses write_coils in case of an array.
WRITE_REGISTER uses write_register/write_registers depending
on whether value is singular or an array.
WRITE_COIL is modified to be similar and uses
write_coil/write_coils depending on whether value is singular or an
array.
* Update SERVICE_WRITE_COIL to allow list.
* Change modbus configuration to new style.
The old (frozen) configuration is still supported, but when detected a big
warning is issued that it will soon be removed. This allows users to change
their configuration at their pace.
Clean configuration SCHEMAs and move common modbus parts
to MODBUS_SCHEMA (renamed from BASE_SCHEMA).
Add BASE_COMPONENT_SCHEMA to ensure common configuration of components.
All component define e.g. NAME, move these to a common schema.
change components (binary_sensor, sensor, switch) to new config
Add test set for modbus itself (old config and discovery_info).
Add test of devices discovery_info configuration
* Update discovery_info configuration for binary_sensor.
* Update discovery_info configuration for sensor.
* Update discovery_info configuration for switch.
* Review comments.
* update due to change in core
* flake8 problem.
* Correct log message.
* add should_poll property.
* Fix polling for Modbus binary sensor
* Fix polling for Modbus sensor
* Fix polling for Modbus switch
* Fix switch.
* Fix pytest errors.
* Update homeassistant/components/modbus/binary_sensor.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/binary_sensor.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/modbus.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/sensor.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/sensor.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/sensor.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/switch.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/switch.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update homeassistant/components/modbus/switch.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* ToogleEntity -> SwitchEntity and add abastract
* Update homeassistant/components/modbus/switch.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Update tests/components/modbus/test_init.py
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* removed if/else in test.
* Remove other if.
Co-authored-by: Vladimir Zahradnik <vladimir@zahradnik.io>
Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
* Add Modbus cover
* Fix improper commands written for Modbus cover via coil
* Make changes per review comments
* Fix default hub not defined
Since support for multiple hubs was added, the default hub option
was not implemented correctly. Now I added necessary logic to make
it work. First hub in a list will be used as a default hub.
* Move Cover config under Modbus section
* Revert setting up a default hub alias
* Make hub mandatory for Cover
* Add default scan interval
* Read scan_interval from discovery info
* Fix linter error
* Use default scan interval from Cover platform
* Handle polling for Modbus cover directly inside entity
* Move covers under hub config
* Fix for review comment
* Call update() from Cover actuator methods
* Fix time validation
* Rollback modbus to version 0.107.7
Update manifest to not use async.
Rollback entities to sync version.
Keep newer modifications apart from async.
Rollback __init__ to sync version but keep the new functionality.
add async sub directory
Adding the current (not working) version in a sub directory,
to allow easy sharing with a few alfa testers.
The async version are to be updated to use the serial/tcp already
available instead of the flaky pymodbus version. pymodbus is still
needed to encode/decode the messagess.
Update test cases to reflect sync implementation, but
keep the new functionality like e.g. conftest.py.
* do not publish async version
The async version will be made available in a forked repo, until
it is ready to replace the production code.