Solve switch/verify register type convert problem in modbus (#54645)

pull/54734/head
jan iversen 2021-08-16 04:57:37 +02:00 committed by GitHub
parent b2f73b3c69
commit bec42b74fe
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 3 additions and 3 deletions

View File

@ -187,9 +187,9 @@ class BaseSwitch(BasePlatform, ToggleEntity, RestoreEntity):
self._verify_address = config[CONF_VERIFY].get(
CONF_ADDRESS, config[CONF_ADDRESS]
)
self._verify_type = config[CONF_VERIFY].get(
CONF_INPUT_TYPE, convert[config[CONF_WRITE_TYPE]][0]
)
self._verify_type = convert[
config[CONF_VERIFY].get(CONF_INPUT_TYPE, config[CONF_WRITE_TYPE])
][0]
self._state_on = config[CONF_VERIFY].get(CONF_STATE_ON, self.command_on)
self._state_off = config[CONF_VERIFY].get(CONF_STATE_OFF, self._command_off)
else: