Fix ZHA Metering channel formatting method (#36697)

Since zigpy change to support bitmap classes, formatting string was incorrectly generated for the newly joined devices with SmartEnergy metering clusters.
pull/36702/head
Alexei Chetroi 2020-06-11 22:37:07 -04:00 committed by GitHub
parent 419a92db43
commit 8e44d797a3
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 1 additions and 1 deletions

View File

@ -128,7 +128,7 @@ class Metering(ZigbeeChannel):
"demand_formatting", 0xF9
) # 1 digit to the right, 15 digits to the left
r_digits = fmting & 0x07 # digits to the right of decimal point
r_digits = int(fmting & 0x07) # digits to the right of decimal point
l_digits = (fmting >> 3) & 0x0F # digits to the left of decimal point
if l_digits == 0:
l_digits = 15