Fix temperature stepping in Sensibo (#67737)

Co-authored-by: Paulus Schoutsen <paulus@home-assistant.io>
pull/67838/head
G Johansson 2022-03-07 18:55:12 +01:00 committed by Paulus Schoutsen
parent 87492e6b3e
commit 814c96834e
1 changed files with 7 additions and 1 deletions

View File

@ -15,6 +15,8 @@ from homeassistant.helpers.update_coordinator import DataUpdateCoordinator, Upda
from .const import DEFAULT_SCAN_INTERVAL, DOMAIN, LOGGER, TIMEOUT
MAX_POSSIBLE_STEP = 1000
class SensiboDataUpdateCoordinator(DataUpdateCoordinator):
"""A Sensibo Data Update Coordinator."""
@ -74,7 +76,11 @@ class SensiboDataUpdateCoordinator(DataUpdateCoordinator):
.get("values", [0, 1])
)
if temperatures_list:
temperature_step = temperatures_list[1] - temperatures_list[0]
diff = MAX_POSSIBLE_STEP
for i in range(len(temperatures_list) - 1):
if temperatures_list[i + 1] - temperatures_list[i] < diff:
diff = temperatures_list[i + 1] - temperatures_list[i]
temperature_step = diff
active_features = list(ac_states)
full_features = set()