Add binary sensor platform to the Lektrico integration (#129872)
parent
51e691f832
commit
6b90d8ff1a
|
@ -12,6 +12,7 @@ from .coordinator import LektricoDeviceDataUpdateCoordinator
|
|||
|
||||
# List the platforms that charger supports.
|
||||
CHARGERS_PLATFORMS: list[Platform] = [
|
||||
Platform.BINARY_SENSOR,
|
||||
Platform.BUTTON,
|
||||
Platform.NUMBER,
|
||||
Platform.SENSOR,
|
||||
|
|
|
@ -0,0 +1,139 @@
|
|||
"""Support for Lektrico binary sensors entities."""
|
||||
|
||||
from collections.abc import Callable
|
||||
from dataclasses import dataclass
|
||||
from typing import Any
|
||||
|
||||
from homeassistant.components.binary_sensor import (
|
||||
BinarySensorDeviceClass,
|
||||
BinarySensorEntity,
|
||||
BinarySensorEntityDescription,
|
||||
)
|
||||
from homeassistant.const import ATTR_SERIAL_NUMBER, CONF_TYPE, EntityCategory
|
||||
from homeassistant.core import HomeAssistant
|
||||
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||
|
||||
from . import LektricoConfigEntry, LektricoDeviceDataUpdateCoordinator
|
||||
from .entity import LektricoEntity
|
||||
|
||||
|
||||
@dataclass(frozen=True, kw_only=True)
|
||||
class LektricoBinarySensorEntityDescription(BinarySensorEntityDescription):
|
||||
"""Describes Lektrico binary sensor entity."""
|
||||
|
||||
value_fn: Callable[[dict[str, Any]], bool]
|
||||
|
||||
|
||||
BINARY_SENSORS: tuple[LektricoBinarySensorEntityDescription, ...] = (
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="state_e_activated",
|
||||
translation_key="state_e_activated",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["state_e_activated"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="overtemp",
|
||||
translation_key="overtemp",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["overtemp"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="critical_temp",
|
||||
translation_key="critical_temp",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["critical_temp"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="overcurrent",
|
||||
translation_key="overcurrent",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["overcurrent"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="meter_fault",
|
||||
translation_key="meter_fault",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["meter_fault"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="undervoltage",
|
||||
translation_key="undervoltage",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["undervoltage_error"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="overvoltage",
|
||||
translation_key="overvoltage",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["overvoltage_error"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="rcd_error",
|
||||
translation_key="rcd_error",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["rcd_error"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="cp_diode_failure",
|
||||
translation_key="cp_diode_failure",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["cp_diode_failure"]),
|
||||
),
|
||||
LektricoBinarySensorEntityDescription(
|
||||
key="contactor_failure",
|
||||
translation_key="contactor_failure",
|
||||
entity_category=EntityCategory.DIAGNOSTIC,
|
||||
device_class=BinarySensorDeviceClass.PROBLEM,
|
||||
value_fn=lambda data: bool(data["contactor_failure"]),
|
||||
),
|
||||
)
|
||||
|
||||
|
||||
async def async_setup_entry(
|
||||
hass: HomeAssistant,
|
||||
entry: LektricoConfigEntry,
|
||||
async_add_entities: AddEntitiesCallback,
|
||||
) -> None:
|
||||
"""Set up Lektrico binary sensor entities based on a config entry."""
|
||||
coordinator = entry.runtime_data
|
||||
|
||||
async_add_entities(
|
||||
LektricoBinarySensor(
|
||||
description,
|
||||
coordinator,
|
||||
f"{entry.data[CONF_TYPE]}_{entry.data[ATTR_SERIAL_NUMBER]}",
|
||||
)
|
||||
for description in BINARY_SENSORS
|
||||
)
|
||||
|
||||
|
||||
class LektricoBinarySensor(LektricoEntity, BinarySensorEntity):
|
||||
"""Defines a Lektrico binary sensor entity."""
|
||||
|
||||
entity_description: LektricoBinarySensorEntityDescription
|
||||
|
||||
def __init__(
|
||||
self,
|
||||
description: LektricoBinarySensorEntityDescription,
|
||||
coordinator: LektricoDeviceDataUpdateCoordinator,
|
||||
device_name: str,
|
||||
) -> None:
|
||||
"""Initialize Lektrico binary sensor."""
|
||||
super().__init__(coordinator, device_name)
|
||||
self.entity_description = description
|
||||
self._coordinator = coordinator
|
||||
self._attr_unique_id = f"{coordinator.serial_number}_{description.key}"
|
||||
|
||||
@property
|
||||
def is_on(self) -> bool:
|
||||
"""Return the state of the binary sensor."""
|
||||
return self.entity_description.value_fn(self.coordinator.data)
|
|
@ -22,6 +22,38 @@
|
|||
}
|
||||
},
|
||||
"entity": {
|
||||
"binary_sensor": {
|
||||
"state_e_activated": {
|
||||
"name": "Ev error"
|
||||
},
|
||||
"overtemp": {
|
||||
"name": "Thermal throttling"
|
||||
},
|
||||
"critical_temp": {
|
||||
"name": "Overheating"
|
||||
},
|
||||
"overcurrent": {
|
||||
"name": "Overcurrent"
|
||||
},
|
||||
"meter_fault": {
|
||||
"name": "Metering error"
|
||||
},
|
||||
"undervoltage": {
|
||||
"name": "Undervoltage"
|
||||
},
|
||||
"overvoltage": {
|
||||
"name": "Overvoltage"
|
||||
},
|
||||
"rcd_error": {
|
||||
"name": "Rcd error"
|
||||
},
|
||||
"cp_diode_failure": {
|
||||
"name": "Ev diode short"
|
||||
},
|
||||
"contactor_failure": {
|
||||
"name": "Relay contacts welded"
|
||||
}
|
||||
},
|
||||
"button": {
|
||||
"charge_start": {
|
||||
"name": "Charge start"
|
||||
|
|
|
@ -14,5 +14,15 @@
|
|||
"dynamic_current": 32,
|
||||
"user_current": 32,
|
||||
"lb_mode": 0,
|
||||
"require_auth": true
|
||||
"require_auth": true,
|
||||
"state_e_activated": false,
|
||||
"undervoltage_error": true,
|
||||
"rcd_error": false,
|
||||
"meter_fault": false,
|
||||
"overcurrent": false,
|
||||
"overtemp": false,
|
||||
"overvoltage_error": false,
|
||||
"contactor_failure": false,
|
||||
"cp_diode_failure": false,
|
||||
"critical_temp": false
|
||||
}
|
||||
|
|
|
@ -0,0 +1,471 @@
|
|||
# serializer version: 1
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_ev_diode_short-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_ev_diode_short',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Ev diode short',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'cp_diode_failure',
|
||||
'unique_id': '500006_cp_diode_failure',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_ev_diode_short-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Ev diode short',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_ev_diode_short',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_ev_error-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_ev_error',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Ev error',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'state_e_activated',
|
||||
'unique_id': '500006_state_e_activated',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_ev_error-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Ev error',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_ev_error',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_metering_error-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_metering_error',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Metering error',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'meter_fault',
|
||||
'unique_id': '500006_meter_fault',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_metering_error-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Metering error',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_metering_error',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_overcurrent-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_overcurrent',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Overcurrent',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'overcurrent',
|
||||
'unique_id': '500006_overcurrent',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_overcurrent-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Overcurrent',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_overcurrent',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_overheating-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_overheating',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Overheating',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'critical_temp',
|
||||
'unique_id': '500006_critical_temp',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_overheating-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Overheating',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_overheating',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_overvoltage-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_overvoltage',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Overvoltage',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'overvoltage',
|
||||
'unique_id': '500006_overvoltage',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_overvoltage-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Overvoltage',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_overvoltage',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_rcd_error-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_rcd_error',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Rcd error',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'rcd_error',
|
||||
'unique_id': '500006_rcd_error',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_rcd_error-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Rcd error',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_rcd_error',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_relay_contacts_welded-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_relay_contacts_welded',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Relay contacts welded',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'contactor_failure',
|
||||
'unique_id': '500006_contactor_failure',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_relay_contacts_welded-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Relay contacts welded',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_relay_contacts_welded',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_thermal_throttling-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_thermal_throttling',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Thermal throttling',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'overtemp',
|
||||
'unique_id': '500006_overtemp',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_thermal_throttling-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Thermal throttling',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_thermal_throttling',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'off',
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_undervoltage-entry]
|
||||
EntityRegistryEntrySnapshot({
|
||||
'aliases': set({
|
||||
}),
|
||||
'area_id': None,
|
||||
'capabilities': None,
|
||||
'config_entry_id': <ANY>,
|
||||
'device_class': None,
|
||||
'device_id': <ANY>,
|
||||
'disabled_by': None,
|
||||
'domain': 'binary_sensor',
|
||||
'entity_category': <EntityCategory.DIAGNOSTIC: 'diagnostic'>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_undervoltage',
|
||||
'has_entity_name': True,
|
||||
'hidden_by': None,
|
||||
'icon': None,
|
||||
'id': <ANY>,
|
||||
'labels': set({
|
||||
}),
|
||||
'name': None,
|
||||
'options': dict({
|
||||
}),
|
||||
'original_device_class': <BinarySensorDeviceClass.PROBLEM: 'problem'>,
|
||||
'original_icon': None,
|
||||
'original_name': 'Undervoltage',
|
||||
'platform': 'lektrico',
|
||||
'previous_unique_id': None,
|
||||
'supported_features': 0,
|
||||
'translation_key': 'undervoltage',
|
||||
'unique_id': '500006_undervoltage',
|
||||
'unit_of_measurement': None,
|
||||
})
|
||||
# ---
|
||||
# name: test_all_entities[binary_sensor.1p7k_500006_undervoltage-state]
|
||||
StateSnapshot({
|
||||
'attributes': ReadOnlyDict({
|
||||
'device_class': 'problem',
|
||||
'friendly_name': '1p7k_500006 Undervoltage',
|
||||
}),
|
||||
'context': <ANY>,
|
||||
'entity_id': 'binary_sensor.1p7k_500006_undervoltage',
|
||||
'last_changed': <ANY>,
|
||||
'last_reported': <ANY>,
|
||||
'last_updated': <ANY>,
|
||||
'state': 'on',
|
||||
})
|
||||
# ---
|
|
@ -0,0 +1,32 @@
|
|||
"""Tests for the Lektrico binary sensor platform."""
|
||||
|
||||
from unittest.mock import AsyncMock, patch
|
||||
|
||||
from syrupy import SnapshotAssertion
|
||||
|
||||
from homeassistant.const import Platform
|
||||
from homeassistant.core import HomeAssistant
|
||||
from homeassistant.helpers import entity_registry as er
|
||||
|
||||
from . import setup_integration
|
||||
|
||||
from tests.common import MockConfigEntry, snapshot_platform
|
||||
|
||||
|
||||
async def test_all_entities(
|
||||
hass: HomeAssistant,
|
||||
snapshot: SnapshotAssertion,
|
||||
mock_device: AsyncMock,
|
||||
mock_config_entry: MockConfigEntry,
|
||||
entity_registry: er.EntityRegistry,
|
||||
) -> None:
|
||||
"""Test all entities."""
|
||||
|
||||
with patch.multiple(
|
||||
"homeassistant.components.lektrico",
|
||||
CHARGERS_PLATFORMS=[Platform.BINARY_SENSOR],
|
||||
LB_DEVICES_PLATFORMS=[Platform.BINARY_SENSOR],
|
||||
):
|
||||
await setup_integration(hass, mock_config_entry)
|
||||
|
||||
await snapshot_platform(hass, entity_registry, snapshot, mock_config_entry.entry_id)
|
Loading…
Reference in New Issue