Remove last_reset attribute from dsmr sensors (#54699)
parent
61ab2b0c60
commit
35389a6d28
|
@ -5,7 +5,10 @@ import logging
|
|||
|
||||
from dsmr_parser import obis_references
|
||||
|
||||
from homeassistant.components.sensor import STATE_CLASS_MEASUREMENT
|
||||
from homeassistant.components.sensor import (
|
||||
STATE_CLASS_MEASUREMENT,
|
||||
STATE_CLASS_TOTAL_INCREASING,
|
||||
)
|
||||
from homeassistant.const import (
|
||||
DEVICE_CLASS_CURRENT,
|
||||
DEVICE_CLASS_ENERGY,
|
||||
|
@ -13,7 +16,6 @@ from homeassistant.const import (
|
|||
DEVICE_CLASS_POWER,
|
||||
DEVICE_CLASS_VOLTAGE,
|
||||
)
|
||||
from homeassistant.util import dt
|
||||
|
||||
from .models import DSMRSensorEntityDescription
|
||||
|
||||
|
@ -67,32 +69,28 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
name="Energy Consumption (tarif 1)",
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
force_update=True,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.ELECTRICITY_USED_TARIFF_2,
|
||||
name="Energy Consumption (tarif 2)",
|
||||
force_update=True,
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.ELECTRICITY_DELIVERED_TARIFF_1,
|
||||
name="Energy Production (tarif 1)",
|
||||
force_update=True,
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.ELECTRICITY_DELIVERED_TARIFF_2,
|
||||
name="Energy Production (tarif 2)",
|
||||
force_update=True,
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE,
|
||||
|
@ -229,8 +227,7 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
dsmr_versions={"5L"},
|
||||
force_update=True,
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.LUXEMBOURG_ELECTRICITY_DELIVERED_TARIFF_GLOBAL,
|
||||
|
@ -238,8 +235,7 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
dsmr_versions={"5L"},
|
||||
force_update=True,
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.ELECTRICITY_IMPORTED_TOTAL,
|
||||
|
@ -247,8 +243,7 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
dsmr_versions={"2.2", "4", "5", "5B"},
|
||||
force_update=True,
|
||||
device_class=DEVICE_CLASS_ENERGY,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.HOURLY_GAS_METER_READING,
|
||||
|
@ -258,8 +253,7 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
force_update=True,
|
||||
icon="mdi:fire",
|
||||
device_class=DEVICE_CLASS_GAS,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.BELGIUM_HOURLY_GAS_METER_READING,
|
||||
|
@ -269,8 +263,7 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
force_update=True,
|
||||
icon="mdi:fire",
|
||||
device_class=DEVICE_CLASS_GAS,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
DSMRSensorEntityDescription(
|
||||
key=obis_references.GAS_METER_READING,
|
||||
|
@ -280,7 +273,6 @@ SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|||
force_update=True,
|
||||
icon="mdi:fire",
|
||||
device_class=DEVICE_CLASS_GAS,
|
||||
last_reset=dt.utc_from_timestamp(0),
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
state_class=STATE_CLASS_TOTAL_INCREASING,
|
||||
),
|
||||
)
|
||||
|
|
|
@ -18,6 +18,7 @@ from homeassistant.components.sensor import (
|
|||
ATTR_STATE_CLASS,
|
||||
DOMAIN as SENSOR_DOMAIN,
|
||||
STATE_CLASS_MEASUREMENT,
|
||||
STATE_CLASS_TOTAL_INCREASING,
|
||||
)
|
||||
from homeassistant.const import (
|
||||
ATTR_DEVICE_CLASS,
|
||||
|
@ -167,8 +168,10 @@ async def test_default_setup(hass, dsmr_connection_fixture):
|
|||
assert gas_consumption.state == "745.695"
|
||||
assert gas_consumption.attributes.get(ATTR_DEVICE_CLASS) == DEVICE_CLASS_GAS
|
||||
assert gas_consumption.attributes.get(ATTR_ICON) == "mdi:fire"
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is not None
|
||||
assert gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_MEASUREMENT
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is None
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_TOTAL_INCREASING
|
||||
)
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_UNIT_OF_MEASUREMENT) == VOLUME_CUBIC_METERS
|
||||
)
|
||||
|
@ -267,8 +270,10 @@ async def test_v4_meter(hass, dsmr_connection_fixture):
|
|||
assert gas_consumption.attributes.get(ATTR_DEVICE_CLASS) == DEVICE_CLASS_GAS
|
||||
assert gas_consumption.attributes.get("unit_of_measurement") == VOLUME_CUBIC_METERS
|
||||
assert gas_consumption.attributes.get(ATTR_ICON) == "mdi:fire"
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is not None
|
||||
assert gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_MEASUREMENT
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is None
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_TOTAL_INCREASING
|
||||
)
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_UNIT_OF_MEASUREMENT) == VOLUME_CUBIC_METERS
|
||||
)
|
||||
|
@ -337,8 +342,10 @@ async def test_v5_meter(hass, dsmr_connection_fixture):
|
|||
assert gas_consumption.state == "745.695"
|
||||
assert gas_consumption.attributes.get(ATTR_DEVICE_CLASS) == DEVICE_CLASS_GAS
|
||||
assert gas_consumption.attributes.get(ATTR_ICON) == "mdi:fire"
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is not None
|
||||
assert gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_MEASUREMENT
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is None
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_TOTAL_INCREASING
|
||||
)
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_UNIT_OF_MEASUREMENT) == VOLUME_CUBIC_METERS
|
||||
)
|
||||
|
@ -403,8 +410,8 @@ async def test_luxembourg_meter(hass, dsmr_connection_fixture):
|
|||
assert power_tariff.state == "123.456"
|
||||
assert power_tariff.attributes.get(ATTR_DEVICE_CLASS) == DEVICE_CLASS_ENERGY
|
||||
assert power_tariff.attributes.get(ATTR_ICON) is None
|
||||
assert power_tariff.attributes.get(ATTR_LAST_RESET) is not None
|
||||
assert power_tariff.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_MEASUREMENT
|
||||
assert power_tariff.attributes.get(ATTR_LAST_RESET) is None
|
||||
assert power_tariff.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_TOTAL_INCREASING
|
||||
assert (
|
||||
power_tariff.attributes.get(ATTR_UNIT_OF_MEASUREMENT) == ENERGY_KILO_WATT_HOUR
|
||||
)
|
||||
|
@ -418,8 +425,10 @@ async def test_luxembourg_meter(hass, dsmr_connection_fixture):
|
|||
assert gas_consumption.state == "745.695"
|
||||
assert gas_consumption.attributes.get(ATTR_DEVICE_CLASS) == DEVICE_CLASS_GAS
|
||||
assert gas_consumption.attributes.get(ATTR_ICON) == "mdi:fire"
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is not None
|
||||
assert gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_MEASUREMENT
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is None
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_TOTAL_INCREASING
|
||||
)
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_UNIT_OF_MEASUREMENT) == VOLUME_CUBIC_METERS
|
||||
)
|
||||
|
@ -488,8 +497,10 @@ async def test_belgian_meter(hass, dsmr_connection_fixture):
|
|||
assert gas_consumption.state == "745.695"
|
||||
assert gas_consumption.attributes.get(ATTR_DEVICE_CLASS) is DEVICE_CLASS_GAS
|
||||
assert gas_consumption.attributes.get(ATTR_ICON) == "mdi:fire"
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is not None
|
||||
assert gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_MEASUREMENT
|
||||
assert gas_consumption.attributes.get(ATTR_LAST_RESET) is None
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_STATE_CLASS) == STATE_CLASS_TOTAL_INCREASING
|
||||
)
|
||||
assert (
|
||||
gas_consumption.attributes.get(ATTR_UNIT_OF_MEASUREMENT) == VOLUME_CUBIC_METERS
|
||||
)
|
||||
|
|
Loading…