Add Particulate Matter 2.5 of ZCL concentration clusters to ZHA component (#72826)
* Add Particulate Matter 2.5 of ZCL concentration clusters to ZHA component * Fixed black and flake8 testpull/72866/head
parent
2ba45a9f99
commit
321394d3e2
|
@ -128,6 +128,18 @@ class CarbonDioxideConcentration(ZigbeeChannel):
|
|||
]
|
||||
|
||||
|
||||
@registries.ZIGBEE_CHANNEL_REGISTRY.register(measurement.PM25.cluster_id)
|
||||
class PM25(ZigbeeChannel):
|
||||
"""Particulate Matter 2.5 microns or less measurement channel."""
|
||||
|
||||
REPORT_CONFIG = [
|
||||
{
|
||||
"attr": "measured_value",
|
||||
"config": (REPORT_CONFIG_MIN_INT, REPORT_CONFIG_MAX_INT, 0.1),
|
||||
}
|
||||
]
|
||||
|
||||
|
||||
@registries.ZIGBEE_CHANNEL_REGISTRY.register(
|
||||
measurement.FormaldehydeConcentration.cluster_id
|
||||
)
|
||||
|
|
|
@ -607,6 +607,17 @@ class PPBVOCLevel(Sensor):
|
|||
_unit = CONCENTRATION_PARTS_PER_BILLION
|
||||
|
||||
|
||||
@MULTI_MATCH(channel_names="pm25")
|
||||
class PM25(Sensor):
|
||||
"""Particulate Matter 2.5 microns or less sensor."""
|
||||
|
||||
SENSOR_ATTR = "measured_value"
|
||||
_attr_state_class: SensorStateClass = SensorStateClass.MEASUREMENT
|
||||
_decimals = 0
|
||||
_multiplier = 1
|
||||
_unit = CONCENTRATION_MICROGRAMS_PER_CUBIC_METER
|
||||
|
||||
|
||||
@MULTI_MATCH(channel_names="formaldehyde_concentration")
|
||||
class FormaldehydeConcentration(Sensor):
|
||||
"""Formaldehyde Concentration sensor."""
|
||||
|
|
Loading…