Fix Matter climate platform attributes when dedicated OnOff attribute is off (#126286)
parent
7658ed8eaa
commit
2322d071e4
|
@ -190,48 +190,56 @@ class MatterClimate(MatterEntity, ClimateEntity):
|
|||
# if the mains power is off - treat it as if the HVAC mode is off
|
||||
self._attr_hvac_mode = HVACMode.OFF
|
||||
self._attr_hvac_action = None
|
||||
return
|
||||
|
||||
# update hvac_mode from SystemMode
|
||||
system_mode_value = int(
|
||||
self.get_matter_attribute_value(clusters.Thermostat.Attributes.SystemMode)
|
||||
)
|
||||
match system_mode_value:
|
||||
case SystemModeEnum.kAuto:
|
||||
self._attr_hvac_mode = HVACMode.HEAT_COOL
|
||||
case SystemModeEnum.kDry:
|
||||
self._attr_hvac_mode = HVACMode.DRY
|
||||
case SystemModeEnum.kFanOnly:
|
||||
self._attr_hvac_mode = HVACMode.FAN_ONLY
|
||||
case SystemModeEnum.kCool | SystemModeEnum.kPrecooling:
|
||||
self._attr_hvac_mode = HVACMode.COOL
|
||||
case SystemModeEnum.kHeat | SystemModeEnum.kEmergencyHeat:
|
||||
self._attr_hvac_mode = HVACMode.HEAT
|
||||
case SystemModeEnum.kFanOnly:
|
||||
self._attr_hvac_mode = HVACMode.FAN_ONLY
|
||||
case SystemModeEnum.kDry:
|
||||
self._attr_hvac_mode = HVACMode.DRY
|
||||
case _:
|
||||
self._attr_hvac_mode = HVACMode.OFF
|
||||
# running state is an optional attribute
|
||||
# which we map to hvac_action if it exists (its value is not None)
|
||||
self._attr_hvac_action = None
|
||||
if running_state_value := self.get_matter_attribute_value(
|
||||
clusters.Thermostat.Attributes.ThermostatRunningState
|
||||
):
|
||||
match running_state_value:
|
||||
case ThermostatRunningState.Heat | ThermostatRunningState.HeatStage2:
|
||||
self._attr_hvac_action = HVACAction.HEATING
|
||||
case ThermostatRunningState.Cool | ThermostatRunningState.CoolStage2:
|
||||
self._attr_hvac_action = HVACAction.COOLING
|
||||
case (
|
||||
ThermostatRunningState.Fan
|
||||
| ThermostatRunningState.FanStage2
|
||||
| ThermostatRunningState.FanStage3
|
||||
):
|
||||
self._attr_hvac_action = HVACAction.FAN
|
||||
else:
|
||||
# update hvac_mode from SystemMode
|
||||
system_mode_value = int(
|
||||
self.get_matter_attribute_value(
|
||||
clusters.Thermostat.Attributes.SystemMode
|
||||
)
|
||||
)
|
||||
match system_mode_value:
|
||||
case SystemModeEnum.kAuto:
|
||||
self._attr_hvac_mode = HVACMode.HEAT_COOL
|
||||
case SystemModeEnum.kDry:
|
||||
self._attr_hvac_mode = HVACMode.DRY
|
||||
case SystemModeEnum.kFanOnly:
|
||||
self._attr_hvac_mode = HVACMode.FAN_ONLY
|
||||
case SystemModeEnum.kCool | SystemModeEnum.kPrecooling:
|
||||
self._attr_hvac_mode = HVACMode.COOL
|
||||
case SystemModeEnum.kHeat | SystemModeEnum.kEmergencyHeat:
|
||||
self._attr_hvac_mode = HVACMode.HEAT
|
||||
case SystemModeEnum.kFanOnly:
|
||||
self._attr_hvac_mode = HVACMode.FAN_ONLY
|
||||
case SystemModeEnum.kDry:
|
||||
self._attr_hvac_mode = HVACMode.DRY
|
||||
case _:
|
||||
self._attr_hvac_action = HVACAction.OFF
|
||||
self._attr_hvac_mode = HVACMode.OFF
|
||||
# running state is an optional attribute
|
||||
# which we map to hvac_action if it exists (its value is not None)
|
||||
self._attr_hvac_action = None
|
||||
if running_state_value := self.get_matter_attribute_value(
|
||||
clusters.Thermostat.Attributes.ThermostatRunningState
|
||||
):
|
||||
match running_state_value:
|
||||
case (
|
||||
ThermostatRunningState.Heat
|
||||
| ThermostatRunningState.HeatStage2
|
||||
):
|
||||
self._attr_hvac_action = HVACAction.HEATING
|
||||
case (
|
||||
ThermostatRunningState.Cool
|
||||
| ThermostatRunningState.CoolStage2
|
||||
):
|
||||
self._attr_hvac_action = HVACAction.COOLING
|
||||
case (
|
||||
ThermostatRunningState.Fan
|
||||
| ThermostatRunningState.FanStage2
|
||||
| ThermostatRunningState.FanStage3
|
||||
):
|
||||
self._attr_hvac_action = HVACAction.FAN
|
||||
case _:
|
||||
self._attr_hvac_action = HVACAction.OFF
|
||||
|
||||
# update target temperature high/low
|
||||
supports_range = (
|
||||
self._attr_supported_features
|
||||
|
|
Loading…